Industrial expansion tank static pressure tester supplier
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Standards
The system supports compliance with major automotive engineering standards:
VW TL889 (4.1) – Volkswagen Group technical specification for interior and related component functional performance.
ESDG93-8A080-AA (3.6) – Ford engineering specification for component functionality and reliability.
GMW15310 (3.2.1.2) – General Motors global standard for material and component performance testing.
QV17004D (3.2.6) – BMW group specification for system component functionality and durability.
Parameters
| Parameter Category | Details |
|---|---|
| Test Bench Dimensions | 2200 × 2240 × 1550 mm (W × H × D) |
| Chamber Dimensions | 1000 × 800 × 1000 mm (W × H × D) |
| Rated Power | 9.5 kW |
| Test Medium | Glycol/Water |
| Pressure Range | 0 … 5 bar |
| Flow Rate per Sample | 0 … 8 l/h |
| Pressure Type | Static |
| Test Medium Temperature Range | 25 … +150°C |
| Environmental Temperature Range | 25 … +150°C |
| Test Channels | 6 |
Features
Designed specifically for static pressure testing of expansion tanks.
Static pressure adjustable from 0 up to 5 bar.
Individual sample flow rate controllable from 0 to 8 l/h.
Explosion protection level 1 due to indirect chamber heating.
Automatic leak detection and leak testing with fail-safe shutdown of defective samples.
Automatic control of liquid level during testing.
Accessories
Indirectly heated test chamber
Flow control units for each sample
Leak detection sensors and safety interlocks
Liquid level monitoring and control system
Control unit with Windows/LabVIEW interface (optional for data logging)
Sample mounting brackets for expansion tanks
Test Procedures
Ensure the test area is clear and safe for operation.
Connect the system to the 9.5 kW power supply.
Fill the chamber and sample lines with glycol/water mixture.
Mount expansion tank samples in the test chamber.
Set the static pressure (0–5 bar) and flow rate (0–8 l/h) for each sample.
Activate the test system and indirect heating if required.
Monitor pressure, flow, and leak detection sensors throughout the test.
Automatically shut down any failed samples.
Record all test results for quality control or validation purposes.
After testing, safely drain the medium and allow the system to cool before removing samples.
Maintenance Information
Inspect sample mounting brackets, pressure sensors, and leak detection units before each test.
Verify flow control devices and chamber seals for proper operation.
Periodically calibrate pressure sensors and temperature controllers.
Clean the chamber and fluid circuits to prevent contamination.
Replace worn or defective components to maintain safe and accurate operation.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Safety Helmets Acceleration Impact & Penetration Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard GB/T 2812: Safety Helmets (China National Standard) Equivalent Compliance: ISO 6... | |
| Micro Rapid Closed Cup Flash Point Tester | Pensky Martens ASTM D93 | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards (1)SN/T 3077.1-2012: Chemicals—Determination of flash point&... | |
| Textile Fiber Micron Measurement Instrument ISO Standard | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Features (1) Broad Measurement Range: Airflow-based micronaire range 2.0&nda... | |
| Guidewire Pushing Force Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications The guidewire pushing force tester is a precision testing tool in the medical... | |
| Yellowing resistance chamber | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applicable standards HG/T3986. ASTM D1748. etc. Scope of application Test method for det... |