Equipment for Overcharge, Short Circuit, and Thermal Runaway
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Standards
The pressure vessel complies with the following standards:
(1) UL 9540A:2025 – Standard for Testing Thermal Runaway Fire Propagation in Battery Energy Storage Systems
(2) PV8450 – Battery Thermal Runaway Test Method
Parameters
| Item | Specification |
|---|---|
| Working Pressure | ≥ 3 MPa, equipped with safety valve for automatic pressure relief |
| Vessel Temperature Resistance | > 1200 °C |
| View Window | Diameter 5–25 cm |
| Thomas Sampling Pump | Adjustable manual exhaust, capable of achieving -90 kPa vacuum |
| Control Cabinet | Standard 19-inch touchscreen, metal frame |
| Environmental Configuration | External nitrogen achieves oxygen concentration <1% |
| Backup Gas Source | Nitrogen ≥ 99.99% purity |
| Power Supply | AC 220 V, 50/60 Hz, 10 A |
Features
Customizable Stainless Steel Vessel
Sealed chamber made of 304 stainless steel; test volume and dimensions can be tailored to specific applications.
Multi-Functional Interfaces
Flanged connection plates with specialized fittings allow for temperature, voltage, heating, and overcurrent connections.
Vacuum and Nitrogen Filling Capability
Achieves oxygen concentration below 1% to simulate inert test environments.
Weighing Platform Integration
Optional platform with load sensors enables mass loss monitoring during thermal events.
Safe and Easy Cell Handling
Swing door with locking screws ensures airtight seal; movable metal cell holder allows stable sample placement.
Pressure Monitoring
Customizable range via high-precision sensors to capture vessel internal pressure dynamics.
Multi-Channel Data Acquisition
12 temperature channels (expandable), 2 voltage channels for real-time battery voltage monitoring.
Gas Flow Control
Manual ball valves and solenoid valves protect sensors and prevent gas leakage.
Advanced Control Cabinet
19-inch touchscreen in a metal frame with electrostatic spray coating, high-temperature baking process for durability, easy cleaning, and aesthetic appearance.
Automated Data Monitoring
Siemens PLC and analog modules, integrated with LabVIEW software, monitor temperature, pressure, and oxygen concentration in real time, and store data for later analysis.
Report Generation
Test data can be exported as Excel, Word, or PDF files for documentation and further analysis.
Accessories
(1) Thomas sampling pump
(2) Safety valves and pressure sensors
(3) Temperature and voltage sensor interfaces
(4) Nitrogen filling system
(5) Weighing platform with load sensors
(6) Film heating interface
(7) Overcurrent protection interface
(8) Standard electrical control cabinet with touchscreen and PLC
Test Procedures
Cell Installation: Place battery cells in the vessel on the movable holder and lock the chamber door.
System Preparation: Connect external nitrogen supply and set oxygen concentration below 1% if required.
Parameter Setup: Configure temperature, pressure, and voltage monitoring channels via the touchscreen.
Initiate Test: Activate PLC control system to begin thermal runaway simulation.
Data Monitoring: Record pressure, temperature, oxygen levels, and cell voltage in real time; optional mass loss measurement.
Data Storage and Report Generation: Export all test data and results in Excel, Word, or PDF format.
Post-Test Procedures: Vent the vessel, safely remove battery cells, and inspect the chamber and sensors for next use.
Maintenance Information
Regularly inspect all valves, fittings, and flanged connections for tightness and integrity.
Calibrate temperature and pressure sensors periodically to ensure accurate measurements.
Clean the interior vessel and viewing window to maintain visibility and prevent contamination.
Verify nitrogen supply system and vacuum pump operation before each test.
Backup all test data and system logs to secure storage for traceability and compliance verification.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Cookware scratch resistance testing machine for non-stick coating | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards (1) BS7069 Annex A.3 – Scratch resistance test method for non-stick cookwa... | |
| Metal Bone Screws Self - tapping Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard ISO 6475: Implants for surgery – Wear of total hip-joint prostheses ASTM F... | |
| Computer-controlled Helmet Impact Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com A computer-controlled helmet impact tester is an instrument used to test the impact resista... | |
| Catheter Airflow Resistance Tester ISO & ASTM Standard | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Catheter Airflow Resistance Tester is a precision testing instrument spec... | |
| 45 Degree Flammability Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The 45° flammability tester consists of a control system and a combustion chamber. The ... |