High-Precision Thermal Constants Testing Equipment
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Standards
The analyzer supports multiple internationally recognized test methods and standards, including:
(1) ISO 22007-2: Plastics — Determination of thermal conductivity and thermal diffusivity — Transient plane heat source method
(2) ISO 22007-7: Plastics — Determination of thermal conductivity and thermal diffusivity using transient plane heat source
(3) GB/T 32064: Transient plane heat source method for thermal conductivity and thermal diffusivity of building materials
(4) ASTM E3088: Standard test method for determination of thermal conductivity and thermal diffusivity using the transient plane source method
(5) ASTM D7896: Transient hot-wire method for thermal conductivity, thermal diffusivity, and volumetric heat capacity of liquids
(6) ASTM D5334: Transient line-source probe method
(7) ASTM D5930: Determination of thermal conductivity of plastics by transient line-source technique
(8) IEEE 442: Soil thermal resistivity measurement
Parameters
| Method | TPS | THW | MTPS | THS | TLS |
|---|---|---|---|---|---|
| Applicable Materials | Solids, pastes, powders | Liquids, phase-change materials | Solids, pastes, powders | Solid rectangular samples | Soil, pastes, polymers |
| Measurement Mode | 3D bulk, anisotropic, plate, thin film, 1D | Bulk | 3D bulk, anisotropic, plate, 1D | Bulk, anisotropic | Bulk |
| Thermal Conductivity (W/m·K) | 0.005–2000 | 0.01–2 | 0.03–500 | 0.01–2 | — |
| Thermal Diffusivity (mm²/s) | 0.01–1200 | Up to 0.5 | 0.01–300 | Up to 0.5 | — |
| Volumetric Heat Capacity (MJ/m³·K) | Up to 5 | Up to 5 | Up to 5 | Up to 5 | — |
| Thermal Effusivity (W·s½/m²·K) | 5–60000 | Not applicable | 20–40000 | Not applicable | — |
| Contact Thermal Resistance (m²·K/W) | Measured | Not applicable | Measured | Not applicable | Not applicable |
| Sample Thickness (mm)* | ≥0.01 | — | ≥0.1 | — | — |
| Test Time (s) | 0.25–2560 | 1 | 0.25–2560 | 0.25–2560 | 180 |
| Accuracy (Thermal Conductivity) | 3% | 2% | 5% | 5% | 5% |
| Repeatability (Thermal Conductivity) | 1% | 1% | 2% | 2% | 2% |
| Temperature Range (°C)** | 0 to 300 / up to 750 or 1000 | 10 to 200 | 0 to 100 / −50 to 200 | −75 to 300 | −40 to 100 |
| Sample Configuration | Symmetric / asymmetric | Insert type | Asymmetric (single-sided) | Symmetric / asymmetric | Insert type |
Features
Supports multiple transient methods within one integrated system
Measures absolute thermal conductivity, thermal diffusivity, specific heat, and thermal effusivity
Suitable for solids, liquids, pastes, powders, and soil samples
Wide thermal conductivity and temperature measurement ranges
Direct measurement of sensor–sample contact thermal resistance for improved accuracy
Accessories
(1) Transient plane heat source (TPS) sensors
(2) Transient hot-wire (THW) sensors
(3) Modified transient plane source (MTPS) sensors
(4) Transient hot strip (THS) sensors
(5) Transient line source (TLS) probes
(6) Sample holders for solid, liquid, and soil configurations
Test Procedures
Select the appropriate measurement method based on sample type and test requirements.
Prepare and position the sample according to the selected method and configuration.
Place the corresponding sensor in contact with or within the sample as required.
Set test parameters such as temperature range and measurement time.
Initiate the test; transient thermal signals are generated and recorded automatically.
The system calculates thermal conductivity, thermal diffusivity, specific heat, and related properties based on the acquired data.
Maintenance Information
Keep all sensors clean and free from surface contamination to ensure stable contact conditions.
Periodically inspect sensor surfaces for wear or damage, especially when testing rough samples.
Verify calibration and system performance at regular intervals using reference materials.
Store sensors and probes in protective containers when not in use to prevent mechanical damage.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| fabric wet adhesion performance tester | Product Overview The Fabric Wet Adhesion Performance Tester is a precision instrument designed to evaluate the adhesion behavior of clothing fab... | |
| Battery combustion tester | The Battery Combustion Tester is designed for safety evaluation of lithium-ion batteries by simulating direct exposure to flame jet combustion unde... | |
| Vacuum leak tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Vacuum Decay Leak Tester specializes in the detection of leaks in ampoules, vials, injectio... | |
| Cloth Bound Water Release Rate Assessment System | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The tester is suitable for: (1) Apparel and sportswear R&D: assessing qui... | |
| Qinsun SUNTEST Weathering Instruments | Whats/App: +86 156 1874 6768 Web: standard-groups.com A practical desktop xenon lamp equipment with various accessories, customized to meet your ... |
Похожие товары
| Benchtop Thermal Conductivity Tester for Insulation Materials | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The instrument complies with a... | |
| High-Accuracy Guarded Heat Flow Meter Thermal Conductivity Measurement System | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The instrument is designed and... | |
| Heat Flow Method for Thermal Conductivity Measurement | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The instrument complies with a... | |
| Benchtop Thermal Conductivity Tester | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The instrument is designed and... | |
| Guarded Heat Flow Measurement System | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ASTM E1530: Standard Test Meth... |