Vacuum Cleaner Air Performance Testing Equipment (Type A Pressure Equalization Chamber)
Whats/App: +86 156 1874 6768
Web: standard-groups.com
TheVacuum Cleaner Air Performance Testing Equipment (Type A Pressure Equalization Chamber)is designed to measure the airflow performance of vacuum cleaners and vacuum cleaner motors with airflow below 40 L/min. You use this system to evaluate key air performance parameters under standardized conditions defined by Type A pressure equalization chamber requirements. Manufactured in compliance with international and national standards, the equipment provides accurate, repeatable, and comparable test results for airflow, suction power, and efficiency. Test data can be automatically recorded and exported via USB, making it suitable for both production and laboratory environments.
Applications
Air performance testing of complete vacuum cleaners
Performance evaluation of handheld vacuum cleaners
Airflow and suction testing of vacuum cleaner motors
Product development and performance benchmarking
Type testing and routine inspection in manufacturing
Verification testing by third-party laboratories
Standards
IEC 60312-1: Vacuum Cleaners for Household Use – Methods for Measuring the Performance – Part 1: Dry Vacuum Cleaners
GB/T 20291.1: Household and Similar Electrical Appliances – Vacuum Cleaners – Part 1: Methods for Measuring Performance
IEC 62885-2: Surface Cleaning Appliances – Part 2: Dry Vacuum Cleaners for Household or Similar Use – Methods for Measuring the Performance
Type A Pressure Equalization Chamber Designas specified in IEC and GB standards
Features
You can perform airflow testing using a standardized Type A pressure equalization chamber
Stepless electric throttle valve allows precise airflow adjustment
Industrial control computer ensures stable data acquisition and processing
Supports simultaneous measurement of electrical and air performance parameters
Suitable for both complete vacuum cleaners and vacuum motors
USB data export simplifies test record storage and reporting
Compact layout with professional laboratory-grade construction
Technical Parameters
| Item | Specification |
|---|---|
| Adjustment Method | Electric throttle valve with stepless speed regulation |
| Pressure Chamber Dimensions | 460×460×250 mm |
| Control Mode | 17-inch industrial control computer display |
| Tester Type | Vacuum cleaner parameter tester |
| Test Voltage | AC/DC 10–300V, accuracy: 0.5% |
| Test Current | AC/DC 0.1A–20A, accuracy: 0.5% |
| Test Items | Voltage, current, power, vacuum level, air volume, suction power, efficiency |
| Vacuum Gauge | Range: -50–0 kPa, accuracy: ±0.075%/±0.05% |
| Equipment Power Supply | 220V 50Hz, 1.5KW |
| Equipment Dimensions | 1850×680×1680 mm |
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| High Velocity Impact Testing Machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com Main Purpose To test the impact - resistance performance of glasses, goggles and face shie... | |
| ASTM ISO Air Jet Erosion Tester Supplier China | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Air Jet Erosion Tester is a controlled gas-driven erosion testing system ... | |
| High-Precision Multi-Functional Thermal Property Testing System | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The platform supports internationally recognized absolute measurement standards,... | |
| Vibration and Crash Simulation Dummy for EV Batteries | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The dummy complies with and supports testing according to the following standard... | |
| Sweating Guarded Hotplate Manufacturer | ISO 11092 Thermal Resistance Testing Equipment | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ISO 11092: International standard for "Textiles — Physiologi... |