Cabin Air Filter Test System(Gas Adsorption) | ASTM ISO Testing Machine
Get a quote:
Whats/App: +86 185 0176 3615
Web: qinsun-lab.com
Test System for both particle separation and gas absorption/desorption of of air filters for passenger compartments (DIN 71460-1/2, ISO 11155-1/2). It povides a maximum of paramater testing for cabin air filters.
Applications
Fractional efficiency according to ISO 11155-1 (DIN 71460-1)
Gas adsorption tests according to ISO 11155-2 (DIN 71460-2)
Adsorption/desorption tests
Research and development tasks on automotive cabin air filters
Standards
GB/T 32085.1 — Automotive Air Conditioning Filters, Part 1: Dust Filtration Test
GB/T 32085.2 — Automotive Air Conditioning Filters, Part 2: Gas Filtration Test
DIN 71460-1 — Road Vehicles, Cabin Air Filters, Part 1: Particulate Filter Test
DIN 71460-2 — Road Vehicles, Cabin Air Filters, Part 2: Gas Filter Test
ISO/TS 11155-1 — Road Vehicles, In-Cabin Air Filters, Part 1: Dust Filtration Test
ISO 11155-2 — Road Vehicles, In-Cabin Air Filters, Part 2
ISO 10121-1 / ISO 10121-2 — General Methods for Air Filter Performance Testing
Features
standard compliant testing of filter media and filter elements
combined testing with particles and with gases
very flexible system configuration possible
Technical Data
| Parameter | Unit | Value |
|---|---|---|
| Test flow rate | m³/h | 70 … 700 |
| Test aerosol | – | DEHS, DOP, PAO, KCl, NaCl, etc. |
| Test gases | – | n-Butane 80 ppm, Toluene 80 ppm, Sulfur dioxide 30 ppm, Hydrogen sulfide 10 ppm |
| Measuring range, differential pressure | Pa | 0 … 1000 (± 2 %) |
| Test specimen dimensions | mm | max. 600 × 300 |
| Operating medium (gas/air) | – | Room air at standard test conditions (23°C ± 2 K; 50 % ± 2 % RH) |
| Power supply | – | 400 VAC / 3P / 75 A / 50 … 60 Hz and 3 × 230 VAC / 2P / 16 A / 60 Hz |
| Aerosol generation technology | – | Dust disperser SAG 410/L, Atomizer ATM 220, etc. |
| Aerosol conditioning technology | – | Electrostatic Aerosol Neutralizer EAN 581 |
| Aerosol measurement instruments | – | Aerosol spectrometer LAP 322 |
| Gas analysers | – | FID, NDIR |
| Sensors (others) | – | Temperature, relative humidity, absolute pressure |
| System dimensions (W × H × D) | mm | 3700 × 3000 × 3700 |
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Testing dummy body parts-Back, Body & Butt Forms | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The 5th Percentile Female SAE Butt Form is meticulously derived from the NHTSA Hyb... | |
| Static Tensile Tester | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Standard ASTM D3107Ensurereliable measurement of fabric elongation and tensile pr... | |
| Micron Tester | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Email: serving@qinsun-lab。com Compliant Standards - GB 1103-2007: China's nation... | |
| Photovoltaic Ammonia Test Chamber | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Applications The Photovoltaic Ammonia Test Chamber is a testing device designed t... | |
| Thermal Protective Performance Tester (TPP) | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The Thermal Protective Performance Tester (TPP) is designed to evaluate the therma... |