Walk-in High-Temperature Aging Chamber IEC 60068-2-2 Manufacturer
Get a quote:
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Standards
GJB150.3 (ML-STD-810D) High Temperature Test Method
GJB150.4 (MIL-STD-810D) Low Temperature Test Method
GJB360.8-87 (MIL-STD-202f) High Temperature Life Test
GB/T5170.2-96 Temperature Test Equipment
GB2423.1-89 (IEC68-2-1) Basic Environmental Test Procedures for Electrical and Electronic Products Test A: Low Temperature Test Method
GB2423.2-89 (IEC68-2-2) Basic Environmental Test Procedures for Electrical and Electronic Products - Test B: High Temperature Test Method
GB5170. 2. 3. 5. 6-95 “Calibration Methods for Basic Parameters of Environmental Test Equipment for Electrical and Electronic Products - Low Temperature, High Temperature, Constant Humidity and Heat, Alternating Humidity and Heat Test Equipment” Requirements
Features
1. Simple maintenance and user-friendly operation are key advantages of our products.
2. The independent frame design ensures the refrigeration system and air distribution system operate separately.
3. Maintenance and repairs can be performed during unit operation, resulting in low annual failure rates and simplified, rapid servicing.
Parameters
| Item | Specifications |
|---|---|
| Dimensions | 200 cm (W) × 200 cm (H) × 200 cm (D); customizable per customer requirements, with external dimensions subject to actual size |
| Temperature Range | Optional ranges: 0°C~20°C / -40°C~60°C / -70°C~+85°C / 100°C (lower temperature ranges are higher in cost; choose based on product needs) |
| Temperature Fluctuation | ±0.5°C (defined as half the difference between the highest and lowest measured temperatures at the center point) |
| Temperature Uniformity | ±2.0°C (defined as the arithmetic mean of the differences between highest and lowest measured temperatures per test) |
| Heating Time | From room temperature (+10°C) to +85°C: <60 minutes, non-linear no-load heating rate ≈3°C/min |
| Cooling Time | - From +10°C to 0°C: <30 minutes, non-linear no-load cooling rate ≈1°C/min- From +10°C to -20°C: <45 minutes, non-linear no-load cooling rate ≈1°C/min- From +10°C to -40°C: <60 minutes, non-linear no-load cooling rate ≈1°C/min |
| Operating Noise | A-weighted sound level ≤60 dB(A), measured in anechoic chamber at 25°C ambient temperature, using A-weighting, averaged over 8 test points (each at 1m from noise source and 1m above ground) |
Accessories
Temperature and humidity sensors
LED display control panel with PID auto-tuning
Stainless steel air circulation ducts and heating elements
Safety devices: fuses, overload protection, leakage detection
Adjustable shelving for test samples
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| LSFT Large-Scale Fire Test System Manufacturer | Fire Dynamics & Heat Release Test Equipment | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com E-mail:info@standard-groups。com Parameters ItemSpecification Foo... | |
| Blow-By Test Rig,ISO 8178 internal combustion engine blow-by test system | Whats/App: +86 156 1874 6768 Web: standard-groups.com Test system for the characterisation of the oil content in blow-by gases at engine test sys... | |
| Dry Type Thermal Manikin for Thermal Comfort Research | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system is designed and manufactured with reference to the following internat... | |
| Guarded Heat Flow Measurement System | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ASTM E1530: Standard Test Method for Evaluating Thermal Resistance of Materials ... | |
| Bundesmann Rain Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Bundesmann Rain Tester simulates natural rainfall to evaluate the water repellency, wet... |