SATRA TM55 Leather Low-Temperature Flexing Tester Manufacturer | Factory Direct Sale
Get a quote:
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Features
1. Inner and Outer Tank Material: Stainless Steel #304
2. Controller: PLC Control System with Touchscreen Display
3. Protective Devices: Thermal Protection Shutdown, Ground Fault Protection Shutdown, Over-Temperature Protection, Overload Protection, and other functions
Parameters
| Item | Specifications |
|---|---|
| Temperature Range | Room temperature ~ -30°C |
| Inner Chamber with Low-Temperature Flexing Fixture | - Fixture quantity: 12 sets- Sample size: 70mm×45mm- Flexing angle: (22.5±0.5)°- Flexing rate: (100±5) cycles/min- Flexing count range: 0 ~ 999.999 cycles- Distance between upper edge of lower fixture and upper fixture: (25.0±0.5) mm |
| Control Accuracy | ±0.5°C, V4.0 |
| Temperature Uniformity | ±2°C |
| Cooling Rate | Approximately 45 minutes from room temperature to -30°C |
| Refrigerant | R404 (environmentally friendly refrigerant) |
| Compressor Start Delay | 5 minutes |
| Power Consumption | 4KW |
| Insulation Material | Rigid foam and glass wool |
| Counter | Touchscreen display, adjustable from 0 ~ 999.999 |
| Viewing Window | (210×35×270) mm, two-layer vacuum glass |
| Viewing Window Light | P1 lamp, 5W |
| Power Supply | AC220V 50Hz |
| Motor | Beltless, multi-imported gear reduction motor |
| Inner Chamber Dimensions | (60×60×55) cm |
| Overall Dimensions | (110×105×160) cm |
| Weight | Approximately 420 kg |
Accessories
Main Unit: 1 unit
Flexing Fixture: 1 set
Chinese Instrument Manual: 1 copy
Instrument Warranty Card: 1 copy
Upper Material Low-Temperature Flexing Test Piece: 70×65mm
Product Certificate of Conformity: 1 sheet
Laser Engraving Die Cutter: 1 piece
Product Operation Manual: 1 copy
Delivery Note: 1 sheet
Acceptance Note: 1 sheet
Test Procedures
1. Equipment Preparation
Installation and Calibration: Position the testing machine on a level, stable workbench to ensure no wobbling. Connect the power supply and verify electrical connection. Install the bending die, adjust the fixture position to align with the power output center, and set appropriate clamping force based on specimen thickness.
Environmental Check: Confirm the laboratory environment meets standard test conditions (e.g., temperature, humidity) to prevent external factors from interfering with test results.
2. Specimen Preparation
Cutting and Inspection: Cut specimens according to standards (e.g., ASTM D1790 or QB/T 2714), typically sized 70mm × 45mm or 70mm × 25mm. Inspect edges for neatness, ensuring no notches or cracks, and verify the weathering surface shows no significant defects.
Folding and Securing: Fold the sample 180° with the weathered surface facing outward, aligning edges flush. Secure with clamps or tape to prevent misalignment.
3. Parameter Settings
Temperature Setting: Configure the low-temperature chamber based on material properties (e.g., standard leather or cold-resistant specialty materials). Range typically spans -30°C to -50°C with ±0.5°C temperature control accuracy.
Bending Parameters: Set the bending angle (e.g., 22.5° ± 0.5°) and speed (100 ± 5 cycles/minute) to comply with test standards (e.g., ASTM D813 or ISO 132).
4. Test Execution
Pre-cooling Treatment: Place the specimen and fixture into the low-temperature chamber. Maintain at the set temperature for 1-2 hours to ensure uniform specimen temperature.
Initiate Test: Within 1 second, press the upper plate of the flexing machine to the preset gap. Hold for 1 second before removing the specimen. Start the testing machine and monitor its operation to ensure temperature, speed, and angle align with settings.
Process Monitoring: Continuously check instrument displays. Immediately halt the machine and investigate if temperature anomalies or flexing deviations occur.
5. Result Evaluation
Recovery and Inspection: After the specimen returns to room temperature, examine the bending area with a magnifying glass. Document any cracks, delamination, or fractures. Results are graded as “No Cracks” or “Number of Bends at Crack Occurrence.”
Data Recording: Meticulously log test parameters and defect types for material performance assessment.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Wide-Load Friction and Wear Test Equipment | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system supports test methods commonly referenced in international tribology ... | |
| Automated single fiber flexibility equipment | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ASTM A370. ASTM A416. ISO6934.4 The Single Fiber Bending Tester makes it possib... | |
| Photovoltaic module damp heat test chamber | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard IEC 61215: Terrestrial Photovoltaic (PV) Modules – Design Qualification and... | |
| Metal Bone Screws Self - tapping Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard ISO 6475: Implants for surgery – Wear of total hip-joint prostheses ASTM F... | |
| Solar Climatic Test Chamber | Whats/App: +86 156 1874 6768 Web: standard-groups.com Features and Benefits 1. Fully Compliant with IEC 61215 Specifically designed for the UV pr... |