Rail Transit Car Wire Abrasion Testing Machine | Railway Cable Wear Resistance Tester Manufacturer
Get a quote:
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Features
(1) Abrasion Monitoring – The machine automatically stops when the needle wears through the insulation and conductor contact occurs.
(2) U-Shaped Scraping Motion – Prevents one side of the sample from being scratched through prematurely.
(3) Adjustable Load – Supports 0.8–1.1 kg applied to the scraper for varying test intensities.
(4) Touch Screen Control – Allows precise setting of frequency, cycles, and count.
(5) Temperature Safety Monitoring – Ensures testing only occurs within defined ambient temperature ranges.
(6) High-Precision Transmission – Imported double slide rail mechanism ensures smooth, accurate needle movement.
(7) Sample Protection – Plexiglass cover maintains stable ambient conditions and prevents external interference.
Parameters
| Parameter | Specification |
|---|---|
| Test Stroke | >10 mm |
| Scraping Needle Displacement | 20 mm ± 1 mm |
| Scraping Length | 15.5 ± 1 mm |
| Movement Frequency | 50–60 cycles/min (touch screen adjustable) |
| Counter | 6-digit, touch screen setting |
| Test Times | 6 times, touch screen setting |
| Minimum Distance to Sample Ends | >10 mm |
| Sample Rotation Angle | 90° |
| Sample Length | ~750 mm, firmly fixed on steel anvil |
| Applied Load on Scraper | 0.8 kg / 0.9 kg / 1.0 kg / 1.1 kg |
| Needle Diameter | 0.45 mm ± 0.01 mm (spring wire) |
| Scraper Motion | U-shaped movement to prevent unilateral wear |
| Test Temperature Monitoring | Prevents start or stops machine automatically if ambient temperature is out of range |
| Control System | Servo motor, touch screen + PLC (imitating Swiss imported model) |
| Transmission Mechanism | Imported double slide rail type |
| Safety & Sample Protection | Plexiglass cover prevents ambient temperature fluctuations affecting test |
Maintenance Information
(1) Keep the steel anvil, scraper, and needle clean and free of debris.
(2) Inspect the scraper and needle before each test for damage or wear.
(3) Ensure the slide rails are lubricated for smooth operation.
(4) Verify touch screen settings and calibration regularly.
(5) Maintain the plexiglass cover and control system to prevent ambient temperature fluctuations.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Nonwovens liquid loss tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Nonwovens Liquid Loss Tester is a precision instrument designed to evaluate the liquid ... | |
| American European bending tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Test Purpose: To determine if metal wires in children's products bend or break under stres... | |
| Multi-function drum and reciprocating tribology tester factory | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application This testing machine is suitable for friction and wear evaluation under both l... | |
| Shoe heel abrasion sample grinder manufacturer | Application This instrument is used for: (1)Footwear Testing Laboratories:Preparation of heel samples for abrasion testing. (2)Quality Control:E... | |
| Laboratory Catheter Friction Testing Bench for Sale | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Catheter Friction Tester is a precision instrument used to measure the su... |
Похожие товары
| MMA-120 Handheld Arc Welder | Продавец: 871183 | The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con... | |
| SHX Series Circulating Fluidized Bed Steam Boiler | Продавец: Hebei Genjux Boiler Co.,Ltd | Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi... | |
| YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler | Продавец: Hebei Genjux Boiler Co.,Ltd | Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ... | |
| DHL Series Coal-Fired Steam Boilers | Продавец: Hebei Genjux Boiler Co.,Ltd | Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b... | |
| SZL Series Biomass Steam Boiler | Продавец: Hebei Genjux Boiler Co.,Ltd | Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi... |