Building Material Flammability Test Furnace, ISO 11925-2 Flammability Tester

Get a quote:

Whats/App: +86 156 1874 6768

Web: standard-groups.com

E-mail:info@standard-groups。com

Parameters

Stainless steel plate box 1.5mm
Bunsen burner can be adjusted forward and backward
Diameter of burner Φ 0.17mm burner with regulator; four ¢4mm air suction inlet
Flame length of Bunsen burner 20mm ± 2mm
Ignition source can be automatically tilted by 45 degrees
The Bunsen burner applies a flame time 15s to the pattern
Flame height Adjusted by precision adjustment valve
Sample rack can move up and down and back and forth
Sample holders 2 pcs
Touch screen display 7 inches Effective display size 15.5cm in length and 8.6cm in width
Resolution 800 * 480
Communication interface RS232. 3.3V CMOS or TTL, serial port mode
Storage capacity 1G
FPGA driver display "zero" start time, can run after power on
Controller adopts low energy consumption processor, and automatically enters energy saving mode
Gas source >95% propane gas;(user should provide for themselves)
Gas pressure 10kpa~50kpa
Flue air velocity 0.7m/s only on condition of burner burning and draught hood open
Time adjustment of continuous flame 0 ~ 99minutes99seconds
Time adjustment of afterflame 0 ~ 99minutes99seconds
Timer accuracy ≤1s/h
Ambient temperature 15 ℃ ~ 25 ℃;
Relative humidity ≤ 85%
Cabinet size 835 × 400 × 815mm
Power supply voltage and power 220 V, 50 Hz, 100 W

Accessoriess

1. Building Material Flammability Tester 1 unit

2. Power cord 1 piece

3. Gas pipe (with clamp) 1 piece

4. Clamps 2 sets

5. Flame height measuring device 1 unit

6. Flame positioner 2 units

7. Stainless steel wind speed device (optional) 1 set

8. Product manual 1 copy

9. Product certificate of conformity 1 piece

Test Procedures

I. Equipment Installation and Preparation

Accessory Check: Confirm that the included accessories include the sample holder, positioning device, drip tray, flame ruler, gas valve, and gas pipe. If a wind speed device is selected, an additional power supply needs to be connected, and the wind speed should be adjusted to 0.7 ± 0.1 m/s.

Gas and Power Connection: Install the valve onto the gas cylinder (the safety valve needs to be opened manually), and connect the equipment's power and gas supply. If a wind speed meter is equipped, calibrate the airflow direction and insert it into the temperature measurement port.

II. Operating Procedure

Parameter Settings: Set the experiment time (usually 15 seconds or 30 seconds) via the touchscreen interface, and select whether to enable the "automatic ignition" or "automatic gas shut-off at the end of the experiment" function.

Sample Installation: Use the sample holder to fix the material (usually 250mm × 90mm), and adjust the flame contact position using the positioning device (e.g., 40mm from the bottom edge).

Flame Adjustment: Start the gas and ignite the flame, adjust the Bunsen burner to a 20 ± 2mm blue flame, and tilt it 45 degrees towards the sample.

III. Experiment Execution and Observation

Start Experiment: After clicking "Start," the burner contacts the sample and the countdown begins. Observe the combustion phenomena (e.g., surface ignition, burning to the marked line).

Data Recording: Save the data after the experiment, turn off the gas, and check the sample's combustion status (e.g., remaining length, whether dripping material ignites the filter paper).

IV. Safety and Maintenance

Operating Procedures: Avoid putting hands into the test furnace, and do not stack flammable materials around the equipment. Stop the machine immediately in case of any abnormalities.

Regular Calibration: Calibrate the heat load uniformity (4-point temperature difference ≤ 15℃) and wind speed (5-point measurement error ≤ 10%) every 3 months.


Отправить запрос, связаться с поставщиком

Кому: Standard International Group (HK) Limited
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

Floor Material Burning Performance Tester
Floor Material Burning Performance Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Thefloor coverings flammability testeris used to tester a variety of flooring materials, su...
Laboratory Filter Media Performance Testing Device Without Vertical Duct
Laboratory Filter Media Performance Testing Device Without Vertical Duct Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The G508 test bench supports parameterized test conditions in accordance with th...
Railway Locomotive Cable Dynamic Cut-through Tester
Railway Locomotive Cable Dynamic Cut-through Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The Railway Locomotive Cable Dynamic Cut-through Tester is designed to evaluate the insulat...
Protective Clothing Liquid Static Pressure Tester
Protective Clothing Liquid Static Pressure Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards GB24540-2009,LFY-252 Instrument use The acid-proof clothing material anti-seep...
OEM Camera Airtightness Testing Machine
OEM Camera Airtightness Testing Machine Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards (1) IEC 60529 (IP Code protection classification) (2) ISO 20653 (...
Все товары поставщика

Похожие товары

Common Rail Injector Valve F00R J01 334
Common Rail Injector Valve F00R J01 334 Продавец: 868983 Common Rail Injector Valve F00R J01 334 Injector Valve Set F00V C01 361 Injector Valve Set F00V...
Common Rail Injector Valve F 00V C01 371
Common Rail Injector Valve F 00V C01 371 Продавец: 868983 Common Rail Injector Valve F 00V C01 371 Injector Valve Set F00V C01 310 Injector Valve Set F00...
Common Rail Injector Valve F 00V C01 365
Common Rail Injector Valve F 00V C01 365 Продавец: 868983 Common Rail Injector Valve F 00V C01 365 Injector Valve Set F00V C01 303 Injector Valve Set F...
Common Rail Injector Valve F 00V C01 329
Common Rail Injector Valve F 00V C01 329 Продавец: 868983 Common Rail Injector Valve F 00V C01 329 Injector Valve Set F00V C01 054 Injector Valve Set F...
Common Rail Injector Valve F 00V C01 325
Common Rail Injector Valve F 00V C01 325 Продавец: 868983 Common Rail Injector Valve F 00V C01 325 Injector Valve Set F00V C01 044 Injector Valve Set F...