Parameters

Items Parameter
Apllication Load and quality control
Max Efficiency 99.999%
Aerosol Type DOP/PAO/DEHS/Paraffi/Others Oil Aerosol、Salt
Aerosol Generation Atomizing
CMD 0.2μm(Oil)or 0.75um(NaCl)
GSD <1.6(Oil)or <1.86(NaCl)
Flow Rate 15-100L/min
Resistance 0-150mm H2O(0-1470Pa)
Particle Detect Scatter Photometer
Measurement Time 10 Sec.
Data Report LCD,RS-232
Operation Independent tewster、automatic production line
Standard compliant US 42 CFR part 84.EN 143.JMOL,ISO 23328-1 ISO 16900-3
Power Supply 115VAC、60Hz,10A或230VAC,50Hz,5A
Compressor Air 80psig,7scfm(550kPa,198std.L/min)
Dimension 70cm x 70cm x 147cm(28in, x 28in.x 58in.)

Accessoriess

Main Unit: As the core component of the testing instrument, it is responsible for overall control and data processing.

Aerosol Generator: Includes salt particulate aerosol generators and oil particulate aerosol generators, used to generate the aerosol particles required for the test.

Classifier: Utilizes the principle of inertia to collect unwanted large particles into a collection bottle, ensuring that the aerosol particles entering the testing system meet the requirements.

Particle Counter: Usually equipped with two units, used to measure the number or mass concentration of aerosols upstream and downstream of the filter media, and is a key device for calculating filtration efficiency. Some systems may use a laser scattering photometer instead of a particle counter.

Static Neutralization Device: Neutralizes the static electricity carried by the aerosols, reducing particle loss and the influence of static electricity on the test results.

Differential Pressure Sensor: Monitors the pressure drop across the filter media, assessing changes in resistance during the filtration process.

Flow Meter: Monitors the flow rate during the test, ensuring consistency of test conditions. Flow meters are typically 2.5 grade accurate, ranging from 10-100 L/min.

Vacuum pump: Provides the necessary negative pressure environment to ensure aerosol particles can smoothly enter the testing system.

Pneumatic clamps and protective devices: Employ pneumatic clamping, offering convenient operation and high safety, while also featuring protective devices to ensure safe use.

Programmable logic controller (PLC) and touchscreen: Enables automated control of the testing process, including control, monitoring, calculation, and data display functions. Some devices utilize a PLC control system and are equipped with a 7-inch color touchscreen.

Instruction manual and power cord: Provides an operation guide and power connection instructions to ensure users can correctly operate the equipment.

Test Procedures

Operating Procedures:

First: Prepare the accessories and test sample;

Turn on the instrument and enter the LCD screen operating interface;

Perform a no-load test first;

Press the dual-control pneumatic keys on both sides to lower the clamp;

Set the airflow rate and aerosol particle parameters;

After the data stabilizes, proceed to the next step;

Obtain the amount of aerosol upstream of the filter media;

Once the data stabilizes, a "Place Clamp" dialog box will pop up on the screen;

Place the prepared sample into the instrument clamp and clamp it securely;

Start the test;

Wait a few seconds to obtain the amount of aerosol downstream of the filter media and calculate the filtration efficiency;

The instrument will automatically print out the test report;

Remove the sample;

After the test, turn off the instrument and evaluate the filtration performance of the material based on the test data results.


Отправить запрос, связаться с поставщиком

Кому: Standard International Group (HK) Limited
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

Bottle Wall and Bottom Thickness Tester
Bottle Wall and Bottom Thickness Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The wall and bottom thickness tester for bottles is a measuring instrument widely used in t...
EN sole bending tester
EN sole bending tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The EN Sole Bending Tester is designed to assess the bending resistance and zigzag durabili...
ISO 13937-1 Fabric Tear Strength Tester for Textile Laboratories
ISO 13937-1 Fabric Tear Strength Tester for Textile Laboratories Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Wide test range The tester is equipped with multiple ranges and is used for ...
Dry Microbial Penetration Resistance Tester
Dry Microbial Penetration Resistance Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The Dry Microbial Penetration Resistance Tester assesses material resistance to dry bacteri...
SDC Fading Grey Scale
SDC Fading Grey Scale Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ISO 105-A02(Grey Scale for Assessing Change in Color) AATCC Evaluation Proced...
Все товары поставщика

Похожие товары

MMA-120 Handheld Arc Welder
MMA-120 Handheld Arc Welder Продавец: 871183 The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con...
SHX Series Circulating Fluidized Bed Steam Boiler
SHX Series Circulating Fluidized Bed Steam Boiler Продавец: Hebei Genjux Boiler Co.,Ltd Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi...
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler Продавец: Hebei Genjux Boiler Co.,Ltd Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ...
DHL Series Coal-Fired Steam Boilers
DHL Series Coal-Fired Steam Boilers Продавец: Hebei Genjux Boiler Co.,Ltd Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b...
SZL Series Biomass Steam Boiler
SZL Series Biomass Steam Boiler Продавец: Hebei Genjux Boiler Co.,Ltd Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi...