Polypectomy Snares (Hot & Cold)
This device is indicated for use endoscopically for the removal of polyps.
Features of Endoscopy Snares(Hot & endoscopy cold snare)
Snares are available in Oval, Hexagon and Half-moon shapes.
Hot & cold hybrid function satisfy current doctors desire.
360° 1:1 rotation for precise adjustment.
Specification of Cold Snare Polypectomy& Hot Snare Polypectomy
Rgeular items
|
REF |
Catheter |
Snare |
Units/Box |
|||
|
Fixed |
Rotatable |
Catheter Diam. (mm) |
Working length (mm) |
Opening Width (mm) |
Configuration |
|
|
L16CA241806A1 |
L16RA241806A1 |
1800 |
6 |
Oval |
10 |
|
|
L16CA241808A1 |
L16RA241808A1 |
1800 |
8 |
|||
|
L16CA241810A1 |
L16RA241810A1 |
1800 |
10 |
|||
|
L16CA241815A1 |
L16RA241815A1 |
1800 |
15 |
|||
|
L16CA241825A1 |
L16RA241825A1 |
1800 |
25 |
|||
|
L16CA242406A1 |
L16RA242406A1 |
2400 |
6 |
|||
|
L16CA242408A1 |
L16RA242408A1 |
2400 |
8 |
|||
|
L16CA242410A1 |
L16RA242410A1 |
2400 |
10 |
|||
|
L16CA242415A1 |
L16RA242415A1 |
2400 |
15 |
|||
|
L16CA242425A1 |
L16RA242425A1 |
2400 |
25 |
|||
|
L16CB241810A1 |
L16RB241810A1 |
1800 |
10 |
Hexagon |
||
|
L16CB241815A1 |
L16RB241815A1 |
1800 |
15 |
|||
|
L16CB241822A1 |
L16RB241822A1 |
1800 |
22 |
|||
|
L16CB242410A1 |
L16RB242410A1 |
2400 |
10 |
|||
|
L16CB242415A1 |
L16RB242415A1 |
2400 |
15 |
|||
|
L16CB242422A1 |
L16RB242422A1 |
2400 |
22 |
|||
What is Cold SnarePolypectomy
Endoscopic resection of gastrointestinal polyps is the endoscopic removal of gastrointestinal polyps. There are usually biopsy forceps removal, including cold biopsy forceps and hot biopsy forceps. The excision of the snare includes the excision of the cold snare and the hot snare high frequency electrical snare. In addition, there is submucosal resection. For larger polyps, endoscopic submucosal dissection may be used. It is necessary to consider which method of endoscopic resection should be selected according to the size of the polyp, the location of the growth, and the blood flow.
Cold VS Hot SnarePolypectomy
Cold snare polypectomy is an easy-to-apply technique and remains the most popular technique, especially for small polyps. According to studies, the complete resection rate of cold snare is very close to or equal to that of hot snare for polyps of 6 to 9 mm. Cold snare can be considered an effective treatment for small polyps, with the advantage that in most cases, cold snare reduces the risk of delayed complications. Thermal snare may be appropriate for occasional 6-9 mm polyps that have thicker stems or have a very prominent sessile component. Cold snare can be very effective and safe when dealing with large numbers of polyps.
Cold Snare Polypectomy Technique
Advantages of cold snare polypectomy include
Leo Medical Co., Ltd. Is a professional endoscopy accessories manufacturer, we provide endoscope accessories, pulmonary products, hexagonal snareand etc. Want to know polypectomy snare priceor more ? Please contact us.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Progressive Dilatation Balloon | Leo Medical Co.,Ltd. is committed to providing affordable and qualified endoscope accessoriesin Gastroenterology, Respirology, as well as the medic... | |
| Single-use Nitinol Stone Retrieval Basket | Endoscopy retrieval basket is used for capturing and retrieving stones and foreign bodies via endoscope. Features of Single-use Nitinol Stone Bask... | |
| Single-Use Pulmonary Balloon Dilatation Catheter | Used for endoscopic dilate strictures of the airway tree. Features of Single-Use Pulmonary balloon dilation catheter lThree distinct diameters ... | |
| Single-use Stone Extraction Catheter | Biliary balloon extraction ercp catheter is used for endoscopic removal of biliary stones. Features of Single-use Stone Extraction Catheter Hi... | |
| Single-use Stone Extraction Catheter | Biliary stone extraction balloon catheter is used for endoscopic removal of biliary stones. LeoMed offers a competitive stone extraction balloon p... |
Похожие товары
| R404a Scroll Compressor for Cold Chain Transportation | Продавец: Scroll Air Compressor,Electric Scroll Compressor | Optimized for Cold Chain Vehicles & Containers The34cc R404a scroll compressor for cold chai... | |
| Electric scroll compressor with R404a Refrigerant | Продавец: Scroll Air Compressor,Electric Scroll Compressor | Introduction Leling's compact refrigeration scroll compressor (18CC) is specially engineered for... | |
| Vapor Injection Compressor With Enhanced Enthalpy | Продавец: Scroll Air Compressor,Electric Scroll Compressor | The vapor injection compressor with enhanced enthalpy is a new type of compressor improved on the... | |
| R404a Refrigeration Compressor | Продавец: Scroll Air Compressor,Electric Scroll Compressor | R404a Refrigeration Compressor The refrigeration and freezing scroll compressor is a type of com... | |
| DC variable frequency electric scroll compressor | Продавец: Scroll Air Compressor,Electric Scroll Compressor | The electric scroll compressoris mainly composed of moving scroll plate, stationary scroll plate,... |