Residual Ethylene Oxide Gas Chromatography System

The Residual Ethylene Oxide Gas Chromatography System is a professional analytical instrument designed for the detection and quantification of residual ethylene oxide (EO) and its related compounds (ethylene chlorohydrin, ECH; ethylene glycol, EG) in medical products. It provides high sensitivity, accuracy, and compliance with international and national standards, ensuring the safety of sterilized medical devices and related products.

Application

The system is suitable for the analysis of residual ethylene oxide in the following industries and products:

(1) Medical Device Industry: surgical instruments, catheters, syringes, implants, and other sterilized medical equipment — residual EO detection

(2) Pharmaceutical Industry: sterilized vials, ampoules, and packaging materials — EO residue quantification

(3) Hospital Sterilization Facilities: EO-sterilized medical consumables, hospital sterilization quality control — monitoring residual EO levels

(4) Quality Control Laboratories: medical product manufacturers, third-party testing labs — EO residue compliance testing

(5) Research and Development: development of new sterilization processes, optimization of EO sterilization protocols

(6) Regulatory Compliance Testing: submission of data for ISO, USP, Ph. Eur., JP, and national pharmacopoeial requirements

Standards

The instrument is compliant with and suitable for use with the following standards:

(1) ISO 10993-7:2021 – Biological evaluation of medical devices — Part 7: Ethylene oxide sterilization residuals

(2) United States Pharmacopeia (USP) – relevant chapters for chromatography and biocompatibility testing

(3) European Pharmacopoeia (Ph. Eur.) – e.g., 2.2.28 Gas Chromatography for sterilizing agent residues

(4) Japanese Pharmacopoeia (JP) – residual solvent and sterilizing agent testing methods

(5) National Standards – e.g., GB/T 16886.7 (China) for EO residual testing

Features

(1) High Accuracy and Sensitivity: Detects trace levels of EO, ECH, and EG in ppm or µg/g ranges

(2) Compliance Assurance: Meets ISO 10993-7, USP, Ph. Eur., and other pharmacopoeial requirements

(3) Reliable Detection: Hydrogen Flame Ionization Detector (FID) ensures robust and consistent results

(4) Automated Sample Preparation: Optional headspace samplers improve reproducibility and operator safety

(5) Comprehensive Data Analysis: Advanced software provides chromatograms, quantitative results, and reporting

(6) Ensures Product Safety: Monitors residual toxins to protect patients and healthcare workers

(7) Modular Design: Six independent temperature-controlled zones, modular chambers for easy installation and replacement

(8) Precise EPC Electronic Flow Control: 18 gas channels independently controlled for flow and pressure

(9) Power-Off Protection: Automatic parameter memory and immunity to sudden power fluctuations

(10) Extensive Self-Diagnosis: Real-time fault detection with suggested solutions

(11) Fully Integrated Control Workstation: Three digital and three analog outputs for comprehensive control

Technical Parameters

ItemSpecification
Gas Flow Control EPC electronic control, 18 independent channels
Injector Up to 3 independently temperature-controlled injectors
Temperature Control Zones 10 independent zones, including column, vaporization, FID, thermal conductivity, auxiliary 1 & 2
Detector Hydrogen Flame Ionization Detector (FID), high sensitivity
Power-Off Protection Automatic parameter memorization, power fluctuation immunity
Self-Diagnosis Real-time fault messages with solutions
Control Workstation Fully integrated, 3 digital + 3 analog outputs
Safety Automatic stop functions and modular design for easy replacement

Accessories

(1) Gas chromatograph column(s) suitable for EO/ECH/EG detection

(2) Headspace sampler (optional, automated)

(3) Injector liners and septa

(4) Hydrogen and air supply lines with regulators

(5) Data acquisition software with quantitative analysis module

(6) Calibration gas kits

(7) Operation manual

(8) Maintenance toolkit

(9) Power cable

Test Procedures

(1) Prepare sample according to the target product type and standard requirements

(2) Load sample into headspace vial or GC injector system

(3) Configure the GC method parameters including temperature zones, flow rates, and detector settings

(4) Start automated or manual analysis

(5) Acquire chromatograms and record quantitative residual EO, ECH, and EG values

(6) Verify results against pharmacopoeial limits (ISO 10993-7, USP, Ph. Eur.)

(7) Clean injector, column, and sampling system after testing

Maintenance Information

(1) Regularly clean injector, column, and detector chambers

(2) Replace septa, liners, and GC columns as recommended

(3) Verify calibration with standard gases before each batch of testing

(4) Maintain gas supply lines and regulators for consistent flow

(5) Keep software, logs, and calibration records updated for compliance documentation

(6) Store instrument in a clean, dry laboratory environment


Отправить запрос, связаться с поставщиком

Кому: Standard International Group (HK) Limited
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

Torsional Fatigue Tester
Torsional Fatigue Tester Standard YY/T 0857-2011 (China): Specifies torsional fatigue testing protocols for spinal pedicle screw-rod systems, including load ratios, freque...
Torsional Fatigue Tester
Torsional Fatigue Tester Standard YY/T 0857-2011 (China): Specifies torsional fatigue testing protocols for spinal pedicle screw-rod systems, including load ratios, freque...
Photovoltaic module outdoor exposure test system
Photovoltaic module outdoor exposure test system Standard IEC 61215: Terrestrial Photovoltaic (PV) Modules – Design Qualification and Type Approval IEC 61730: Photovoltaic (PV) Module Sa...
Yellowing resistance meter
Yellowing resistance meter Applicable standards HG/T3986. ASTM D1748. etc. Scope of application Test method for determining the yellowing resistance of light and white produc...
Flooring VOC Emission Test Chamber
Flooring VOC Emission Test Chamber Standard ISO 16000-9(Indoor Air - Determination of Volatile Organic Compounds) ASTM D5116(Standard Guide for Small-Scale Environmental Chamber ...
Все товары поставщика

Похожие товары

Gas Oxidizing Property Tester
Gas Oxidizing Property Tester Продавец: Standard International Group (HK) Limited Product Description Conforms to ISO 10156-2010 “Gases and Gas Mixtures Selection of Cylind...
Battery Powder Compaction Density Measurement System
Battery Powder Compaction Density Measurement System Продавец: Standard International Group (HK) Limited The Battery Powder Compaction Density Measurement System is a precision testing system designed...
Battery Powder resistance tester
Battery Powder resistance tester Продавец: Standard International Group (HK) Limited The Powder Resistivity Meter is a precision testing system designed to measure electrical resisti...
KES-SESRU surface roughness/friction tester
KES-SESRU surface roughness/friction tester Продавец: Standard International Group (HK) Limited TheRoughness/Friction Tester analyzes hand movements-particularly, strokes-performed by artisans ...
Air Permeability Tester STD- F8
Air Permeability Tester STD- F8 Продавец: Standard International Group (HK) Limited The Air Permeability Tester is designed to quickly and accurately measure the breathability and p...