Vacuum Blood Collection Tube Suction Volume Tester

In the medical field, particularly in processes involving blood sample collection, the accuracy of the suction volume of Vacuum Blood Collection Tube Suction Volume Testers is crucial. Specifically designed for testing the suction volume of single-use human venous blood sample collection containers, this device accurately measures the suction volume of vacuum blood collection tubes at different altitudes, ensuring compliance with relevant standards and providing a reliable foundation for clinical diagnosis and medical research.

Applications

The Vacuum Blood Collection Tube Aspiration Volume Tester is mainly used to detect the aspiration volume of disposable human venous blood sampling containers, especially to check whether they meet the standard requirements in different altitude areas. The tester precisely measures the aspiration volume of blood collection tubes by simulating different altitude or air pressure conditions, thereby evaluating the performance of blood collection tubes in various environments. This is crucial for ensuring the accuracy and reliability of blood collection tubes in actual use, and helps maintain the quality of blood samples and the accuracy of diagnostic results.

Standards

The design and manufacture of the Vacuum Blood Collection Tube Aspiration Volume Tester must comply with relevant medical industry standards, such as YY 0314 - 2021Disposable Human Venous Blood Sampling Containers. This standard clearly specifies key indicators, including the error range of the aspiration volume of blood collection tubes, container leakage tests, and container strength tests, to ensure the usability and safety of blood collection tubes. The tester must strictly adhere to these standards during the design and manufacturing process to ensure the accuracy and reliability of test results.

Features

1.Adoption of PLC Industrial Control System: The PLC industrial control system offers high stability and reliability, ensuring precise control of the testing process. It can quickly respond to various commands, enabling accurate adjustment of parameters such as test pressure and time, guaranteeing high accuracy and repeatability of test results. For example, when performing multiple blood collection tube aspiration volume tests, the PLC control system ensures consistent test conditions each time, improving testing efficiency and accuracy.

2. 7-inch HMI Touchscreen:Operation is simpler and more intuitive. Test personnel can easily set test parameters and view test results via the touchscreen, eliminating complex operating procedures. Even first-time users can quickly master the operation method, improving work efficiency.

3. Extra-thick Acrylic Vacuum Chamber: Provides excellent sealing and visibility. The sealing ensures the stability of the pressure environment during testing, preventing external air interference with test results; the visibility allows test personnel to observe the puncture and blood collection process of the blood collection tube, enabling timely detection and resolution of problems.

4. Built-in Vacuum Device:Eliminates the need for an external air source, reducing the complexity and cost of equipment use. Users only need to connect the power supply to quickly start testing, making it convenient and suitable for testing needs in various locations.

Technical Parameters

Serial No.Parameter ItemParameter Details
1 Vacuum Degree Test range: 0 - 90kPa (meets testing requirements of different altitude areas)
2 Vacuum Degree Accuracy 0.5- level (ensures measurement precision)
3 Vacuum Degree Maintenance Performance Equipped with automatic air-supplement and constant-pressure maintenance functions (ensures vacuum degree stability during testing)
4 Operation Control Mode Fully automatic control + touch-screen operation (simplifies testing process and improves efficiency)
5 Air Source Pressure Requirement 0.7 - 0.9MPa (air source to be provided by user; ensures normal operation of the tester)
6 Air Source Generator Uses imported components (e.g., Japanese SMC generators) with a stability of ±0.1kPa (improves testing accuracy)
7 Power Supply Supports multiple specifications (e.g., AC 220V 50Hz/120V 60Hz) (adapts to different regional power environments)
8 External Dimensions Main unit size: 300mm(L)×385mm(W)×150mm(H) (specific size may vary by model; easy to place and operate)
9 Weight Net weight of main unit: approximately 7kg (actual weight may vary by configuration; facilitates portability and movement)
10 Language Supports Chinese/English (standard configuration); other languages (e.g., Russian, Traditional Chinese) available for customization (meets different users' needs)

Accessoriess

1. Main Unit: The RDVT-01 testing instrument main unit integrates the PLC control system, human-machine interface touchscreen, vacuum chamber, and other core components, making it the core of the entire testing system.

2. Puncture Needle: Made of high-quality materials to ensure smooth and accurate puncture, avoiding damage to the blood collection tube.

3. High-Precision Weighing Sensor: Used to accurately measure the weight difference of the blood collection tube before and after testing, ensuring the accuracy of the test results.

4. Connecting Tubing: Features good sealing and corrosion resistance, ensuring stable and reliable pressure transmission.

5. Operation Manual: Provides detailed instructions on the operation methods and maintenance precautions of the testing instrument, helping users to correctly use and maintain the equipment.

Test Procedures

1. Sample Preparation

Randomly select 30 blood collection tubes and equilibrate them for 1 hour at 20℃±2℃.

Use standard Grade 3 water as the medium to avoid temperature fluctuations affecting density.

2. Equipment Calibration

Connect the pre-vacuum blood collection tube aspiration volume tester and vacuum pump, and remove air bubbles from the tubing.

Calibrate the vacuum level to the target value (e.g., -30 kPa for simulating an altitude of 3000 meters).

3. Test Execution

Insert the blood collection tube into the puncture site of the testing system, start the vacuum pump, and maintain stable pressure for 1 minute.

Record the weight difference of the blood collection tube before and after water aspiration, and calculate the individual and batch average aspiration volume.

4. Result Judgment

If the batch average aspiration volume is within ±10% of the nominal value, it is judged as qualified.

Generate a test report, including the pressure-time curve, weight data, and deviation analysis.


Отправить запрос, связаться с поставщиком

Кому: Standard International Group (HK) Limited
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

Femoral Condyles Components Fatigue Performance Tester
Femoral Condyles Components Fatigue Performance Tester Standard ASTM WK51649: Specifies fatigue testing protocols for metallic femoral components in total knee arthroplasty, including F-N curve generat...
Small Parts Tester
Small Parts Tester Test Procedure: Usage Methods and Interpretations Applicable standards: ASTM F963 EN 71-1 16 CFR Part 1501 ISO 8124-1 Product Advantages: Eff...
Intramedullary Nails/Bone Screw Static Torque Testing Machine
Intramedullary Nails/Bone Screw Static Torque Testing Machine Standard YY/T 0591-2011: Chinese standard specifying torsion testing methods for intramedullary nails, including torque application, angular displ...
Minimum Ignition Temperature (MIT) – Dust Cloud Tester
Minimum Ignition Temperature (MIT) – Dust Cloud Tester Dust Cloud Minimum Ignition Temperature Tester is mainly used to assess the explosiveness of dust in the production and processing places such as a...
Scratch tester STD-KK01
Scratch tester STD-KK01 Product introduction: With the continuous expansion of the use of plastic molding products, from the point of view of the surface appearance of mo...
Все товары поставщика

Похожие товары

Gas Oxidizing Property Tester
Gas Oxidizing Property Tester Продавец: Standard International Group (HK) Limited Product Description Conforms to ISO 10156-2010 “Gases and Gas Mixtures Selection of Cylind...
Battery Powder Compaction Density Measurement System
Battery Powder Compaction Density Measurement System Продавец: Standard International Group (HK) Limited The Battery Powder Compaction Density Measurement System is a precision testing system designed...
Battery Powder resistance tester
Battery Powder resistance tester Продавец: Standard International Group (HK) Limited The Powder Resistivity Meter is a precision testing system designed to measure electrical resisti...
KES-SESRU surface roughness/friction tester
KES-SESRU surface roughness/friction tester Продавец: Standard International Group (HK) Limited TheRoughness/Friction Tester analyzes hand movements-particularly, strokes-performed by artisans ...
Air Permeability Tester STD- F8
Air Permeability Tester STD- F8 Продавец: Standard International Group (HK) Limited The Air Permeability Tester is designed to quickly and accurately measure the breathability and p...