.

Infusion Apparatus Leakage Positive Pressure Tester

The M102 Infusion Apparatus Leakage Positive Pressure Tester is designed to evaluate the airtightness and sealing performance of medical injection syringes and infusion apparatus. It provides precise measurement of positive pressure integrity, ensuring that medical devices meet required safety standards. This instrument is widely used in laboratories, production quality control, and third-party certification testing.

Application

M102 Infusion apparatus leakage positive pressure tester, Itis suitable for the measurement of positive pressure airtight of medical infusion apparatus, blood transfusion devices, infusion needles, anesthesia bag filters, pipelines, conduits, quick joints, and etc. It can accurately measure whether the sealing performance of injection syringe meets the specified requirements.

It is applicable to the performance verification of new products, quality control of the production department, and the of material properties for the third-party testing organization, the product performance verification laboratory, and the quality and technical supervisiondepartment, etc.

The M102 tester is suitable for testing the positive pressure airtightness of medical devices in the following industries and products:

(1) Medical Devices: injection syringes, infusion sets, anesthesia bag filters — verification of sealing integrity under positive pressure

(2) Blood Transfusion Equipment: transfusion devices, infusion needles — assessment of airtightness to prevent leakage

(3) Pipelines and Conduits: medical tubing, quick joints, and connectors — evaluation of fluid-tight connections

(4) Research and Development: new infusion device prototypes, design optimization for airtight performance

(5) Quality Control Laboratories: production inspection of medical infusion devices to ensure compliance with standards

(6) Certification and Regulatory Testing: third-party laboratories performing performance verification for national and international medical device standards

Standards

The instrument complies with the following standards, including relevant international regulations:

(1) GB 8368-2005 – Disposable Infusion Sets for Single Use — Gravity Infusion Type, including airtightness requirements

(2) ISO 8536-4:2010 – Infusion equipment for medical use — Part 4: Infusion sets for single use, including leak testing methods

(3) ISO 13485:2016 – Medical devices — Quality management systems — Requirements for regulatory purposes (applies to testing and QC of infusion devices)

(4) ASTM F2392-04 – Standard Guide for Leak Testing of Medical Fluid Delivery Devices

Features

(1) Touch-tone control panel with LED digital display for easy operation

(2) Adjustable test pressure range: 0–100 kPa, with ≤ ±2.5% reading error

(3) Flexible test time setting (1–16 s) to meet various requirements

(4) Compact and portable design, suitable for laboratory or production line installation

(5) Automatic operation mode reduces manual intervention

(6) Accurate measurement ensures compliance with medical device safety standards

Technical Parameters

ItemSpecification
Control Mode Automatic
Test Pressure Range 0–100 kPa
Pressure Accuracy ±0.5 kPa
Test Time 1–16 s (adjustable)
Weight 30 kg
Power Supply AC 220 V, 50 Hz
Appearance Size 40 cm × 45 cm × 45 cm

Accessories

(1) Standard air source connector

(2) Sample fixture for injection syringes and infusion devices

(3) Power cable

(4) Operation manual

(5) Calibration certificate

Operating instructions

1. Turn on the power and turn on the power.

2. Click "next" and enter "main menu". There are four options of "setting", "test", "measurement" and "air release".

3. Click "setting", set the "stress" can be performed at this time, set the "time", "" date and time setting, just enter thecorresponding project selection and vessels of the specifications of the corresponding parameters can be confirmed to betested.

4. Click "set pressure" and click the corresponding number of test pressure to "confirm". (unit: Kpa. "Confirm" and return toset parameters.

5. Click "set time", and then click the corresponding number for the test to "confirm". Unit: seconds. "Confirm" and returnto set parameters.

6. Click "date & time". After clicking "date", enter the date of the test day to be confirmed. (the format is:year/month/day, change of time is similar to change of date. (" confirm "and return to the main menu.)

7. After clicking "measurement", first connect the standard air source, and then measure whether the internal data isstandard. This step is not required for normal operation. This option is used for metering authentication.

8. Click "release", i.e. the internal test data pressure value is clear.

9. See the "main menu" shown in the content and the vessels being measured parameters are set by matching, can click on the"test", after the test according to test results, a visual check to see if the set with the test values of qualified, clickon the "qualified" or "unqualified" after the "print". "Return" returns to the main menu.

Maintenance Information

(1) Keep the instrument clean and dry after each test

(2) Inspect connectors, sample holders, and air supply lines for wear or leaks

(3) Calibrate pressure sensors regularly to maintain accuracy

(4) Avoid excessive force or impact on the instrument to prevent damage

(5) Store in a safe, ventilated environment

(6) Maintain operation and calibration logs for regulatory compliance


Отправить запрос, связаться с поставщиком

Кому: Standard International Group (HK) Limited
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

Battery short-circuit tester丨Battery short-circuit chamber
Battery short-circuit tester丨Battery short-circuit chamber Product introduction The device is designed based on a variety of battery short-circuit test standards. According to the standard requirements, t...
Single - Strand Bending Test device
Single - Strand Bending Test device Standards ASTM A370. ASTM A416. ISO6934.4 The Single Fiber Bending Tester makes it possible to easily measure and quantify softness, elasticity, ...
Cleanliness automatic extractor
Cleanliness automatic extractor Component Cleanliness Cabinet equipped with cleaning modes such as pressure jet cleaning, perfusion cleaning, spray cleaning, etc., the cleaning ag...
Rapid Closed Cup Flash Point Tester
Rapid Closed Cup Flash Point Tester Reference Standards: SN/T 3077.1、SN/T 3077.2. SH/T 0768. DL/T 1354. ASTM D93、ASTM D6450、ASTM D3828、ASTM D7094、ASTM D7236、ASTM D56、ASTM D56、ASTM...
Ink printing proof press meter
Ink printing proof press meter How it works: Ink printing proof machine is mainly based on the principle of printing reproduction, through the simulation of the press pressure, ...
Все товары поставщика

Похожие товары

Gas Oxidizing Property Tester
Gas Oxidizing Property Tester Продавец: Standard International Group (HK) Limited Product Description Conforms to ISO 10156-2010 “Gases and Gas Mixtures Selection of Cylind...
Battery Powder Compaction Density Measurement System
Battery Powder Compaction Density Measurement System Продавец: Standard International Group (HK) Limited The Battery Powder Compaction Density Measurement System is a precision testing system designed...
Battery Powder resistance tester
Battery Powder resistance tester Продавец: Standard International Group (HK) Limited The Powder Resistivity Meter is a precision testing system designed to measure electrical resisti...
KES-SESRU surface roughness/friction tester
KES-SESRU surface roughness/friction tester Продавец: Standard International Group (HK) Limited TheRoughness/Friction Tester analyzes hand movements-particularly, strokes-performed by artisans ...
Air Permeability Tester STD- F8
Air Permeability Tester STD- F8 Продавец: Standard International Group (HK) Limited The Air Permeability Tester is designed to quickly and accurately measure the breathability and p...