Cone Calorimeter Heat Release Test Machine,ISO 5660,Benchtop Cone Calorimeter

Products

Heat release quantity is the core parametersto evalatethe fire behavior of materials and products.TESTech'sCone Calorimeter canmeet all existing standards (including ISO 5660. ASTM E 1354. ASTM E 1474. ASTM E 1740. ASTM F 1550. ASTM D 6113.NFPA 264.CAN ULC 135 and BS 476 Part 15).This equipment includes these systems such as heat release, mass loss, smoke generation,etc,and allow users to buy the parts they need one by one and add into the same chamber.This flexible feature is one of it'sadvantages.

Cone Calorimeter test theory is based onthe principle that the burn calories is proportional to the amount of oxygen's consumption,1KGoxygen consumption will produce 13.1 MJ heat.Test gas heat emission, ignition timing, oxygen consumption rate, CO/CO2generation rate, the gas flow will be measured all. Cone Calorimeter DAQ system can help users to easily control the entire test. 19 "touch screen can help realizing the automatictesting and reducing installation space. In addition, users can alsochangethe sample temperature, or adjust the temperature rise time to test,after settingup the virtual temperature at real fire conditions. This method can obtain thesimilar test resultsto real fire environment.

Standards

• ISO 5660: Reaction to fire tests - the rate of heat release, smoke generation rate and mass loss rate.

• ASTM E 1354: Standard Test Method of materials heat and visible smoke release rate.

• BS 476 Pt.15: Building materials and structures test: - Test method for heat release rate of products.

• NFPA 264

Structural features

19-inch standard cabinetof integrated design, elegant, and easy to operate.

Conical Heater of 230V, 5000W, the heat output of 0 ~ 120 kW / m2.

19-inch touch-screen computer controlling the entire testing process.

Automatic ignition system,and automatic burning time calculation.

3 pieces K-thermocouples and 3 PID temperature controllers for temperature regulation.

Split gate -To protect samples area before the test, and insure the initial measurement stability.The operator could have extra time to detect before the test start. If there is no opening closing mechanism, the flammable samples are easy to burn too early. So this extra time is very important for the operator.

The sample holder -The sample size is 100mm x 100mm, and thickness is not exceed 50mm;The central portion of the sample about 50mm*50mm is exposed to the heating cone center and deviation is ±1%.

Weighting system -quality is measured by the strain gauge load cell test, accuracy up to 0.1g. Equipped with swift electronic weighing parts,mechanical stop fixture can avoid moving damage, to ensure the equipment longevity.Weighing range is 0 ~ 3kg.

Measurement

Paramagnetic oxygen analyzer, the range is 0-25%; linear response

With a laser system to measure the smoke density, using a photodiode, 0.5 mW helium-neon laser, primary and backup photodetectors. Also equipped with the positioning bracket and 0.3.0.8 neutral density filter used for calibration.

High-precision load sensor measures the weight changes of the test material during test process.The test range is 0~3000g, and resolution ratio is 0.01g. The required test sample weight is less than 500g.

Temperature control system: PID temperature control, 3 dia1mm thermocouples to measure temperature of the radiation cone, In addition with a 1 mm armoured thermocouple measuring the temperature 100mm above the orifice plate.

Exhaust flow: This data is caculated by the differential pressure of the sharp edge holes on both sides of the exhaust pipe,which inner dia is 57mm±1mm,and cooperate with micro differential pressure transmitter.Located at 350mm above fan transducer,the pressure transmitter is connected to the control system,so as to automatic control of wind speed.

Calibration

The United States imported Metherm thermopile type heat flow meter is used to set on the surface radiation level.Equipped with water cooling systemtoprotecting the security ofheat flow meter. - Design range is 0~100k W / m², the accuracy of heat flow meter is ±3%, repeatability is ±0.5%.

The burner correction system use purity of 99.5% methane to calibrate the instrument heat release rate; methane mass flow meter precise control of the flow of methane.

Equipped with a water cooling system for heat flow meter.

Equipped with a square calibration burner.

Operating

Labview control system, which easy to operate, and precise to control.It could show the apparatus status; Calibrate the device and store the results; Collect the test data; Calculate the necessary parameters; display results according to the requirements of standard; take the average value by multiple tests.

PC via RS485 interface communication module and PLC communication link for data transmission and motion control;

PID temperature control module and power adjustment module links, thermostatically regulated by a programmable controller;

Signal acquisition and processing module connected with the air volume control module circuit, output by a programmable logic controller,Intelligent adjust the preset speed.Mechanical rotating module links PLC I/O port, to control the closure of rotary.

The system provides query capabilities. The system automatically test sample number and temperature profile data stored in the database system;

Technical parameters

Conical heater rated power is 5000W, heat output is 0 ~ 100 kW / m2.

The sample weighing range is 0 ~ 3000g; precision is 0.1g.

Paramagn etic oxygen analyzer, the concentration range is 0~25%, an oxygen analyzer is linear response, Britain Servomex oxygen sensor; 10% to 90% response time of less than 12s; output noise does not exceed 50ppm;. Reproduce the measured values lower than 100ppm,

Infrared CO2 analyzer range: 0 to 10%; accuracy of ± 0.01%;

Exhaust fan flow 0 ~ 50g / s adjustable, precision 0.1g / s

The compressor works: cold trap: 0 to 5 degrees;

Import diaphragm pump, flow rate: 33 l / min

Thermopile type heat flow meter designed range 0 ^ 100k W / m², heat flow meter accuracy is ± 3%; repeatability is ± 0.5%

The standard detector color accuracy ± 5%, output linearity (transmission) <1%, absolute permeability <1%;


Отправить запрос, связаться с поставщиком

Кому: Standard International Group (HK) Limited
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

Xenon Test Chamber/weather ometer
Xenon Test Chamber/weather ometer Introduction Weather-Ometer and Fade-Ometer tester adopts water-cooled xenon lamp. This instrument using argon arc lamp simulation control ideal n...
Ink drying apparatus
Ink drying apparatus How it works: The working principle of the ink drying instrument is based on simulating the drying environment of the ink in the printing process,...
Suture Needle Penetration and Bending Strength Tester
Suture Needle Penetration and Bending Strength Tester The Suture Needle Penetration and Bending Strength Tester is a device used to test the penetration performance and strength of medical suture needl...
Rapid Crack Propagation meter
Rapid Crack Propagation meter Standard ISO 13477: Designed exclusively for determining critical pressure (Pc) and temperature (Tc) in polyethylene pressure pipes during rapid...
Putty sanding tester
Putty sanding tester Standard GB/T 1770 YC/T 315-2009 GB/T 1749-2025 Technical parameters The technical parameters of the putty sanding tester may vary from model ...
Все товары поставщика

Похожие товары

Test for Flammability of Materials ,AS1530.2,Fire reaction test apparatus
Test for Flammability of Materials ,AS1530.2,Fire reaction test apparatus Продавец: Standard International Group (HK) Limited Introduction Thistester is developed base on thestandard AS1530.2. test for flammability of mate...
Building Material Radiant Panel Test Machine,AS/NZS 1530.3
Building Material Radiant Panel Test Machine,AS/NZS 1530.3 Продавец: Standard International Group (HK) Limited Products This machine is designed according to AS/NZS 1530.3; Thedeviceviaagasradiantplatetohea...
Radiant Panel Flame Spread Apparatus,fire spread test machine
Radiant Panel Flame Spread Apparatus,fire spread test machine Продавец: Standard International Group (HK) Limited Description ASTM E162 is one most widely used test standard to evaluate the propagation properti...
Single-Flame Source Tester, ISO11925-2,DIN 53438;  DIN4102-1
Single-Flame Source Tester, ISO11925-2,DIN 53438; DIN4102-1 Продавец: Standard International Group (HK) Limited Introduction This instrument is designed according to ISO11925-2. it is used to test building ma...
Density of Smoke from the Burning or Decomposition of Plastics,ASTM D2843 Smoke Density Test
Density of Smoke from the Burning or Decomposition of Plastics,ASTM D2843 Smoke Density Test Продавец: Standard International Group (HK) Limited Introduction In a fire, people are often smoke suffocated or unable to escape because of the inv...