Sulfur Dioxide and Hydrogen Sulfide Corrosion Test Chamber for Automotive Connectors

Meeting Standards:

Carry out various sulfur dioxide gas corrosion tests in accordance with GB10587 - 89, GB2423.9 - 93, GJB150, QC/T417.1 - 2001 and equivalent standards such as IEC, DIN, MIL, ASTM.

Technical Parameters:

1. Temperature range: 10 - 55°C 2. Temperature fluctuation: ±0.5°C 3. Temperature uniformity: ±2°C 4. Sulfur dioxide gas concentration: 100ppb - 50000ppb (0.1ppm - 50ppm) 5. Hydrogen sulfide gas concentration: 10ppb - 5000ppb (0.01ppm - 5ppm) 6. Relative humidity: 75±3% 7. Tests with sulfur dioxide, hydrogen sulfide, and mixed gases of sulfur dioxide and hydrogen sulfide can be conducted.

Environmental Requirements:

1. Power supply: AC380V 3Φ 10KVA 0HZ 2. Allowable voltage range: ±5% of the rated value 3. Maximum load: 6KVA 4. The distance between the chamber and the wall should be greater than 600cm.

Structural Materials and Features:

1. The chamber is molded from epoxy fiberglass. Asbestos board is pasted inside the jacket. It is resistant to high temperature and corrosion, lightweight, and has high strength. Both the inner and outer walls of the chamber are smooth and easy to clean. 2. The chamber cover is made of epoxy fiberglass with a top cover temperature of 100 - 200°C to prevent condensed water in the chamber from dripping directly onto the test specimens. 3. Heater: The nickel - chromium alloy heating wire heats from the bottom, forming jacket heating to ensure good temperature uniformity inside the chamber. 4. Humidification method: Humidification by a steam generator. 5. Input methods for sulfur dioxide and hydrogen sulfide: Input from cylinders, and both input and discharge are quantitatively controlled by concentration sensors. 6. Exhaust gas treatment: Install treatment devices for sulfur dioxide and hydrogen sulfide gases. After multi - stage treatment with sodium bicarbonate, the exhaust gas meets the discharge standards (the purification device is external).

Control System:

1. Temperature control: Japanese Fuji temperature controller 2. Temperature input: PT100; Output: Driven by SSR 3. Display range: 0 - 100°C 4. Control range: RT + 5 - 55°C 5. Cycle used (measurement filtering): 2 - 3s 6. The main control components are products from joint - venture companies. 7. The temperature is controlled by a solid - state relay, with stable performance and no noise. 8. A fan is used for stirring and circulation inside the chamber. 9. Display and control of sulfur dioxide concentration


Отправить запрос, связаться с поставщиком

Кому: Qinsun Instruments Co., LTD
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

Wet Microbial Penetration Tester
Wet Microbial Penetration Tester The wet microbial penetration tester is mainly used to evaluate the barrier ability of medical protective equipment (such as surgical gowns, isolat...
Catheter Airflow Resistance Tester
Catheter Airflow Resistance Tester Compliance Standards YY0461 - 2003. etc. Main Uses The catheter airflow resistance tester is an important tool for evaluating the resistance of ...
Textile water evaporation rate tester
Textile water evaporation rate tester Standard: The design and operation of this tester are aligned with key international and national standards related to assessing the moisture mana...
Aerosol Foams Flammability Test device
Aerosol Foams Flammability Test device Product Introduction This product complies with "Recommendations on the Transport of Dangerous Goods - Manual of Tests and Criteria" 31.6 Flammabi...
UV Lamp Aging Test Tester
UV Lamp Aging Test Tester This product uses fluorescent UV lamps, combined with temperature and humidity device to simulate the material decline in color, brightness, streng...
Все товары поставщика

Похожие товары

Optical Brightener OB-1 (OBA 393)
Optical Brightener OB-1 (OBA 393) Продавец: Jinan Ogilvy Chemical Co., Ltd Chemical Name: 2-[(Ethylsulfanyl)methyl]phenyl methylcarbamateC.I.: 393CAS: 1533-45-5Molucular Fo...
PH-A63 Waterproof PH/EC/Temperature Meter
PH-A63 Waterproof PH/EC/Temperature Meter Продавец: Коллирон электроникс лимитед Model PH-A63 Range PH ~14.00PH EC 0~19.99mS/c...
PH-A6 Waterproof pH and Temperature Meter
PH-A6 Waterproof pH and Temperature Meter Продавец: Коллирон электроникс лимитед Model PH-A6 Range PH ~14.00PH Temp 0~50℃ ...
PH-A8PH-A8 Waterproof Soil PH Meter Waterproof Soil PH Meter
PH-A8PH-A8 Waterproof Soil PH Meter Waterproof Soil PH Meter Продавец: Коллирон электроникс лимитед Model PH-A8 Range PH ~14.00PH Temp 0~50℃ ...
TH021WIFI Internet of Things TEMP&HUMIDITY Controller
TH021WIFI Internet of Things TEMP&HUMIDITY Controller Продавец: Коллирон электроникс лимитед Product description: The electronic thermostat can be used for a variety oftemperature control...