.

Point-to-point Resistance Tester EN 1149?1?1995 GB/T 1410?2006

Standards

GB12014-2009. GB/T 1410-2006. ASTM D257-99. GB/T 10581?2006. GB/T 1692?2008. GB/T 2439?2001. GB/T 12703.4?2010. GB/T 10064?2006. GB/T 22042?2008. EN 1149?1?1995. GB/T 1410?2006.

Introduction

The point-to-point resistance tester is used to detect the point-to-point resistance rate of anti-static work clothes, which is suitable for class A and b-class anti-static work clothes. The principle is to add test voltage 100 V to test samples for total 15 s. The weak current flowing through the sample is sampled and amplified by the standard resistance and read on the high impedance meter. The figures show the resistance value directly, with high accuracy, quick display, good stability and easy reading.

Operation Principle

According to ohm's law, the tested resistance Rx is equal to the applied voltage V divided by the current I. The traditional high impedance meter works by measuring the fixed voltage V, and the resistance value is get by measuring the current I that flows through the sampling resistor. As can be seen from the ohm's law, since the current (I) is inversely proportional to the resistance rather than directly proportional, so the display value of resistance is nonlinear. Namely when the resistance is infinite, the current is zero, and the zero level at the header is ∞. The scale interval is very close with a very low resolution, so the whole scale is nonlinear. The voltage V also changes due to the measurement of different resistance, so the normal high resistance meter is low in accuracy with low resolution.

The point-to-point resistance tester measures the voltage V at the two ends of the resistance and the current I flowing through the resistor at the same time. Through the large scale integrated internal circuit, the calculation of voltage divided by the current is completed. Then, the results obtained through A/D conversion shows digital resistance value. Even though the voltage V at the two ends of the resistance and the current I flowing through the resistor change at the same time, the displayed resistance value will not change like the ordinary high resistance meter subject to the change of the tested voltage V and the current I. So, even if the measured voltage, the measured resistance and power voltage change, it has a little influence on the results. The accuracy is very high (patent), and theoretically the error can be zero, and the actual error can achieve parts per thousand or parts per ten thousand.

Technical Parameters

Items Parameters
Range limit 105Ω-1013Ω
High resistance meter indication error ±1%
Voltage 100V DC
Display mode Digital LCD
Operation environment Temperature: 0-40℃; Relative humidity: 80%
Power supply AC 220V 50Hz, power consumption about 5W
Dimension 252mm*265mm*100mm
Net weight About 5W

Отправить запрос, связаться с поставщиком

Кому: Шанхайская компания Qianshi Precision Electromechanical Technology Co., Ltd
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

Extremely High - Temperature Pre - treatment Chamber for Safety Helmets
Extremely High - Temperature Pre - treatment Chamber for Safety Helmets Extremely High - Temperature Pre - treatment Chamber for Safety Helmets - Other test instrument - standard Standards: GB/T2812-2019 Applic...
Wet leakage current test system of photovoltaic module
Wet leakage current test system of photovoltaic module Standard IEC 61215: Terrestrial Photovoltaic (PV) Modules – Design Qualification and Type Approval UL 61730: Safety Standard for Photovolta...
Residual Ethylene Oxide Gas Chromatograph
Residual Ethylene Oxide Gas Chromatograph The ethylene oxide residual gas chromatograph is a professional analytical instrument for detecting the residual amount of ethylene oxide in medica...
Tibial Tray Fatigue Testing Machine
Tibial Tray Fatigue Testing Machine Standard YY/T 0810 (China): Specifies fatigue testing protocols for tibial trays in total knee arthroplasty, focusing on support and protection ...
Oil-Water Separation Tester
Oil-Water Separation Tester Applicable Standards: (1)ISO/ TS 16332-2006 Diesel engine diesel filters Fuel Water Separation Efficiency Assessment Method. (2) ISO 4020-2001 Te...
Все товары поставщика

Похожие товары

FH-77 Dissolved hydrogen meter
FH-77 Dissolved hydrogen meter Продавец: Коллирон электроникс лимитед Pen type dissolved hydrogen detector / dissolved hydrogen meter: used to measure the dissolved hy...
Xenon Arc Weather Ometer
Xenon Arc Weather Ometer Продавец: Standard Group (Hong Kong) Limited Get a quote: Whats/App: +86 181 0160 0864 SI4000Xenon Arc Weather Ometer utilizes a xenon lamp ...
Xenotest | Light Fastness Tester Si220 (SunTest)
Xenotest | Light Fastness Tester Si220 (SunTest) Продавец: Standard Group (Hong Kong) Limited Get a quote: Whats/App:+86 180 0160 0864 A Light Fastness Tester, or Xenon Tester, Accelerated ...
Ozone Aging Chamber
Ozone Aging Chamber Продавец: Standard Group (Hong Kong) Limited Get a quote: Whats/App:+86 156 1874 6768 The Ozone Aging Chamber is a precision testing instrum...
Plastic Smoke Density Tester F313
Plastic Smoke Density Tester F313 Продавец: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com The F313 Plastic Smoke Density Tester is ...