Protective Clothing Synthetic Blood Penetration meter

Introduction It is applicable to the resistance of the protective clothing to the synthetic blood penetration under different levels of test pressure. Standard GB 19082-2003《Medical disposable protective clothing technology requires synthetic blood penetration test method》; ASTM F1670 / F1670M - 17a Standard Test Method for Resistance of Materials Used in Protective Clothing to Penetration by Synthetic Blood working principle Under constant pressure, the synthetic blood was tested on the protective clothing material, and the penetration of blood was synthesized on the visual inspection material. Sample preparation In the sample of each protective suit, 3 pieces (75*75) mm are randomly selected. When conducting the experiment on the composite or multi-layer materials, the edges should be sealed and the diameter shoud be kepted greater than 57mm for testing. Instrument characteristics 1. The instrument adopts the air source which can provide (0.5---30 + 0.1)kPa pressure to continuously pressurize the sample, and is not subject to the space limitation of the test site; 2. The range of air pressure can be set freely and set range (0.5---30)kPa; 3. Color touch screen display, Chinese and English operation menu, user can freely choose the language operation; 4. The sample surface is made of imported special aluminum profiles, with light material, smooth surface and never rust; 5. The instrument adopts imported special aluminum drawing panel with metal buttons; 6. The instrument is equipped with a sample automatic clamping device without manual clamping; 7. The test tank is equipped with special fixed device to facilitate customer operation; 8. The test tank is made of high quality 316 stainless steel, with high transparent and high intensity protective cover. 9. Square metal block: open space is more than 50%; Under 30kPa, the bending is less than 5mm; 10. The precision of instrument time control is less than 0. 1 second; 11. High quality metal baking paint is used for the whole machine shell. Technical Parameters 1. Pressure range and measurement accuracy: 0 ~ 0.04MPa (4mH2O) (31.4kg) accuracy: + 1kPa. 2. Sample size: 75mm * 75mm, under pressure area: 28.26 square centimeters. 3. Power supply: AC220V, 50Hz, 100W.
Другие товары поставщика
|
|
Multiphase High - temperature and High - pressure Explosion Limit Tester |
Reference Standards:
EN 1839 ASTM E918 ASTM E2079 EN 15967 UL9540A
Product Features:
Technical parameters:
Operating Environment
(... |
|
|
Geosynthetic direct shear drawing friction tester |
Meet the standard:
Direct shear test :IS0 12957.1,GB/T 17635.1-1998,JTG E50 T1129,SL/T 235, etc
Pull test :JTG E50 T1130,SL/T 235, etc.
Instru... |
|
|
White Body Rigidity Test Stand |
The whole system of loading and testing process can achieve automation, intelligent to meet the different models of body detection. The test system... |
|
|
Nonwovens liquid loss tester |
Nonwovens liquid loss tester built-in loss of Taiwan and sample fixture for non-woven fabric materials for a specific test fluid slip and loss of p... |
|
|
Automobile wire corrugated pipe drag grinding machine |
Applicable standards:
ISO 6722, QC/T730, JIS C 3046, JASO D 611, SAEJ1128-2005, JBT 8139,TBT 1484.1-2001 Part1, EN50305, EN50306and other standard... |
Все товары поставщика
Похожие товары