Automotive wire cyclic bending testing machine

Standard

This testing machine aligns with global automotive industry standards for wire harness reliability, includingISO 6722(Road vehicles – Cables for conductor sets) andSAE J1128(Low-voltage battery cable specifications). By simulating repetitive bending stresses, it evaluates wire fatigue resistance under dynamic conditions, ensuring compliance with OEM specifications for in-vehicle wiring durability.

Product Advantages

Versatile Angle Adjustment: Swings up to 180° bi-directionally or any user-defined angle, accommodating sharp-bend (e.g., R3.75) and gradual-curve testing scenarios.

  1. Triple-Station Efficiency: Three independent test channels enable parallel testing of different wire specifications, tripling throughput compared to single-station machines.
  2. Precision Fatigue Analysis: ±1 cycle/min speed control and 6-digit counter ensure accurate life-cycle prediction, critical for validating warranty periods.
  3. Adaptive Fixture System: Interchangeable R-angle fixtures (R3.75. R7.2. R9.6. etc.) cater to wires from thin gauge (0.5mm²) to heavy-duty cables, eliminating costly retooling.
  4. Safety & Data Integrity: Automatic stop-on-break function prevents post-failure damage, while memory retention resumes testing after power interruptions.

Product Features

  • Dynamic Swing Mechanism: 180° rotation with adjustable angles (1° increments) via digital control panel.
  • Variable Speed Control: 10–60 cycles/minute operation with real-time speed display and over-speed protection.
  • Modular Test Stations: Three channels with individual start/pause controls and LED status indicators.
  • Load Configuration: Four precision weights (2.5N, 3.75N, 5N, 7.5N) for simulating varying vibration/flexure stresses.
  • Diagnostic Capabilities: Built-in 24V test voltage output for continuity monitoring during bending cycles.
  • Robust Construction: 50KG steel frame with vibration-damping feet ensures stable operation at maximum load.

Technical Parameters

ParameterSpecification
Swing Angle Range 0°–180° (CW/CCW), adjustable in 1° increments
Operating Speed 10–60 cycles/min (±1 cycle tolerance)
Cycle Counter 1–999,999 counts (presettable with pause/resume)
Test Stations 3 independent channels with quick-release fixtures
Applied Loads 2.5N, 3.75N, 5N, 7.5N (interchangeable weights)
Fixture R-Angle Options R3.75, R7.2, R9.6 (customizable per AWG/mm²)
Test Voltage 24V DC (built-in supply)
Power Input AC 220V ±10%, 50/60Hz (switchable to DC 24V/5A)
Machine Dimensions (W×D×H) 600 × 450 × 750 mm
Net Weight 50 kg

Send product request

To: Standard International Group (HK) Limited
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Manual Tear Strength Tester
Manual Tear Strength Tester I. Product Overview TheManual Tear Strength Testeris a precision instrument designed to measure the tear resistance of materials using standardi...
Semi-automatic tank cleaning system for IBC
Semi-automatic tank cleaning system for IBC Main Functions: Interior cleaning of IBC totes The interior of a container is cleaned using a rotating cleaning head. The cleaning head is insert...
Industrial chillers
Industrial chillers Applicable Standards Industrial chillers adhere to global safety and performance regulations, including: ASHRAE 15(Safety Standard for Refrig...
 Automotive Wires Liquid Resistance Tester-QINSUN
Automotive Wires Liquid Resistance Tester-QINSUN Test Standards: Requirements for liquid resistance tests of automotive wires in ISO 6722. SAE J1128. QC/T 730. and JASOD611 Main Parameters: T...
The non-contact color measuring instrument
The non-contact color measuring instrument Applicable Standards ISO 105 A11 ASTM D1925 ASTM E313 Application Scope The non-contact color measuring instrument for textiles is suitable fo...
All supplier products

Same products

Briefly describe the importance, core functionality and how to implement a hospital clock system solution
Briefly describe the importance, core functionality and how to implement a hospital clock system solution Seller: California Triangle In the healthcare industry, precise time synchronization is critical. Every second can be a matte...
Sand and Dust Test Chamber for Automotive Connectors
Sand and Dust Test Chamber for Automotive Connectors Seller: Standard International Group (HK) Limited Operating Conditions: Ambient temperature: 5°C~+28°C (average temperature within 24 hour...
Automotive Connector SO₂/H₂S Corrosion Test Chamber
Automotive Connector SO₂/H₂S Corrosion Test Chamber Seller: Standard International Group (HK) Limited Standards: GB/T 10587-89. GB/T 2423.9-93: Chinese national standards for sulfur dioxide corrosio...
Automotive Connectors Salt Spray Tester
Automotive Connectors Salt Spray Tester Seller: Standard International Group (HK) Limited Applicable Standards: Neutral Salt Spray (NSS) Tests: GB/T2423.17. ISO 3768/3769/3770. ASTM B117...
Air - tightness Testing Device for Automotive Connectors
Air - tightness Testing Device for Automotive Connectors Seller: Standard International Group (HK) Limited Main Functions: 1. Provide stable positive and negative pressures for testing the air - tightnes...