Perdenser® Embolic Coil System
Embolic Coil. Neurovascular medical device. Applied for endovascular embolization.
Perdenser® Embolic Coil System Details
Perdenser® Embolic Coil System provides different softness with better compliance.
Anti-unwinding structure prevents coil from unwinding which is caused by over-stretching during the embolization process.
Markers on proximal end of the coil and the distal end of the delivery shaft provide accurate positioning.
Stable detachment leads to safer operation. One single coil could be detached completely within 1 second.
This product is compatible with most of the microcatheters in the market.
Product Description
A cerebral aneurysm is a bulging, weakened area in the wall of an artery in the brain, resulting in an abnormal widening, ballooning, or bleb.
Perdenser® Embolic Coil System is indicated for the endovascular embolization of intracranial aneurysms and other neurovascular abnormalities such as arteriovenous malformations and arteriovenous fistulae.
Product Features
Full Range of Sizes for Accurate Positioning
Full range of sizes of coils with both helical and complex structures. The coil system is compatible with 0.0165"-0.021" microcatheter inner diameter. Two markers design provides accurate positioning for both delivery system and detaching point.
Multi-segments Delivery System
The delivery system is designed with gradient hardness, which provides stiff proximal part and soft distal part. The longer soft segment combines with shorter detaching segment enhances the flexibility of the delivery system to go through the tortuous vessels smoothly. The stiff proximal shaft provides better pushability for easier manipulation.
Strengthen Anti-unwinding Force
The maximum anti-unwinding force could reach up to 0.5N that provided by the polymer anti-unwinding system, which guarantees its performance for coil readjustment.
Soft Shrunken Distal Loops
Pt-W alloy coil and round polymer tip enhance its softness. The first loop of the coil is shrunken to minimize the risk of coil prolapsing.
Uniform and Compact Filling Performance
Optimized Ω open loop design provides random deflecting points to fit any shape of aneurysm. The coil spreads out to any direction to form a stable frame, and advances centripetally to fully fill the space.
Safe and Reliable Immediate Detaching System
The detaching point is applied with polymer wire and immediate fusing technique, which ensure the detachment finishing within 1 second. The distal end of the coil is smooth and soft after detachment without any additional residues. The operation of the detachment is easy, stable, and safe.
Indications for Use
• Advice on taking out Perdenser from its protection scroller: pull back the black cap around 6-8cm until the delivery pusher is revealed. Do not breakoff the black cap.
Specifications - Helical Coil Structure
Specification |
Loop Dia.(mm) |
Length(cm) |
Coil Structure |
2 |
Helical |
||
3 |
Helical |
||
4 |
Helical |
||
TJCST0201-2D |
2 |
1 |
Helical |
TJCST0202-2D |
2 |
2 |
Helical |
TJCST0203-2D |
2 |
3 |
Helical |
TJCST0204-2D |
2 |
4 |
Helical |
TJCST0206-2D |
2 |
6 |
Helical |
TJCST0208-2D |
2 |
8 |
Helical |
2 |
Helical |
||
4 |
Helical |
||
6 |
Helical |
||
8 |
Helical |
||
TJCST0304-2D |
3 |
4 |
Helical |
TJCST0306-2D |
3 |
6 |
Helical |
TJCST0308-2D |
3 |
8 |
Helical |
TJCST0310-2D |
3 |
10 |
Helical |
TJCST0312-2D |
3 |
12 |
Helical |
6 |
Helical |
||
8 |
Helical |
||
10 |
Helical |
||
12 |
Helical |
||
TJCST0404-2D |
4 |
4 |
Helical |
TJCST0406-2D |
4 |
6 |
Helical |
TJCST0408-2D |
4 |
8 |
Helical |
TJCST0410-2D |
4 |
10 |
Helical |
6 |
Helical |
||
8 |
Helical |
||
10 |
Helical |
||
12 |
Helical |
||
15 |
Helical |
||
TJCST0509-2D |
5 |
9 |
Helical |
TJCST0510-2D |
5 |
10 |
Helical |
TJCST0515-2D |
5 |
15 |
Helical |
TJCST0520-2D |
5 |
20 |
Helical |
TJCST0610-2D |
6 |
10 |
Helical |
TJCST0611-2D |
6 |
11 |
Helical |
TJCST0615-2D |
6 |
15 |
Helical |
TJCST0620-2D |
6 |
20 |
Helical |
TJCST0715-2D |
7 |
15 |
Helical |
TJCST0720-2D |
7 |
20 |
Helical |
TJCST0730-2D |
7 |
30 |
Helical |
TJCST0815-2D |
8 |
15 |
Helical |
TJCST0820-2D |
8 |
20 |
Helical |
TJCST0830-2D |
8 |
30 |
Helical |
TJCST0920-2D |
9 |
20 |
Helical |
TJCST0930-2D |
9 |
30 |
Helical |
TJCST1020-2D |
10 |
20 |
Helical |
TJCST1030-2D |
10 |
30 |
Helical |
TJCST1130-2D |
11 |
30 |
Helical |
TJCST1230-2D |
12 |
30 |
Helical |
TJCST1330-2D |
13 |
30 |
Helical |
TJCST1430-2D |
14 |
30 |
Helical |
TJCST1530-2D |
15 |
30 |
Helical |
TJCST1630-2D |
16 |
30 |
Helical |
TJCST1830-2D |
18 |
30 |
Helical |
TJCST2030-2D |
20 |
30 |
Helical |
Notice: Please contact the sales for detailed information before placing the order.
Today, Lepu Medicalhas grown into a global leading medical technology company in the fields of cardiovascular interventions, structural heart diseases, cardiac rhythm management, anesthesia and critical care, in vitro diagnostics and general surgery with products include coronary stents, dilatation balloon catheters, interventional accessories, occlusion devices, mechanical heart valves, electrophysiology catheters, pacemakers, in vitro diagnostic equipment and biomarkers, DSA systems and surgical staplers. In 2009 LepuMedical successfully went public, and was listed on Chinext Shenzhen StockExchange Market ( stock code: 300003).
Отправить запрос, связаться с поставщиком
Другие товары поставщика
Single Use Disposable Trocar and Veress Needle | 45° Sleeve Tip Bevel Navigate Thread Sealing Better Application: Lepu Medical disposable trocarare suitable for establishing the wo... | |
Enoxacin | Enoxacin Item/Code CAS No. Therapeutic Area Certification/Stage Enoxacin 84294-96-2 Antibiotics U... | |
Digital Subtraction Angiography System | DSADigital Subtraction Angiography An overall solution from interventional equipment to operation devices, help hospitals co-construction individu... | |
1st Generation Disposable Endoscopic Articulating Linear Stapler and Cartridge | Standard/short type of endocutterdevice Straight/rotatable type of cartridge Four staple heights avail Product Features Over 10cm Exclusive S... | |
CFMS LEPU-8880 | Features Fast, accurate, convenient and intelligent. Evaluate the prenatal prothrombotic state and prepare the essential treatment as early as ... |
Похожие товары
Micronized Polyethylene Wax for Pigment Dispersant | Продавец: Syntop chemical Co.,Ltd. | Polypropylene wax is a chemical produced by pyrolysis, cut by heating and crushed by hot air It i... | |
cuba Резервуар для подачи жидкого азота Криогенная колба Дьюара KGSQ | Продавец: Henan Tianzhidao Biological Technology Co., Ltd. | В исследованиях в области медико-биологических наук жидкий азот является широко используемой замо... | |
Specification: 0.08mm-4mm | Продавец: Changzhou Yuzisenhan Electronic Co., Ltd | Changzhou Yuzisenhan Electronic Co., Ltd. has convenient transportation in Wujin District, Changz... | |
Контейнер для заморозки ячеек Того KGSQ Полевой резервуар с жидким азотом | Продавец: Хэнань Тяньчжидао Биотехнология Лтд. | Использование резервуаров с жидким азотом охватывает научные исследования, животноводство, делика... | |
White Fiberglass Surface, Packaging Type: Roll at | Продавец: Jiangsu Zeyusen Carbon Fiber Technology Co., Ltd. | Fiberglass surface mat is mainly used in the surface layer of fiberglass merchandise, it has th... |