EJA118W Diaphragm SeaLED Differential Pressure Transmitters

EJA118W Diaphragm Sealed Differential Pressure TransmittersFeatures :Diaphragm seals are used to prevent process medium form entering directly into the pressure-sensing assembly of thedifferential pressure transmitter,Website:, they are connected to the transmitter using capillaries filled with fill fluid. Standard Specifications : Measurement Ranges:Capsule Measurement Span Measurement Range M 2.5 to 100 kPa -100 to 100 kPa {-10000 to 10000 mmH2O} {250 to 10000 mmH2O}H 25 to 500 kPa -500 to 500 kPa {-5 to 5 kgf/cm2} {0.25 to 5 kgf/cm2} Output Signal “”:4 to 20 mA DC, 2-wire system with digital communication Failure Alarm:Output status at CPU failure and hardware error;Up-scale: 110%, 21.6 mA DC or more(standard)Down-scale: -5%, 3.2 mA DC or less-2.5%, 3.6 mA DC or less (Optional code /F1)Note: Applicable for Output signal code D and E Supply Voltage “”:10.5 to 42 V DC for general use and flameproof type10.5 to 32 V DC for lightning protector (Optional code /A)10.5 to 30 V DC for intrinsically safe, Type n, nonincendive,or non-sparking type10.5 to 28 V DC for TIIS intrinsically safe type Conditions of Communication Line “”:Power supply voltage;16.4 to 42 V DCLoad resistance; See Figure 1.Note: In case of an intrinsically safe transmitter, externalload resistance includes safety barrier resistance.Communication distance;2 km, when CEV polyethylene-insulatedPVC-sheathed control cables are used.Note: Communication distance varies depends on kind ofcable.Load capacitance; 0.22 µF of less.Load inductance; 3.3 mH or less.Spacing from power line; 15 cm or more.Input impedance of receiver connected receiving resistance;10 k or more at 2.4 kHz(See Optional Specifications for Intrinsically safe type) Technical parameters : Products show : Why chose us :
Другие товары поставщика
|
|
|
3051T In-Line Pressure TransmitterFeature :Pressure transmitter is made on both sides of the diaphragm and the measuring ele... |
|
|
|
2088 Pressure TransmitterFeature :Proven Reliability for Gage and Absolute Applications• Available protocols include 4-... |
|
|
|
Bourdon tube pressure gauge safety version 232.30,Website:, 233.30 Applications■ Increased safety requirements■ With liquid-filled case for ap... |
|
|
|
UE pressure switch H100-183 H-184 H100-185Feature :Pressure switch main categories include normally open and nor... |
|
|
|
24 Series UE pressure Switch overview:The cost-effective 24 Series Delta-Pro™ pressure,Website:, vacuum, and differe... |
Все товары поставщика
Похожие товары