HM-200 Hygronom

Overview

Hygronom is used to measure the humidity of flue gas emitted by pollution sources. According to measured humidity, it converts wet gas concentration into dry gas concentration. In addition, it also can be used in industrial online humidity monitoring.

HM-200 hygronom (online precision humidity meter) is an intelligent humidity/ oxygen transmitter, which employs microprocessor as the core, and frequency conversion icon oxygen sensor as a measuring unit. The installation method adopts a heat tracing pipeline installation. It is a self-developed product, of which, the core component is from Switzerland.

Under the effect of the air pump, the flue gas inside the stack enters the measurement module after heating from the heat tracing probe. The whole process of extraction, measurement, and discharge is with heat tracing to prevent gas from condensation, which will affect the measurement of moisture in the flue gas. The flue gas enters the measurement module after heating and the frequency conversion icon oxygen sensor will start to measure gas concentration. After the measurement, the gas can get into an analyzer for the measurement of other components.

Features Of HM-200 Hygronom

Portable structure, easy to install and disassemble

Able to measure the humidity of 300℃ flue gas

Able to match with the large-scale system for measurement or independent measurement

The probe is equipped with heat tracing function to prevent condensate water from damaging probe and affecting measuring value

Imported core components with high-performance index and reliability

Technical Parameter Of HM-200 Hygronom

Measurement range

O2: 0~25.00%, H2O: 0~40.00% (volume ratio )

Sensor

Frequency conversion icon oxygen sensor (2)

Accuracy

0~1% O2:±1.5%F.S.

0~25% O2:±1.5% of measured value

0~40.00% H2O:±1%F.S.

Stability

0~1% O2:±1.5%F.S./7d

0~25% O2:±1.5%/7d of measured value

0~40.00% H2O:±1%F.S./7d

Response time

T90<30s

Sensor life

>2 years (under normal use)

Transmitter life

>5 years (under normal use)

Power supply

24VDC

Instrument weight

Net weight about 2.25kg (include operation panel)

Ambient temperature

Transmitter: -10°C~+50°C

Probe: 0~300℃ (except probe cable)

Ambient humidity

<85%RH

Power consumption

Maximum about 35VA (heating)

Under normal working: 30~31W

Sample gas flow

(2~6)L/min

Analog output (2 sets)

Settable 4-20mA, 0-20mA, 0-1-5-10V, 1-5V

Communication

Rs485 (standard)/RS232 (optional)

Application Of HM-200 Hygronom

It can be widely applied in high-temperature (300℃) gas (such as desulfuration and denitration) humidity measurement of Continuous Emission Monitoring System (CEMS), humidity measurement and control in fields including wood, building material, papermaking, chemical industry, fiber, pharmacy, textile, tobacco, vegetable and food processing.

We provide air quality monitor,humidity meter onlineand professional humidity meter,RFQ today.



Отправить запрос, связаться с поставщиком

Кому: Ханчжоу Zetian Technology Co., Ltd.
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

Continuous Emission Monitoring & Process Control
Continuous Emission Monitoring & Process Control The instruments and analyzers produced by Zetian now are widely used at home and abroad. They are: UV DOAS gas analyzer, laser TDLAS gas analyzer, ...
Humidity Analyzer
Humidity Analyzer Hygronom is also called moisture meter or dew-point meter, which is used to measure humidity of flue gas emitted by pollution source. According to ...
AM-5100 SO2 Analyzer
AM-5100 SO2 Analyzer Overview AM-5100 SO2 analyzer adopts ultraviolet fluorescence technique and combines advanced micro processing technology, which could provide accu...
FT-2000P Portable FTIR Gas Analyzer
FT-2000P Portable FTIR Gas Analyzer Overview Based on FTIR technology, FT-2000P portable gas analyzer can continuously monitor various kinds of components in the emission, such as SO2...
EQMS-200 VOCs Online Monitoring System
EQMS-200 VOCs Online Monitoring System Overview EQMS-200 VOCs online monitoring system adopts PID (photoionization detector ) for gas detection. The target gas is irradiated I bombarded ...
Все товары поставщика

Похожие товары

Shoes Flexing Tester
Shoes Flexing Tester Продавец: Тысяча сплошная точный электромеханический прибор контрольно-измерительной ЛТД TRANSLATE with x English Arabic Hebrew Polish Bulgarian Hindi ...
Shoelace Abrasion Tester
Shoelace Abrasion Tester Продавец: Тысяча сплошная точный электромеханический прибор контрольно-измерительной ЛТД TRANSLATE with x English Arabic Hebrew Polish Bulgarian Hindi ...
Heel Fatigue Tester
Heel Fatigue Tester Продавец: Тысяча сплошная точный электромеханический прибор контрольно-измерительной ЛТД TRANSLATE with x English Arabic Hebrew Polish Bulgarian Hindi ...
Heel Impact Tester
Heel Impact Tester Продавец: Тысяча сплошная точный электромеханический прибор контрольно-измерительной ЛТД TRANSLATE with x English Arabic Hebrew Polish Bulgarian Hindi ...
Ross Flex Tester
Ross Flex Tester Продавец: Тысяча сплошная точный электромеханический прибор контрольно-измерительной ЛТД TRANSLATE with x English Arabic Hebrew Polish Bulgarian Hindi ...