Intrinsic Isolated Barrier
What Is Isolation Barrier?
Intrinsic safety barriers and isolatorsuse intrinsically safe explosion-proof and functional safety technologies and adopts various measures such as rapid cut-off, isolation, and energy limiting to ensure that the energy transmitted to the field equipment in the hazardous area is intrinsically safe, thereby preventing dangerous energy from entering the danger zone and causing an explosion.
An isolation barrier, such as the digital input barrier, is a key interface unit in the intrinsically safe explosion-proof control system. The intrinsically safe barrier or the intrinsic safety barrier with quite affordable price made by CHENZHU, one of the top intrinsic safety barrier manufacturers in China, is made under a strict production process and tested by a series of quality assurance systems.
IS Barrier Types
GS8500-EX Series Intrinsic Safety Barrier
GS8500-EX Analogue Intrinsic Safety Barrier
GS8500-EX Analogue Intrinsic Safety Barrier Loop Power
GS8500-EX Digital Intrinsic Safety Barrier
GS8500-EX Digital Intrinsic Safety Barrier Loop Power
GS8500-EX Temperature Converter Intrinsic Safety Barrier
GS8500-EX Voltage Input Intrinsic Safety Barrier
GS8500-EX Communication Input Intrinsic Safety Barrier
GS8500-EX Frequency Converter Intrinsic Safety Barrier
GS5000-EX Series Intrinsic Safety Barrier
GS5000-EX Analogue Intrinsic Safety Barrier
GS5000-EX Analogue Intrinsic Safety Barrier Loop Power
GS5000-EX Digital Intrinsic Safety Barrier
GS5000-EX Digital Intrinsic Safety Barrier Loop Power
GS5000-EX Temperature Converter Intrinsic Safety Barrier
GS8200-EX Series Intrinsic Safety Barrier
GS8200-EX Analogue To RS485 Intrinsic Safety Barrier
LBGS8000-EX Series Surge Protective Intrinsic Safety Barrier
GS4000-EX Series Backplane Intrinsic Safety Barrier
What is Difference Between Intrinsic Isolated Barrier and Intrinsically Safe Isolator?
Isolator
The isolator is used to adjust, isolate and transform all kinds of field instrument signals into the normal signals or special signals specified by users which can be accepted by the computer, DCS, PLS, etc. It is also used to isolate control equipment and operational equipment from electronics, like a relay.
Intrinsic isolated barrier
The isolated barriers for hazardous areas in our safety automation system for sale are associated equipments of explosion-proof instruments that will not affect the function of the measurement system in a normal situation. The isolation barrier is placed on one side of the security site, when the explosion-proof system fails, the intrinsic barriercan limit the energy (electric energy) which can enter the dangerous site to safe values to ensure the safety of the scene.
Difference
What is Safety Level of Intrinsically Safe Electrical Equipment?
IA
IA means that the explosive gas mixture cannot be ignited under normal operation, one counting failure, and two counting failures. IA-level intrinsically safe electrical equipment can be used in hazardous locations in Zone 0, Zone 1, and Zone 2.
IB
IB means that explosive gas mixtures cannot be ignited under normal operation and a counting failure. IB's intrinsically safe electrical equipment that can be used in hazardous locations in Zone 1 and Zone 2.
IC
IC means that explosive gas mixtures cannot be ignited under normal operation. IC-level intrinsically safe electrical equipment can be used in zone 2 hazardous locations.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Temperature Transmitter | CHENZHU, a reliable temperature transmitter manufacturers, provides a large range of head-mounted temperature transmitters at an affordable price. ... | |
| AC Power SPD | AC SPD The power surge protector for ac compressoris designed to prevent transient surge conditions. Large single surge events, such as lightning,... | |
| Photovoltaic 1000 DC Power SPD | Photovoltaic DCSPD1000 Signal SPDfor DC power, 1000VDC; In(8/20us): 20kA/phase, Imax: 40kA/phase; hot-pluggable; fault indication; Features &am... | |
| Photovoltaic 1000 DC Power SPD | SPD for DC power, 1000v spd; In(8/20us): 20kA/phase, Imax: 40kA/phase; hot-pluggable; fault indication; Features & Advantages of Photovoltai... | |
| Safety Relay | SHANGHAI CHENZHU INSTRUMENT CO., LTD. is a very established provider that specialises in safety and automation system. We have over 24 years of exp... |
Похожие товары
| Air insulated Dry type transformer VPI | Продавец: Power transformer | Air insulated Dry type transformer VPI TAILI SG(B) air-barrier dry-type transformer( VPI) is des... | |
| Cast Resin Dry Type Transformer with Cooling Fan | Продавец: Power transformer | Cast Resin Dry Type Transformer with Cooling Fan Taili’s advanced epoxy resin casting pr... | |
| 1250kVA Dry type Transformer for Bangladesh | Продавец: Power transformer | 1250kVA Dry type Transformer for Bangladesh Taili's advanced epoxy resin casting process ensures... | |
| 35kV Dry-type transformer with OLTC | Продавец: Power transformer | 35kV Dry-type transformer with OLTC Taili's35kV Dry-type Transformer with OLTC (On-Load Tap Chan... | |
| Cast Resin Dry Type Transformer | Продавец: Power transformer | Cast Resin Dry Type Transformer IEC/ANSICast Resin TransformersfromTAILI Electric, is difference... |