Noshok 100 Series Current Output Pressure Transmitters,615 & 616 Series High Accuracy Heavy Duty Pressure Transducers 640 Series Precision Heavy Duty Pressure Transducers with Serial Interface,660 Ser
SPECIFICATIONS
Output signal
4 mA to 20 mA, 2-wire
Pressure ranges
Standard gauge ranges from vacuum to 15,000 psi;
Standard absolute ranges from 15 psia to 300 Pisa
Proof pressure
3 times full scale for ranges 0 psi to 5 psi through 0 psi to 200 psi
1.75 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
1.5 times full scale for 0 to 15,000 psi range
Burst pressure
3.8 times full scale for ranges 0 psi to 5 psi through 0 psi to 200 psi
4 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
3 times full scale for 0 to 15,000 psi range
Accuracy
± 0.5 % full scale (BFSL);optional ± 0.25% full scale (BFSL)
(Includes the effects of non-linearity, hysteresis, non-repeatability, zero point and full scale errors)
Repeatability
≤ ± 0.05% full scale
Hysteresis
≤ ± 0.1% full scale
Stability
≤ ± 0.2% full scale for 1 year, non-accumulating
Response time
≤1 ms (between 10% and 90% full scale)
Power supply*
10 Vdc to 30 Vdc (4 mA to 20 mA, 2-wire)
Load limitations
≤ (Vpower supply - 10)/.020 Amp
Wetted materials
316 stainless steel for vacuum through 300 psi;
17-4PH stainless steel sensing diaphragm and 316 stainless steel
process connection for higher ranges
Housing materials
316 stainless steel
Adjustment
≤ ± 10% full scale for zero and span
Pressure cycle limit
150 Hz
Durability
> 100,000,000 full scale cycles
Temperature ranges
Compensated 32 °F to 176 °F (0 °C to 80 °C)
Effect ± 0.017% full scale/°F for zero and span
Ambient -40 °F to 185 °F (-40 °C to 85 °C)
Media -22 °F to 212 °F (-30 °C to 100 °C)
Storage -40 °F to 212 °F (-40 °C to 100 °C)
Environmental rating
IP65, NEMA 4X according to EN 60529/IEC 529
Electromagnetic rating
CE compliant to EMC norm EN 61326:1997/A1:1998
RFI, EMI and ESD protection
Electrical protection
Reverse polarity, over-voltage and short circuit protection
Shock
1000 g's per IEC 770
Vibration
30 g's per IEC 770
Non-linearity
≤ ±0.25% BFSL; optional ±0.125% BFSL
Weight
Approximately 3.5 oz.
• Highly repeatable, shock resistant transmitters with excellent long-term stability
• Standard ranges from vacuum to 15,000 psi; standard absolute ranges from 15 psia to 300 psia
• Accuracy up to ±0.25% full scale (BFSL)
• Compact size, affordable price
• Advanced diffused semi-conductor and sputtered thin film sensor for maximum stability
• Welded stainless steel pressure chamber
• High alternating load resistance
• High overpressure protection
• Compatible with NOSHOK Smart System Indicators
• CE compliant to suppress RFI, EMI and ESD, combined with reverse polarity and over-voltage protection to ensure reliable performance in the most demanding applications
• Final calibration tests prior to shipment ensures 100% "out of the box" reliability
PROCESS CONNECTIONS 1 1/8″ NPT Male 3 SAE J1926-3:7/16-20 Adjustable
9 SAE J1926-1:7/16-20
Noshok 200 Series Voltage Output Pressure Transducers
SPECIFICATIONS
Output signals
0 Vdc to 5 Vdc, 3-wire; 0 Vdc to 10 Vdc, 3-wire; 1 Vdc to 5 Vdc, 3-wire;
1 Vdc to 6 Vdc, 3-wire; 1 Vdc to 11 Vdc, 3-wire;
Pressure ranges
Standard gauge ranges from vacuum to 15,000 psi;
Standard absolute ranges from 15 psia to 300 Pisa
Proof pressure
3 times full scale for ranges 0 psi to 5 psi through 0 psi to 200 psi
1.75 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
1.5 times full scale for 0 psi to 15000 psi range
Burst pressure
3.8 times full scale for ranges 0 psi to 5 psi through 0 psi to 200 psi
4 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
3 times full scale for 0 psi to 15,000 psi range
Accuracy
± 0.5 % full scale (BFSL);
± 1.0% terminal point;
± 0.25 % optional (Includes the combined effects of linearity, hysteresis and repeatability)
Repeatability
≤ ± 0.05% full scale
Hysteresis
≤ ± 0.1% full scale
Stability
≤ ± 0.2% full scale per year, non-accumulating
Response time
≤1 ms (between 10% and 90% full scale)
Power supply*
10 Vdc to 30 Vdc (0 Vdc to 5 Vdc, 3-wire)
10 Vdc to 30 Vdc (1 Vdc to 5 Vdc, 3-wire)
10 Vdc to 30 Vdc (1 Vdc to 6 Vdc, 3-wire)
14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-wire)
14 Vdc to 30 Vdc (1 Vdc to 11 Vdc, 3-wire)
Load limitations
≥ 5,000 for 0 Vdc to 5 Vdc, 1 Vdc to 5 Vdc, and 1 Vdc to 6 Vdc outputs;
≥ 10,000 for 0 Vdc to 10 Vdc and 1 Vdc to 11 Vdc outputs.
Current consumption 8 mA
Wetted materials
316 stainless steel for vacuum through 300 psi;
17-4PH stainless steel sensing diaphragm and 316 stainless steel pressure connection for higher ranges
Housing materials
316 stainless steel
Adjustment
± 10% full scale for zero and span
Pressure cycle limit
150 Hz
Durability
> 100,000,000 full scale cycles
Temperature ranges
Compensated 32 °F to 176 °F (0 °C to 80 °C)
Effect ± 0.017 % full scale/°F for zero and span
Ambient -40 °F to 185 °F (-40 °C to 85 °C)
Media -22 °F to 212 °F (-30 °C to 100 °C)
Storage -40 °F to 212 °F (-40 °C to 100 °C)
Environmental rating
IP65, NEMA 4X according to EN 60529/IEC 529
Electromagnetic rating
CE compliant to EMC norm EN 61326:1997/A1:1998
RFI, EMI and ESD protection
Electrical protection
Reverse polarity, over-voltage and short circuit protection
Shock
1000 g's per IEC 770
Vibration
30 g's per IEC 770
Weight
Approximately 3.5 oz.
Другие товары поставщика
|
Fischer Contact Pressure Gauge DA08D8A040UB-600PA S1199VA00BK 0-10BAR MS1108VA00BK0000 0-16BAR 24V 0.4A Building technology 16 bar DS31,50 mbar | DS35, DE25, DE28, DE38, DE44,DE45, DE46,DE50, DE61 |
MS1199VA00BK 0-10BAR MS1108VA00BK0000 0-16BAR 24V 0.4A Specifications General Measuring range Nominal pressure Max. pressure Perm. ambient temperat... |
|
Bosch Standard Valves Compact Hydraulics model KKDER Compact Hydraulic Units |
Hydraulics Application: Directional spool valves, direct operated, with solenoid actuation (high performance) Key features: Frame sizes 1 and 8 Flu... |
|
Dwyer pressure transmitter 626/628 series |
Service: Compatible gases and liquids.Wetted Materials: Type 316L SS.Accuracy:626: 0.25% FS; 0.20% RSS;628: 1.0% FS; 0.5% RSS;626 Absolute Ranges: ... |
|
Honeywell Solenoid valves for gas, liquid gas/fuel K-series Flange connection K15G31F |
The 2/2-way valves of the K-series can be used for all gases according to DVGW-data sheet G 260, for liquid gas in liquid phase (up to DN25) and fo... |
|
Rotork Electric Actuators A Range |
AWT Range Fire Protection IQ Standard IQD DC IQH High Speed IQM Modulating IQML Linear Modulating IQS Single Phase IQT Pro Range IQT Quarter Turn I... |
Все товары поставщика