(N)TSCGEWOEU Medium-Voltage Fixed Installation Cable With Fiber Optics

(N)TSCGEWOEU Medium-Voltage Fixed Installation Cable With Fiber OpticsApplicationsThese cables are used for For laying alongside the conveyor belts (also for shiftable units)and on material handling equipment (even with continuous movementsuch as in cable booms or as connection between upperand lower car) and for connection of submersible pump units.StandardsBased on VDE 0250 Part 813ConstructionConductorsFlexible strandedcopper conductor,Website:, class 5 according to DIN VDE 0295.Inner Conductor LayerSemiconductive layer.InsulationEPR.Outer Conductor LayerSemiconductive layer.Earth ConductorSplit into two in the outer interstices.Fiber OpticsFO 50/125 or 62.5/125 orE9/125μm within protection sheath.InnerSheathEPR.Outer SheathCM.Dimensions and Weight3.6/6 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+2×25/2+1×(6LWL)40.143.126503×25+2×50/2+1×(6LWL)42.445.430603×35+2×25/2+1×(6LWL)42.345.330603×35+2×50/2+1×(6LWL)44.047.034103×50+2×25/2+1×(6LWL)43.846.834903×50+2×50/2+1×(6LWL)46.149.136403×70+2×35/2+1×(6LWL)47.050.043503×70+2×50/2+1×(6LWL)52.056.052803×95+2×50/2+1×(6LWL)52.256.255503×120+2×70/2+1×(6LWL)49.650.970403×150+2×70/2+1×(6LWL)48.452.380003×185+2×95/2+1×(6LWL)51.355.393103×240+2×120/2+1×(6LWL)58.062.0119403×300+2×150/2+1×(6LWL)63.267.2142306/10 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+2×25/2+1×(6LWL)41.444.427703×25+2×50/2+1×(6LWL)43.146.131203×35+2×25/2+1×(6LWL)43.646.631903×35+2×50/2+1×(6LWL)44.747.734703×50+2×25/2+1×(6LWL)45.148.136203×50+2×50/2+1×(6LWL)46.849.840103×70+2×35/2+1×(6LWL)48.351.345003×70+2×50/2+1×(6LWL)52.756.753603×95+2×50/2+1×(6LWL)53.557.557103×120+2×70/2+1×(6LWL)57.261.268303×150+2×70/2+1×(6LWL)62.366.381803×185+2×95/2+1×(6LWL)65.369.395003×240+2×120/2+1×(6LWL)73.477.4121603×300+2×150/2+1×(6LWL)78.682.6144608.7/15 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+2×25/2+1×(6LWL)44.247.230503×25+2×50/2+1×(6LWL)45.448.433503×35+2×25/2+1×(6LWL)45.348.333203×35+2×50/2+1×(6LWL)47.050.037103×50+2×25/2+1×(6LWL)49.453.441603×50+2×50/2+1×(6LWL)51.255.245903×70+2×35/2+1×(6LWL)52.756.750803×70+2×50/2+1×(6LWL)55.059.056403×95+2×50/2+1×(6LWL)57.061.061603×120+2×70/2+1×(6LWL)62.166.175203×150+2×70/2+1×(6LWL)65.769.786703×185+2×95/2+1×(6LWL)68.772.7100103×240+2×120/2+1×(6LWL)76.880.8127303×300+2×150/2+1×(6LWL)82.086.01508012/20 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+2×25/2+1×(6LWL)45.548.531403×25+2×50/2+1×(6LWL)47.250.235303×35+2×25/2+1×(6LWL)48.351.336403×35+2×50/2+1×(6LWL)51.055.042403×50+2×25/2+1×(6LWL)52.556.545303×50+2×50/2+1×(6LWL)52.556.546903×70+2×35/2+1×(6LWL)55.759.754603×70+2×50/2+1×(6LWL)58.062.060403×95+2×50/2+1×(6LWL)61.465.467703×120+2×70/2+1×(6LWL)65.169.179503×150+2×70/2+1×(6LWL)68.772.791303×185+2×95/2+1×(6LWL)73.277.2107703×240+2×120/2+1×(6LWL)79.883.8132603×300+2×150/2+1×(6LWL)86.391.31604014/25 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+2×25/2+1×(6LWL)50.354.337403×25+2×50/2+1×(6LWL)50.354.339003×35+2×25/2+1×(6LWL)53.157.142703×35+2×50/2+1×(6LWL)53.157.144403×50+2×25/2+1×(6LWL)56.360.350003×50+2×50/2+1×(6LWL)56.360.351603×70+2×35/2+1×(6LWL)61.065.061903×70+2×50/2+1×(6LWL)61.065.063903×95+2×50/2+1×(6LWL)65.369.373403×120+2×70/2+1×(6LWL)69.073.085503×150+2×70/2+1×(6LWL)74.078.0100203×185+2×95/2+1×(6LWL)77.081.0114103×240+2×120/2+1×(6LWL)85.090.0143803×300+2×150/2+1×(6LWL)90.295.21682018/30 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+2×25/2+1×(6LWL)53.757.741403×25+2×50/2+1×(6LWL)53.757.743103×35+2×25/2+1×(6LWL)56.660.647203×35+2×50/2+1×(6LWL)56.660.648803×50+2×25/2+1×(6LWL)61.265.256803×50+2×50/2+1×(6LWL)61.265.258403×70+2×35/2+1×(6LWL)64.468.466703×70+2×50/2+1×(6LWL)64.468.468703×95+2×50/2+1×(6LWL)68.772.778603×120+2×70/2+1×(6LWL)73.877.893503×150+2×70/2+1×(6LWL)77.581.5106303×185+2×95/2+1×(6LWL)80.584.5120403×240+2×120/2+1×(6LWL)88.593.5150703×300+2×150/2+1×(6LWL)94.799.717780
Другие товары поставщика
|
|
[FA-] MPYS, MPYCS, MPYCYS |
250V [FA-] MPYS,Website:, MPYCS, MPYCYSStandards:JISC 3410-1999IEC 60332-1IEC 60332-3 Cat.A(for FA-type)CABLE CONSTRUCTIONConductorMTinned annealed... |
|
|
LYST/LYAR airfield lighting cable |
LYST/LYARairfield lighting cable
Applications
LYST airport cables are used for connection between control tower and constant current regulators (CC... |
|
|
FAA L-824 Type B Unshielded 5kV Airport Cable |
FAA L-824 Type B Unshielded 5kV Airport Cable
Applications
These cables are used for interconnecting the transformers and the current regulator of ... |
|
|
RHZ1 Airfield Lighting Cables |
RHZ1 Airfield Lighting Cables
Applications
These cables are used as airfield lighting equipment primary cables for the series circuit connecting th... |
|
|
Кабели для аэропортов| FL2XCY Airport Cable |
FL2XCY Airport Cable
Applications
These cables are used as airfield lighting equipment primary cables for the series circuit connecting the Constan... |
Все товары поставщика
Похожие товары