(N)TSCGEWOEU Medium-Voltage Fixed Installation Cable With Fiber Optics

(N)TSCGEWOEU Medium-Voltage Fixed Installation Cable With Fiber OpticsApplicationsThese cables are used for For laying alongside the conveyor belts (also for shiftable units)and on material handling equipment (even with continuous movementsuch as in cable booms or as connection between upperand lower car) and for connection of submersible pump units.StandardsBased on VDE 0250 Part 813ConstructionConductorsFlexible strandedcopper conductor,Website:, class 5 according to DIN VDE 0295.Inner Conductor LayerSemiconductive layer.InsulationEPR.Outer Conductor LayerSemiconductive layer.Earth ConductorSplit into two in the outer interstices.Fiber OpticsFO 50/125 or 62.5/125 orE9/125μm within protection sheath.InnerSheathEPR.Outer SheathCM.Dimensions and Weight3.6/6 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+2×25/2+1×(6LWL)40.143.126503×25+2×50/2+1×(6LWL)42.445.430603×35+2×25/2+1×(6LWL)42.345.330603×35+2×50/2+1×(6LWL)44.047.034103×50+2×25/2+1×(6LWL)43.846.834903×50+2×50/2+1×(6LWL)46.149.136403×70+2×35/2+1×(6LWL)47.050.043503×70+2×50/2+1×(6LWL)52.056.052803×95+2×50/2+1×(6LWL)52.256.255503×120+2×70/2+1×(6LWL)49.650.970403×150+2×70/2+1×(6LWL)48.452.380003×185+2×95/2+1×(6LWL)51.355.393103×240+2×120/2+1×(6LWL)58.062.0119403×300+2×150/2+1×(6LWL)63.267.2142306/10 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+2×25/2+1×(6LWL)41.444.427703×25+2×50/2+1×(6LWL)43.146.131203×35+2×25/2+1×(6LWL)43.646.631903×35+2×50/2+1×(6LWL)44.747.734703×50+2×25/2+1×(6LWL)45.148.136203×50+2×50/2+1×(6LWL)46.849.840103×70+2×35/2+1×(6LWL)48.351.345003×70+2×50/2+1×(6LWL)52.756.753603×95+2×50/2+1×(6LWL)53.557.557103×120+2×70/2+1×(6LWL)57.261.268303×150+2×70/2+1×(6LWL)62.366.381803×185+2×95/2+1×(6LWL)65.369.395003×240+2×120/2+1×(6LWL)73.477.4121603×300+2×150/2+1×(6LWL)78.682.6144608.7/15 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+2×25/2+1×(6LWL)44.247.230503×25+2×50/2+1×(6LWL)45.448.433503×35+2×25/2+1×(6LWL)45.348.333203×35+2×50/2+1×(6LWL)47.050.037103×50+2×25/2+1×(6LWL)49.453.441603×50+2×50/2+1×(6LWL)51.255.245903×70+2×35/2+1×(6LWL)52.756.750803×70+2×50/2+1×(6LWL)55.059.056403×95+2×50/2+1×(6LWL)57.061.061603×120+2×70/2+1×(6LWL)62.166.175203×150+2×70/2+1×(6LWL)65.769.786703×185+2×95/2+1×(6LWL)68.772.7100103×240+2×120/2+1×(6LWL)76.880.8127303×300+2×150/2+1×(6LWL)82.086.01508012/20 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+2×25/2+1×(6LWL)45.548.531403×25+2×50/2+1×(6LWL)47.250.235303×35+2×25/2+1×(6LWL)48.351.336403×35+2×50/2+1×(6LWL)51.055.042403×50+2×25/2+1×(6LWL)52.556.545303×50+2×50/2+1×(6LWL)52.556.546903×70+2×35/2+1×(6LWL)55.759.754603×70+2×50/2+1×(6LWL)58.062.060403×95+2×50/2+1×(6LWL)61.465.467703×120+2×70/2+1×(6LWL)65.169.179503×150+2×70/2+1×(6LWL)68.772.791303×185+2×95/2+1×(6LWL)73.277.2107703×240+2×120/2+1×(6LWL)79.883.8132603×300+2×150/2+1×(6LWL)86.391.31604014/25 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+2×25/2+1×(6LWL)50.354.337403×25+2×50/2+1×(6LWL)50.354.339003×35+2×25/2+1×(6LWL)53.157.142703×35+2×50/2+1×(6LWL)53.157.144403×50+2×25/2+1×(6LWL)56.360.350003×50+2×50/2+1×(6LWL)56.360.351603×70+2×35/2+1×(6LWL)61.065.061903×70+2×50/2+1×(6LWL)61.065.063903×95+2×50/2+1×(6LWL)65.369.373403×120+2×70/2+1×(6LWL)69.073.085503×150+2×70/2+1×(6LWL)74.078.0100203×185+2×95/2+1×(6LWL)77.081.0114103×240+2×120/2+1×(6LWL)85.090.0143803×300+2×150/2+1×(6LWL)90.295.21682018/30 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+2×25/2+1×(6LWL)53.757.741403×25+2×50/2+1×(6LWL)53.757.743103×35+2×25/2+1×(6LWL)56.660.647203×35+2×50/2+1×(6LWL)56.660.648803×50+2×25/2+1×(6LWL)61.265.256803×50+2×50/2+1×(6LWL)61.265.258403×70+2×35/2+1×(6LWL)64.468.466703×70+2×50/2+1×(6LWL)64.468.468703×95+2×50/2+1×(6LWL)68.772.778603×120+2×70/2+1×(6LWL)73.877.893503×150+2×70/2+1×(6LWL)77.581.5106303×185+2×95/2+1×(6LWL)80.584.5120403×240+2×120/2+1×(6LWL)88.593.5150703×300+2×150/2+1×(6LWL)94.799.717780
Другие товары поставщика
|
|
Aluminum Conductor Steel Reinforced (ACSR) Cables |
Aluminum Conductor Steel Reinforced (ACSR) Cables
Application
ACSR conductors are widely used for electrical power transmission over long distance... |
|
|
150/250V HF-EPR Insulated, SW2/SW4 Sheathed, Collectively Screened Unarmoured Fire Resistant Instrumentation Control Cables |
150/250V HF-EPR Insulated,Website:, SW2/SW4 Sheathed, Collectively Screened Unarmoured Flame Retardant Instrumentation & Control CablesApplicat... |
|
|
PE Insulated,Website:, LSZH Sheathed & Overall Screened, Armoured Instrumentation Cables (Single Pair)RE-2Y(St)HSWAH |
PE Insulated,Website:, LSZH Sheathed & Overall Screened, Armoured Instrumentation Cables (Single Pair)RE-2Y(St)HSWAH 90°C / 300VSTANDARDSBa... |
|
|
Кабели для аэропортов| FL2XCYRY Airport Cable |
FL2XCYRY Airport Cable
Applications
These cables are used as airfield lighting equipment primary cables for the series circuit connecting the Const... |
|
|
Aerial Bundled Cables to NFC 33-209 (AL/XLPE) |
Aerial Bundled Cables to NFC 33-209 (AL/XLPE)
Application
The aerial bundled cables designed for fixed installation as overhead power lines up to 1... |
Все товары поставщика