LYST/LYAR airfield lighting cable
LYST/LYARairfield lighting cable
Applications
LYST airport cables are used for connection between control tower and constant current regulators (CCRs), suitable for transmission of voice data up to 2,000 kHz.
Standards
NF C 32 070 C2
Construction
| Conductor |
Solid bare copper. |
| Insulation |
PE |
| Cable Element |
Pairs |
| Separator |
One or more plastic tapes. |
| Shield |
Polyester-aluminium tape with drain wire. |
| Sheath |
PVC. |
Technical Data
| Rated Voltage Uo/U (Um) |
200V |
| Maximum Conductor Temperature |
90°C |
| Short Circuit Temperature |
250°C |
| Operating Temperatures |
-15°C~+70°C |
| Minimum Bending Radius |
static: 6×OD; dynamic: 12×OD |
| Lead Free |
Другие товары поставщика
|
|
FAA L-824 Type C 600V Airport Cable |
FAA L-824 Type C 600VAirport Cable
Applications
These cables are designed for use in airport lighting and control circuits, suitable for installati... |
|
|
All Aluminum Alloy Conductor (AAAC) Cables |
All Aluminum Alloy Conductor (AAAC) Cables
Application
AAAC is mainly used as bare overhead transmission cable and as primary and secondary distrib... |
|
|
PE Insulated,Website:, LSZH Sheathed & Overall Screened, Armoured Instrumentation Cables (Single Pair)RE-2Y(St)HSWAH |
PE Insulated,Website:, LSZH Sheathed & Overall Screened, Armoured Instrumentation Cables (Single Pair)RE-2Y(St)HSWAH 90°C / 300VSTANDARDSBa... |
|
|
[FA-] MPYS, MPYCS, MPYCYS |
50V [FA-] MPYS,Website:, MPYCS, MPYCYSStandards:JISC 3410-1999IEC 60332-1IEC 60332-3 Cat.A(for FA-type)CABLE CONSTRUCTIONConductorMTinned annealed ... |
|
|
FAA L-824 Type B Unshielded 5kV Airport Cable |
FAA L-824 Type B Unshielded 5kV Airport Cable
Applications
These cables are used for interconnecting the transformers and the current regulator of ... |
Все товары поставщика