Fire Resistant Single Core 300-500V
Fire resistant cable single core 300 500v wirefeatures Mica tape twisted with copper conductor, the cable refers as Cu/MicaXLPE(PVC)/LSZH 300/500V to basic standard BS7211. The function of mica is to prevent burning when cables catching fire. The cable can maintain the integrity of the electric circuit and continue to work for a period of time when exposed to fire. The sheath is compound material LSFH low smoking free holagen which has little smoking and no toxic gas emission which reduces the damage to the people and equipment. These cables we supplied are twisted two layers of mica tape with 80% overlap rate which achieves a good performance of fire resistance.
Fire Resistant Single Core 300-500VCableParameter
Nominal Cross Section Area |
Nominal Insulation Thickness |
Nominal Sheath Thickness |
Without Earth Conductor |
||
mm² |
mm |
mm |
Nominal Overall Diameter |
||
mm |
|||||
7/0.53 |
29 |
||||
7/0.67 |
40 |
||||
4 |
7/0.85 |
55 |
Description of Fire Resistant Single Core 300-500V
Rated voltage: 300/500V
Basic standard: BS 7211
Conductor: bare annealed copper wire, stranded wire to IEC(EN) 60228 class 2
Fire lyer: Mica glass tape
Insulation: PVC (XLPE)
Sheath: LSZH compound to BS 7655-6.1
Operating temperature range (fixed state): -30°C – +90°C
Operating temperature range (mobile state): -20°C – +50°C
Min bending radius: 6 time of Overall Diameter
Insulation resistance: 20 MΩ x km (at 20°C)
Short circuit temperature: 250°C
Circuit Integrity |
IEC 60331-21; BS 6387 CWZ; DIN VDE 0472-814(FE180); |
CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3); |
|
NF C32-070-2.3(CR1) |
|
Flame Retardance (Single Vertical Wire Test) |
EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; |
VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); |
|
CEI 20-35/1-2; EN 50265-2-1*; DIN VDE * |
|
Reduced Fire Propagation (Vertically-mounted bundled wires |
EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30- |
004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE |
|
Halogen Free |
IEC 60754-1; EN 50267-2-1; DIN VDE ; |
CEI 20-37/2-1 ; BS 6425-1* |
|
No Corrosive Gas Emission |
IEC 60754-2; EN 50267-2-2; DIN VDE ; |
CEI 20-37/2-2 ; BS 6425-2* |
|
Minimum Smoke Emission |
IEC 61034-1&2; EN 61034 -1&2; DIN VDE &2; |
CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* |
|
No Toxic gases |
NES 02-713; NF C 20-454 |
Application Of Fire Resistant Single Core 300-500V
The cables are designed for facilities where keeping and maintaining integrity of the electrical circuit is critical in power supply system.
The cables are widely used in underground tunnels, emergency lightings, fire alarm systems, control and power circuits, power stations, lifts, escalators, and high-rise buildings.
As a reliable electric cable factory, we can offer sorts of xlpe insulated cablefor sale, if you are interested, please contact us.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
6mm Orange Circular Cable 4 Core+ Earth 0.6-1kv | 6mm 4 core and earth cableare widely used in Australia and New Zealand market following the standard of AS/NZS 5000.1. It is referred to as orange ... | |
CU/PVC H07V-U | CU/PVC H07V U cablefeatures a plain annealed solid conductor class 1 with PVC insulation. H07V-U cable is also known as building wire or electric w... | |
BS 5467 | Steel Wire Armoured XLPE Insulated Power Steel wire armoured power cable are also know as SWA armoured cable or armoured cable. Jenuincable supp... | |
6241B LSZH Single Cores +Earth Cable | As a China electric wire manufacturerand control cablesupplier with over 20 years of knowledge in the cables industry, we supply reliable cables wo... | |
4 Cores Power Cable (XLPE Insulated) | XLPE electrical wire 4 corepower cables are normally used in power transmission and distribution systems. The power cable 4 coreXLPE cable is refer... |