12v Smps
Features: High efficiency,Website:, high reliability and low cost Switch input voltage range choice 100% full load and machine test Protection characteristics: short circuit/overloadAir cooling Working frequency 37 KHz Two years warranty Size:159*98*38mm(L*W*H)modelS-60-5S-60-12S-60-15S-60-24S-60-48outputDc output voltage5V12V15V24V48VOutput voltage tolerance±2%±1%±1%±1%±1%Rated output current12A5A4A2.5A1.3AOutput current range0-12A0-5A0-4A0-2.5A0-1.3AOutput power60W60W60W60W62.4WRipple and the noise120mVp-p120mVp-p150mVp-p150mVp-p200mVp-pDc voltage adjustable scope+10, -5%±10%±10%±10%±10%Start, rise, keep time800ms,50ms,10ms/115VAC 300ms,50ms,80ms/230VACinputInput voltage range90 ~132 VAC / 180-264VAC by switch 47~63 Hz;120~370VDCExchange input current2A/115 V 1A/ 230 Vefficiency73%76%77%79%79%Impulse currentCold start current 30A/115VAC 60A/230VACLeakage current<3.5 mA/240VACProtection characteristicsOverload protection115%~165%Protection way: current limiting, automatic recoveryOver-voltage protection115%~135%Protection way: hiccups, auto recovery modeenvironmentWorking temperature, humidity-10℃~+60℃;20%~90 %RHKeep temperature, humidity-20℃~+85℃;10%~95 %RHVibrate resistance10~500Hz,2G 10min./1 cycle time, 60 minutes, the axissecurityCompression sex3: KVAC between input and output and input and output KVAC:1.5 to 0.5: KVACInsulation resistanceBetween the input and output, the input and output, and ground:100M Ohms/500VDCstandardSafety standardsAccord with UL1012, UL1950,TUV EN60950EMC standardsAccord with EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024otherweight0.5Kgpackaging30pcs/15.8Kg/0.99CUFTnote1.All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25 ℃ conditions measuring income value.2. Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement.3. Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate.4. The power to consider as a device installed in final equipment, this equipment must be to make sure it’s EMC index.5. Specific output current see output drop forehead curve
Другие товары поставщика
|
|
Specifications: 1.CE ROHS approved 2.AC85-264V input 3.2 years warranty Notice: a.We do have enough ability to produce your customized order b.Samp... |
|
|
Features:-vice rated voltage mode power supplyInternational general had full scopeHad small volume, light weight, high efficiencyCharacteristics: s... |
|
|
Specifications:1.CE ROHS approved 2.88~132VAC/176~264VAC CHOOSE BY SWITCH 3.85% efficiency 4.2 years warranty Notice:a.We do have enough ability to... |
|
|
Features:High efficiency, high reliability and low costSwitch input voltage range choiceProtection characteristics: short circuit/overload100% full... |
|
|
Features:1 and 0 had input voltage rangeHad small volume, light weight, high efficiencyCharacteristics: short circuit protection miscalculates/over... |
Все товары поставщика
Похожие товары