PCB Use Modular Meter Toroidal High Frequency Current Transformer
1.Electric strength: not less than 4kV/1mA/1min
Operating temperature: -40 to +85 Degrees Celsius
Relative humidity: less than or equal to 95% (25 Degrees Celsius)
Altitude: less than or equal to 10000m
High precision suitable for kWh meter class 0.2, class 0.5, class 1.0
Typical phase shift is at 1-10', additional compensation is not needed
Reliable and stable performance at different temperature conditions
Quick connection to PCB available on request
RoHS Directive-compliant is available on request
2.Primary current: 1A
Imax: 10A
Accuracy class: 0.1%
Turns ratio: 1: 1000
Frequency: 50-60 HZ
Load resistance: 10 Ohm
Withstanding volt: 4000V/1min
Ambient temp: -40-+70 Degrees Celsius
Storage temp: -40-+80 Degrees Celsius
Encapsulate: epoxy
Dielectric strength: not less than 4kV/1mA/1min.
Operating temperature: -40 to +85 Degrees Celsius
Relative humidity: less than or equal to 95% (25 Degrees Celsius)
Typical phase shift is at 1-10’, additional compensation is not needed.
Very reliable and stable performance at different temperature conditions
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Three Phase Power Meter Use 1:2000 Current Transformer | 1.Regular spec: 10 (100)A/4mA Other spec can be request Dielectric strength: not less than 4kV/1mA/1min Insulation resistance: >500M Ohm (500V D... | |
| Environmental Protection Material Reliable Performance Power Meter Use Current Sensor | Regular spec: Primary current: 10A Imax: 100A Accuracy class: 0.1% Frequency: 50Hz-60Hz Dielectric withstanding volt (Hi-pot): 4KVrms Ambient temp:... | |
| Three-Phase Fire retardancy Fully Enclosed Case Current Transformer | Regular spec: Primary current: 5A Imax: 60A Turns ratio: 1:2500 Accuracy class (%): 0.1% Load resistance: 20 Ohm Frequency: 50HZ-60HZ Dielectric Wi... | |
| Delicate Appearance Reliable Performance Epoxy Sealing Current Transformer | Regular spec: 1 (10)A/5mA other spec also can be requested Housing material: anti-burning ABS Encapsulation: epoxy resin Ambient temperature: -40 D... | |
| Three Phase Imax 40A Kwh meter Use Current Sensor | Regular spec: Primary current: 10A Imax: 40A Accuracy class (%): 0.1 Load resistance: 6.25 Ohm Frequency: 50HZ-60HZ Dielectric Withstanding Volt(Hi... |
Похожие товары
| China factory Transformer bushing BRDW-126/630-3 for power station | Продавец: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD | "China factory Transformer bushing BRDW-126/630-3 for power station YOYIK is a research and devel... | |
| TOROIDAL TRANSFORMER | Продавец: Yu Yang Magnetic Co., LTD | Seamless toroidal core (ferrite/powdered iron) minimizes core loss (<1.1W/kg) and achieves >... | |
| ACREL AID150 ALARM AND DISPLAY DEVICE | Продавец: Jiangsu Acrel Electrical Manufacturing Co., LTD. | The AID150 insulation monitoring device schneideris designed for visual and audible indication of... | |
| ACREL ANSVG STATIC VAR GENERATOR | Продавец: Jiangsu Acrel Electrical Manufacturing Co., LTD. | ANSVG series of reactive power and harmonic hybrid compensation devices are connected in parallel... | |
| The Working Principle of Active Power Filter | Продавец: Jiangsu Acrel Electrical Manufacturing Co., LTD. | Active power filter is a new type of power electronic device used to dynamically suppress harmoni... |