oil-immersed power transformers

The calorific base of transformer = no load loss + load loss.

No-load loss: when the transformer secondary winding is open and the primary winding applies the rated voltage of the rated frequency sinusoidal waveform, the active power consumed is called no-load loss.

Load loss: variable loss. It's proportional to the square of the current going through it. Load loss is the load loss at rated current and reference temperature. To expand, the so-called rated current refers to the primary side tapping position must be the main tapping, not the rated current of other tapping. For the reference temperature, it depends on the heat resistance grade of the insulation material of the transformer. For oil-immersed transformers, no matter they are self-cooled, air-cooled or strongly oil-cooled, they are all a-class insulation materials, and their reference temperature is specified according to the traditional concept, which is 75℃.

As atransformer manufacturer China ,ourcompany mainly produces:,, box-type substation, high and low voltage switchgear assembly and a variety of special-type transformers.



Отправить запрос, связаться с поставщиком

Кому: Baoding Zhongyi Electrical Material Manufacturing Co.,Ltd.
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

ZS Series Rectifier Transformer,oil immersed power transformer,high quality oil transformer,oil immersed power thransformer
ZS Series Rectifier Transformer,oil immersed power transformer,high quality oil transformer,oil immersed power thransformer ZS Series Rectifier Transformer,oil immersed power transformer,high quality oil transformer,oil immersed power thransformer Oil Immersed Transforme...
How to see the oil position of oil-immersed transformer?
How to see the oil position of oil-immersed transformer? oil-immersed transformeroil level gage to 30 °, + 20 ° and + 40 °, respectively is refers to the oil-immersed transformer at ambi...
What is the short circuit impedance of transformer?
What is the short circuit impedance of transformer? What is the short circuit impedance of transformer? Do you know what the short circuit impedance of transformer is? Transformer such as the, it i...
power oill transformer
power oill transformer distribution transformer The products implement the National Standard GB1094-2013 Power Transformer and GB / T6451-2015 Three-phase Oil-immersed Po...
Transformer Energy Saving is More and More Popularized
Transformer Energy Saving is More and More Popularized Transformers such asThree Phase Transformeralso have great developments and changes in the development experience, and the process of transformer ...
Все товары поставщика

Похожие товары

S11-M Power Transformer
S11-M Power Transformer Продавец: Bokong Electric Co., Ltd S11-M Product Description S11-M a new generation of low noise and low loss transformer devel...
Compact Transformer
Compact Transformer Продавец: Shaanxi Hanzhong Transformer Co., ltd As a leading compact transformer substationmanufacturer and box type substation supplier, SEC com...
Combined Pad Mounted Substation
Combined Pad Mounted Substation Продавец: Shaanxi Hanzhong Transformer Co., ltd Combined Pad Mounted Substation The ZBG series America Housing Type Transformer are researched a...
Amorphous Alloy Dry Type Transformer
Amorphous Alloy Dry Type Transformer Продавец: Shaanxi Hanzhong Transformer Co., ltd SCBH15eres amorphous alloy dry type transformerpertorms well not only for its excellent propertie...
35KV Power Transformer
35KV Power Transformer Продавец: Shaanxi Hanzhong Transformer Co., ltd This 35 KV transformerhas the characteristics of high efficiency and low loss, can save a lot of ...