.

600/1000V LSZH Sheathed, Armoured (2-4cores)

600/1000V LSZH Sheathed,Website:, Armoured ((2-4cores) Application:This range of screened cables drastically reduce interferences from electrical noise, especially in Variable Speed Drive (VSD) applications and are manufactured with fixed conductors.Standard:Basic design to IEC 60502-1; BS 6724FIRE PERFORMANCEFlame Retardance (Single Vertical Wire Test)EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE *Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE Halogen FreeIEC 60754-1; EN 50267-2-1; DIN VDE ; CEI 20-37/2-1 ; BS 6425-1*No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2; DIN VDE ; CEI 20-37/2-2 ; BS 6425-2*minimum Smoke EmissionIEC 61034-1&2; EN 61034 -1&2; DIN VDE &2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*No Toxic gasesNES 02-713; NF C 20-454Note: Asterisk * denotes superseded standard.VOLTAGE RATING 600/1000VCABLE CONSTRUCTION Conductor: Plain annealed copper wire, stranded according to IEC(EN) 60228 class 2.Insulation: Extruded cross-linked XLPE compound. Inner Sheath(optional): LSZH Compound Armouring(optional): Galvanized Steel WireOuter Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.)COLOUR CODE Insulation colour as per bs7671with earth conductorwithout earth conductor2Cores-Brown,Blue3CoresYellow/Green,Brown,BlueBrown,Gray,Black4CoresYellow/Green,Brown,Gray,BlackBrown,Gray,Black,Blue5CoresYellow/Green,Brown,Gray,Black,BlueBrown,Gray,Black,Blue,Blackabove 5 CoresYellow/Green,Black NumberedBlack Numberedsheath colour: BlackPhysical AND THERMAL PROPERTIESTemperature range during operation: Max.90°C250°C in short-circuit for 5s max. Minimum bending radius: 8 x Overall Diameter (unarmoured cable) 10 x Overall Diameter (armoured cable)CONSTRUCTION PARAMETERSConductorNo. of Core X Cross SectionNo./ Nominal Diameter Of StrandsNominal Insulation ThicknessUnarmouredArmouredNominal Overall DiameterApprox. WeightDiameter Under ArmourArmour Wire DiameterNominal Overall DiameterApprox. Weightmm²No./mmmmmmkg/kmmmmmmmkg/km2x1.57/0.530.710.01268.50.913.93502x2.57/0.670.710.81589.30.914.74002x47/0.850.711.920510.40.915.84752x67/1.040.713.026411.50.916.95602x107/1.350.714.937813.41.2519.58102x167/1.700.717.053415.51.2521.69802x257/2.140.920.465018.91.625.714102x357/2.520.922.788021.21.628.019303x1.57/0.530.710.51459.00.914.43903x2.57/0.670.711.41859.90.915.34503x47/0.850.712.524711.00.916.45403x67/1.040.713.832311.61.2517.77453x107/1.350.715.847414.31.2520.49503x167/1.700.718.068216.51.2523.012503x257/2.140.921.791020.21.627.018403x357/2.520.924.0118022.41.629.220503x50(S)19/1.781.025.5160024.21.631.225903x70(S)19/2.141.129.0224028.22.036.235603x95(S)19/2.521.133.5305031.72.040.145903x120(S)37/2.031.237.5380036.02.044.658103x150(S)37/2.251.440.5464039.52.553.569203x185(S)37/2.521.645.0587043.32.553.583403x240(S)61/2.251.750.5767048.42.559.0104503x300(S)61/2.521.857.0946054.42.565.4127003x400(S)61/2.852.063.01194557.82.570.0153264x1.57/0.530.711.316910.00.915.44304x2.57/0.670.712.322010.80.916.25054x47/0.850.713.629712.10.917.57104x67/1.040.715.039213.51.2519.68554x107/1.350.717.258515.71.2521.811204x167/1.700.719.785118.21.625.016004x257/2.140.923.9120022.41.629.221604x35(S)7/2.520.925.0160024.41.631.425604x50(S)19/1.781.028.0220028.01.635.231804x70(S)19/2.141.132.0305032.22.040.644904x95(S)19/2.521.137.0407036.02.044.654254x120(S)37/2.031.242.0591538.02.550.075504x150(S)37/2.251.446.0635042.82.553.085554x185(S)37/2.521.650.0789048.42.559.0105604x240(S)61/2.251.757.01040055.02.566.0131804x300(S)61/2.521.863.01281059.62.571.0161004x400(S)61/2.852.071.01586966.13.1579.4207154x500(S)61/3.202.278.02030074.63.1588.525347(S) - Sectoral Stranded ConductorsElectrical PROPERTIESConductor Operating Temperature : 90°CAmbient Temperature : 30°CUnarmoured Current-Carrying Capacities (Amp)Conductor cross- sectional areaReference method 4 (enclosed in conduit in thermally insulating wall etc)Reference method 3 (enclosed in conduit on a wall or in trunking etc)Reference method 1 (clipped direct)Reference method 11 (on a perforated cable tray, horizontal or vertical)Reference method 12 (free air)Horizontal flat spacedVertical flat spacedTrefoil2 cables, single- phase a.c. or d.c.3 or 4 cables, 3-phase a.c.2 cables, single- phase a.c. or d.c3 or 4 cables, 3-phase a.c.2 cables, single- phase a.c. or d.c. flat and touching3 or 4 cables, 3-phase a.c. flat and touching or trefoil2 cables, single- phase a.c. or d.c. or flat and touching3 or 4 cables, 3-phase a.c. flat and touching or trefoil2 cables, single- phase a.c. or d.c. or 3 c ables three phase2 cables, single- phase a.c. or d.c. or 3 cables three phase3 cables, trefoil 3-phase a.c.mm²AAAAAAAAAAA1..Voltage Drop (Per Amp Per Meter)Size of conductor2 cables d.c.2 cables, single-phase a.c.3 or 4 cables, 3-phase a.c.Ref. Methods 3 and 4 (enclosed in conduit etc, in or on a wall)Ref. Methods 1 and 11 (clipped direct or on trays touching)Ref. Methods 3 and 4 (enclosed in conduit etc, in or on a wall)Ref. Methods 1, 11 and 12 (in trefoil)Ref. Methods 1 and 11(Flat and touching)1234567mm²mV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/m1...87.96.86.86.86.8104.74.74.7444162.92.92.92.52.52.5rxzrxzrxzrxzrxz251.851.850.311.901.850.1901.851.600.271.651.6000.1651.6001.6000.1901.600351.351.350.291.351.350.1801.351.150.251.150.1501.551.501.1500.1801.150500.991.000.291.050.990.1801.000.870.250.900.8600.1550.8700.8600.1800.870700.680.700.280.750.680.1750.710.600.240.650.5900.1500.6100.5900.1750.620950.490.510.270.580.490.1700.520.440.230.500.4300.1450.4500.4300.1700.4601200.390.410.260.480.390.1650.430.350.230.420.3400.1400.3700.3400.1650.3801500.320.330.260.430.320.1650.360.290.230.370.2800.1400.3100.2800.1650.3201850.250.270.260.370.260.1650.300.230.230.320.2200.1400.2600.2200.1650.2802400.190.210.260.330.200.1600.250.1850.220.290.1700.1400.2200.1700.1650.2403000.1550.1750.250.310.160.1600.220.1500.220.270.1400.1400.1950.1350.1600.2104000.120.1400.250.290.130.1550.200.1250.220.250.1100.1350.1750.1100.1600.1955000.0930.1200.250.280.1050.1550.1850.1000.220.240.0900.1350.1600.0880.1600.180Armoured  Current-Carrying Capacities (Amp)Conductor crosssectional areaReference Method 1 (clipped direct)Reference Method 11 (on a perforated horizontal cable trayor Reference Method 13 [free air] )In single-way ductsLaid direct in groundone 2-core cable single phase a.c. or d.c.one 3-core or 4-core cable 3-phase a.c.one 2-core cable single phase a.c. or d.c.one 3-core or 4-core cable 3-phase a.c.one 2-core cable single phase a.c. or d.c.one 3-core or 4-core cable 3-phase a.c.one 2-core cable single phase a.c. or d.c.one 3-core or 4-core cable 3-phase a.c.123456789mm²AAAAAAAA1..Voltage Drop (Per Amp Per Meter)Conductor cross-sectional area2-core cable d.c.2 cables, single-phase a.c.3 or 4 cables, 3-phase a.c.2 cables, single- phase a.c.3 or 4 cables, 3-phase a.c.In ducts or in groundIn ducts or in ground123456mm²mV/A/mmV/A/mmV/A/mmV/A/mmV/A/m1.531.031.027.031.025.02.519.019.016.019.015.0412.012.010.012.09.767.97.96.87.96.5104.74.74.04.73.9162.92.92.52.92.6rxzrxz251.8501.3500.1601.9001.6000.1401.6501.9001.600351.3501.3500.1551.3501.1500.13501.1501.3501.200500.9800.9900.1551.0000.8600.1350.8701.0000.870700.6700.6700.1500.6900.5900.1300.6000.6900.610950.4900.5000.1500.5200.4300.1300.4500.5200.4501200.3900.40000.1450.4200.3400.1300.3700.4200.3601500.3100.3200.1450.3500.2800.1250.3000.3500.3001850.2500.2600.1450.2900.2200.1250.2600.2900.2502400.1950.2000.1400.2400.1750.1250.2100.2400.2103000.1550.1600.1400.2100.1400.1200.1850.2100.1904000.1200.1300.1400.1900.1150.1200.1650.1900.180


Отправить запрос, связаться с поставщиком

Кому: UNIVERSAL CABLES LIMITED
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

Type MP-GC Three-Conductor Mine Power Feeder Cable,Website:, PVC Jacket, 15kV ICEA S-75-381ApplicationsThese cables are designed for connections be...
Tight Buffer Optical Fiber Cables ApplicationThese optical fiber cables are designed to data transmission in ship and specially in cruise ship wher...
PE Insulated,Website:, LSZH Sheathed & Overall Screened, Armoured Instrumentation Cables (Single Pair)RE-2Y(St)HSWAH 90°C / 300VSTANDARDSBasic des...
Type 209 1.1 to 11KV to AS/NZS 1802ApplicationsType 209 series cable is mainly used as a flexible feeder to machinery,Website:, more suitable as a ...
300/500V XLPE Insulated,Website:, PVC Sheathed, Screened Power Cables  (2-4 Cores) CU/XLPE/OS/PVC 300/500V Class 2Application:The cables are mainly...
Все товары поставщика

Похожие товары

PMMA VR Lens For Google Cardboard
PMMA VR Lens For Google Cardboard Продавец: Jinhua Kaiyue Photoelectric Technology Co.,Ltd PMMA VR Lens For Google Cardboard,Double Convex Lens
PMMA Double Convex Lens
PMMA Double Convex Lens Продавец: Jinhua Kaiyue Photoelectric Technology Co.,Ltd PMMA Double Convex Lens,Double Convex Lens
6X21 PBinoculars
6X21 PBinoculars Продавец: Jinhua Kaiyue Photoelectric Technology Co.,Ltd 6X21 PBinoculars,Porro Prism Binoculars
Night Vision Binoculars
Night Vision Binoculars Продавец: Jinhua Kaiyue Photoelectric Technology Co.,Ltd Night Vision Binoculars,Porro Prism Binoculars
10X25 High Power Binoculars
10X25 High Power Binoculars Продавец: Jinhua Kaiyue Photoelectric Technology Co.,Ltd 10X25 High Power Binoculars,Binoculars & Scopes