.

300/500V SR Insulated LSZH Sheathed Fire Alarm Cables

300/500V SR Insulated & LSZH Sheathed Fire Alarm CablesFR200P 2GSH-U (PH30) (CU/SR/OS/LSZH 300/500V Class 1)FR200P 2GSH-R (PH30) (CU/SR/OS/LSZH 300/500V Class 2)Application:The cables are designed,Website:, manufactured and tested as data transmission cables for emergency services. These are primarily intended for for indoor instrumentation and control cabling, electrically noisy environments and fire alarm systems in office buildings when high frequency signal transmission has to be assured in the event of a fire.STANDARDS:Basic design to BS 7629-1FIRE PERFORMANCECircuit IntegrityIEC 60331-21; BS 6387 CWZ; DIN VDE 0472-814(FE180);BS 8434-1 (30mins); BS 5839-1 Clause 26 2d; CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3); NF C32-070-2.3(CR1)Circuit Integrity with mechanical shockEN 50200(PH30); CEI 20-36/4-0Circuit Integrity with mechanical shock & water sprayEN 50200 annex ESystem circuit integrityDIN 4102-12, E30 depending on lay systemFlame Retardance (Single VerticalWire Test)EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2;VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE *Reduced Fire Propagation(Vertically-mounted bundled wires& cable test)EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE Halogen FreeIEC 60754-1; EN 50267-2-1; DIN VDE ; CEI 20-37/2-1 ; BS 6425-1*No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2; DIN VDE ; CEI 20-37/2-2 ; BS 6425-2*Minimum Smoke EmissionIEC 61034-1&2; EN 61034 -1&2; DIN VDE &2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*No Toxic gasesNES 02-713; NF C 20-454Note: Asterisk * denotes superseded standard.CABLE CONSTRUCTION Conductors: Plain annealed copper wire, solid according to IEC(EN) 60228 class 1, stranded according to IEC(EN) 60228 class 2.Insulation: Fire resistant silicone rubber compound type EI2 as per BS 7655-1.1.Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimizecrosstalk. Two-pair cable had four cores laid in quad formation.Cabling: Pairs are cabled together in concentric layers with suitable non-hygroscopic fillers.Overall screen: Aluminum/polyester tape with tinned copper drain wire.Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZHcompound type SW2-SW4 as per BS 7655-2.6 can be offered.)COLOUR CODEInsulation Colour:Cables up to 6 pairs black-red / black-blue / red-blue / yellow-black /yellow-red / yellow-blueCables above 6 pairs all pairs black-red numbered on the wrapping tape.Sheath Colour: Colour red (other colours on request).Physical AND THERMAL PROPERTIESTemperature range during operation (fixed state): -30°C – +90°CTemperature range during installation (mobile state): -20°C – +50°CMinimum bending radius: 7.5 x Overall DiameterCONSTRUCTION PARAMETERSCable CodeNominal Insulation ThicknessNominal Sheath ThicknessNominal Overall DiameterApprox.Weightmm2mmmmmmkg/km1 Pairs1x2x1 FR200P 2GSH-R (PH30)0.60.97.4771x2x1.5 FR200P 2GSH-R (PH30)0.70.98,71002 Pairs2x2x1 FR200P 2GSH-R (PH30)0.61.010.61302x2x1.5 FR200P 2GSH-R (PH30)0.71.010.21883 Pairs3x2x1 FR200P 2GSH-R (PH30)0.61.111.21963x2x1.5 FR200P 2GSH-R (PH30)0.71.112.92235 Pairs5x2x1 FR200P 2GSH-R (PH30)0.61.213.72455x2x1.5 FR200P 2GSH-R (PH30)0.71.316.73466 Pairs6x2x1 FR200P 2GSH-R (PH30)0.61.214.83006x2x1.5 FR200P 2GSH-R (PH30)0.71.317.542610 Pairs10x2x1 FR200P 2GSH-R (PH30)0.61.418.937810x2x1.5 FR200P 2GSH-R (PH30)0.71.523.454115 Pairs15x2x1 FR200P 2GSH-R (PH30)0.61.523.256715x2x1.5 FR200P 2GSH-R (PH30)0.71.628.989220 Pairs20x2x1 FR200P 2GSH-R (PH30)0.61.626.283120x2x1.5 FR200P 2GSH-R (PH30)0.71.832.51182


Отправить запрос, связаться с поставщиком

Кому: UNIVERSAL CABLES LIMITED
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

Cat 5e F/UTP 24AWG IEC60092ApplicationThese Cat5e F/UTP cables are manufactured in accordance with IEC 61156-5 requirements,Website:, can support ...
NSSHCGEOEU 0.6/1kV Coal Cutter Cable (High Tensile Stress) VDE 0250 Part 812ApplicationsThese cables are used for the connection of mobile machines...
Type 210 1.1/1.1KV to AS/NZS 1802ApplicationsThese cables are mainly used for hand-held boring machines and drills.StandardsAS/NZS 1802:2003AS/NZS ...
German Standard Industrial Cables H05VVD3H6-FApplication and DescriptionThese cables are generally used in crews of,Website:, elevators for people ...
German Standard Industrial Cables NAYY-J/NAYY-OApplication and DescriptionNAYY is used in power plants industrial and switching installations,Websi...
Все товары поставщика

Похожие товары

PMMA VR Lens For Google Cardboard
PMMA VR Lens For Google Cardboard Продавец: Jinhua Kaiyue Photoelectric Technology Co.,Ltd PMMA VR Lens For Google Cardboard,Double Convex Lens
PMMA Double Convex Lens
PMMA Double Convex Lens Продавец: Jinhua Kaiyue Photoelectric Technology Co.,Ltd PMMA Double Convex Lens,Double Convex Lens
6X21 PBinoculars
6X21 PBinoculars Продавец: Jinhua Kaiyue Photoelectric Technology Co.,Ltd 6X21 PBinoculars,Porro Prism Binoculars
Night Vision Binoculars
Night Vision Binoculars Продавец: Jinhua Kaiyue Photoelectric Technology Co.,Ltd Night Vision Binoculars,Porro Prism Binoculars
10X25 High Power Binoculars
10X25 High Power Binoculars Продавец: Jinhua Kaiyue Photoelectric Technology Co.,Ltd 10X25 High Power Binoculars,Binoculars & Scopes