Polarimeter
Product advantages:
1. Better temperature control design, fast and accurate results Temperature is the external factor that has the greatest influence on the measurement of optical rotation. To eliminate its impact on measurement, the MCP series polarimeters are equipped with a fast, accurate and stable wraparound Peltier temperature control system. The temperature is precisely controlled in the range of 10 °C to 45 °C, and the built-in sensor is used in the optical rotation tube for accurate measurement, which is transmitted wirelessly to the instrument host.
2.FillingCheckTM video imaging technology enables you to observe the sample in the sample pool through real-time video during and after sample injection. Bubbles or streaks can easily be seen in the image more clearly than can be seen by the naked eye, and intervention can be made if necessary. The image is automatically saved along with the measurement results. As a result, traceable documentation of measurement conditions can be found even after many years.
3. Better user friendliness, traceability and data integrity Anton Paar polarimeters are designed with the user in mind. The built-in software is intuitive, fast, and easy to use. The system will guide you through the measurement and calibration step by step; Corrected readings are given in seconds. To avoid any human input errors, the instrument has a unique ToolMaster TM function. All parameters related to the sample pool and standard quartz tube are transmitted wirelessly to the instrument software via RFID.
4. For better collection and transfer of measurement results to external storage locations, the MCP series offers superior connectivity and data integrity.
Meet the standard:
The MCP series of polarimeters comply with national and international standards such as Pharmacopoeia, GMP, GLP, GAMP 5, OIML and 21 CFR Part 11. Its built-in microcomputer can store different data (e.g. measurement results, audit trail, inspection/calibration data) and can disable data storage mode according to USP 1058> requirements. In addition, the polarimeter can be operated remotely from an external PC. With the Anton Paar Pharmaceutical certification document, the new MCP polarimeter can be integrated into your workflow in a very short time. It saves time and money.
Technical parameters:
Temperature control range: 10 °C to 45 °C
Temperature control method: Wraparound Peltier system
Temperature sensor location: Built-in sensor in the optical rotation tube
Measurement speed: Corrected readings given in seconds
Data storage: Built-in microcomputer stores measurement results, audit trail, inspection/calibration data. Can disable storage per USP .
Compliance: Meets Pharmacopoeia, GMP, GLP, GAMP 5. OIML, 21 CFR Part 11. USP .
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Glow wire tester | F242 Glow-wire tester, By simulating the thermal stress caused by heat source or ignition source such as hot component or overload resistor in a sh... | |
| Photocatalysis Illumination Apparatus | Applicable standards: JIS r1702 / New ceramics - Antibacterial activity test and antibacterial effect of antibacterial processed products under li... | |
| Multi-Finger Scratch/Mar Tester | Standards Chrysler LP-463DD-18-01 Scratch and Mar Resistance of Automotive Plastics Chrysler PF-10938 Scratch and Mar - Resistance of Molded-In-C... | |
| New warm body dummy tester-QINSUN | Product Description In addition to heat dissipation to the surrounding environment through conduction, convection and radiation, the human body al... | |
| Gravel Resistant Impact Tester | Standards ASTM D3170: Coating resistance to gravel impingement. ISO 20567: Paints and varnishes – Resistance to stone chipping. SAE J400... |













