Building material monomer combustion tester
Get a quote:
Whats/App: +86 185 0176 3615
Web: qinsun-lab.com
Monomer building materials combustion equipment is used to determine the construction materials or products (not including floor materials and the EC resolution of 2000/147 / EC (it and pointed out that the products) in the monomer (SBI) combustion test fire response performance of the size of test device. The device USES the computer interface to control the test equipment directly, which greatly saves the manpower and material resources.
Standards:
GB 8624-2012: building materials and product combustion performance rating
GB/T 20284-2006: "single combustion test for building materials or products"
EN 13823:2002 :"building products fire response - single combustion test method for building products without paving materials"
ISO – Plastics—Smoke Generation, Part 2: Single-Chamber Test for Optical Density
ASTM E662-2014 – Standard Test Method for Specific Optical Density of Smoke Generated by Solid Materials
BS 476-6:1989 – Fire Tests on Building Materials: Method of Test for Fire Propagation
EN 13501-1:2007 – Fire Classification of Construction Products and Building Elements, Part 1: Reaction to Fire
Parameters:
| Item | Specification |
|---|---|
| Combustion laboratory size | 3000mm * 3000mm * 2800mm |
| Outline dimensions of smoke pipe in combustion chamber | 5200mm * 3000mm * 1800mm |
| Control box outline dimension | 800mm * 1200mm * 1500mm |
| Smoke extraction speed | 0.50m³/s ~ 0.65m³/s |
| Temperature measurement device | Imported K-type armored thermocouple, 3mm diameter |
| Temperature measurement precision | ±0.5℃ |
| Accuracy of pressure sensor | (Not specified) |
| Test time | 1560s; Time recording system accuracy: 0.1s |
| Oxygen analysis (paramagnetism) range | (0-25)% |
| Oxygen analysis response time | <12s |
| Oxygen analysis noise drift (within 30min) | ≤100 x 10⁻⁶ |
| Oxygen analysis data collection and output resolution | >100 x 10⁻⁶ |
| Carbon dioxide (IR) measurement range | (0-10)% |
| Carbon dioxide measurement linearity | >1% of full range |
| Carbon dioxide data collection and output resolution | >100 x 10⁻⁶ |
| Detector color standard accuracy | ±5% |
| Detector output linearity (transmittance) | <3% |
| Detector absolute penetration rate | <1% |
| Test environment temperature | (10 ~ 30)℃ |
| Control cabinet power supply voltage | AC 220V 50HZ |
| Maximum equipment power | 11.5KW |
| Alarm condition | Flue gas pipeline temperature >400℃ |
| Sample adjustment status temperature | (21-25)℃ |
| Sample adjustment status humidity | (45-55)% RH |
| Distance of test piece from opposite side | 2100mm |
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Automatic pH Tester | ASTM ISO Testing Machine | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The Fully Automatic pH Tester for Textiles and Leather Products is designed to aut... | |
| Rubber Low Temperature Brittleness Tester | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The Rubber Low Temperature Brittleness Tester determines the temperature at which ... | |
| Children\'s Product Comprehensive Force Tester | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Email: serving@qinsun-lab。com Applicable Standards GB/T 31701 - 2015. GB/T 6675 ... | |
| Blow-By Test Rig | ASTM ISO Testing Machine | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Test system for the characterisation of the oil content in blow-by gases at engine... | |
| large xenon lamp weathering and photoaging tester | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Email: serving@qinsun-lab。com Qinsun SUNTEST XXL+is a large xenon lamp weathering... |