Multi-Function Thermal Constants Analyzer
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Multi-Function Thermal Constants Analyzer is a versatile analytical instrument designed for accurate measurement of absolute thermal conductivity, thermal diffusivity, specific heat capacity, and thermal effusivity of solids, liquids, pastes, and powders. By integrating multiple transient measurement methods within a single platform, the system supports comprehensive thermal characterization across a wide range of materials and temperature conditions, making it suitable for both research and standardized testing applications.
Application
The Multi-Function Thermal Constants Analyzer is used for quantitative thermal property evaluation in various material forms and industries, including:
Polymers, composites, and construction materials
Liquids, phase-change materials, and coolants
Pastes, powders, and bulk solids
Soil, polymers, and anisotropic materials
Typical test samples include solid plates, bulk materials, liquids in containers, pastes, powders, and soil samples, depending on the selected measurement method.
Standards
The analyzer supports multiple internationally recognized test methods and standards, including:
(1) ISO 22007-2: Plastics — Determination of thermal conductivity and thermal diffusivity — Transient plane heat source method
(2) ISO 22007-7: Plastics — Determination of thermal conductivity and thermal diffusivity using transient plane heat source
(3) GB/T 32064: Transient plane heat source method for thermal conductivity and thermal diffusivity of building materials
(4) ASTM E3088: Standard test method for determination of thermal conductivity and thermal diffusivity using the transient plane source method
(5) ASTM D7896: Transient hot-wire method for thermal conductivity, thermal diffusivity, and volumetric heat capacity of liquids
(6) ASTM D5334: Transient line-source probe method
(7) ASTM D5930: Determination of thermal conductivity of plastics by transient line-source technique
(8) IEEE 442: Soil thermal resistivity measurement
Parameters
| Method | TPS | THW | MTPS | THS | TLS |
|---|---|---|---|---|---|
| Applicable Materials | Solids, pastes, powders | Liquids, phase-change materials | Solids, pastes, powders | Solid rectangular samples | Soil, pastes, polymers |
| Measurement Mode | 3D bulk, anisotropic, plate, thin film, 1D | Bulk | 3D bulk, anisotropic, plate, 1D | Bulk, anisotropic | Bulk |
| Thermal Conductivity (W/m·K) | 0.005–2000 | 0.01–2 | 0.03–500 | 0.01–2 | — |
| Thermal Diffusivity (mm²/s) | 0.01–1200 | Up to 0.5 | 0.01–300 | Up to 0.5 | — |
| Volumetric Heat Capacity (MJ/m³·K) | Up to 5 | Up to 5 | Up to 5 | Up to 5 | — |
| Thermal Effusivity (W·s½/m²·K) | 5–60000 | Not applicable | 20–40000 | Not applicable | — |
| Contact Thermal Resistance (m²·K/W) | Measured | Not applicable | Measured | Not applicable | Not applicable |
| Sample Thickness (mm)* | ≥0.01 | — | ≥0.1 | — | — |
| Test Time (s) | 0.25–2560 | 1 | 0.25–2560 | 0.25–2560 | 180 |
| Accuracy (Thermal Conductivity) | 3% | 2% | 5% | 5% | 5% |
| Repeatability (Thermal Conductivity) | 1% | 1% | 2% | 2% | 2% |
| Temperature Range (°C)** | 0 to 300 / up to 750 or 1000 | 10 to 200 | 0 to 100 / −50 to 200 | −75 to 300 | −40 to 100 |
| Sample Configuration | Symmetric / asymmetric | Insert type | Asymmetric (single-sided) | Symmetric / asymmetric | Insert type |
Features
Supports multiple transient methods within one integrated system
Measures absolute thermal conductivity, thermal diffusivity, specific heat, and thermal effusivity
Suitable for solids, liquids, pastes, powders, and soil samples
Wide thermal conductivity and temperature measurement ranges
Direct measurement of sensor–sample contact thermal resistance for improved accuracy
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Automotive interior material wash resistance testing machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application Primary applications: Assessing scratch resistance of automotive paint and cl... | |
| Toxicity index tester manufacturer | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Toxicity Index Tester is a specialized instrument designed for evaluating... | |
| Plastic Biodegradation Testing System,ISO 16929 Biodegradable Plastic Testing Instruments | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Plastic Biodegradation Testing System is a laboratory system used to evaluate the ultim... | |
| Oxygen Cannula Quality Control Testing Equipment Supplier | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com This device is used to test various performance characteristics of nasal cann... | |
| Intramedullary Nails Internal-fixation Pull-out Force Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard ASTM F543: Standard specification for metallic medical bone screws (dynamic loadi... |
Похожие товары
| MMA-120 Handheld Arc Welder | Продавец: 871183 | The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con... | |
| SHX Series Circulating Fluidized Bed Steam Boiler | Продавец: Hebei Genjux Boiler Co.,Ltd | Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi... | |
| YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler | Продавец: Hebei Genjux Boiler Co.,Ltd | Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ... | |
| DHL Series Coal-Fired Steam Boilers | Продавец: Hebei Genjux Boiler Co.,Ltd | Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b... | |
| SZL Series Biomass Steam Boiler | Продавец: Hebei Genjux Boiler Co.,Ltd | Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi... |