Multi-Function Thermal Conductivity Measurement Platform
Get a quote:
Web: qinsun-lab.com
Email:serving@qinsun-lab。com
Application
The Multi-Function Thermal Conductivity Measurement Platform is suitable for thermal property evaluation in research, quality control, and material development, including:
Polymers, composites, and building materials
Liquids and phase-change materials
Pastes, powders, and bulk solids
Soil and polymeric materials
Typical test samples include solid blocks and plates, liquid samples, powders, pastes, and soil specimens, depending on the selected sensor and test method.
Standards
The platform supports internationally recognized absolute measurement standards, including:
(1) ISO 22007-2: Plastics — Determination of thermal conductivity and thermal diffusivity — Transient plane heat source method
(2) ISO 22007-7: Plastics — Determination of thermal conductivity and thermal diffusivity using transient plane heat source
(3) GB/T 32064: Transient plane heat source method for thermal conductivity and thermal diffusivity of building materials
(4) ASTM E3088: Determination of thermal conductivity and thermal diffusivity using the transient plane source method
(5) ASTM D7896: Transient hot-wire method for thermal conductivity, thermal diffusivity, and volumetric heat capacity of liquids
(6) ASTM D5334: Transient line-source probe method
(7) ASTM D5930: Determination of thermal conductivity of plastics by transient line-source technique
Parameters
| Method | TPS | THW | MTPS | TLS |
|---|---|---|---|---|
| Applicable Materials | Solids, pastes, powders | Liquids, phase-change materials | Solids, pastes, powders | Soil, pastes, polymers |
| Measurement Module | 3D bulk, anisotropic, plate, thin film; general: specific heat | Bulk | 3D bulk, anisotropic, plate; 1D standard | Bulk |
| Thermal Conductivity (W/m·K) | 0.01–500 | 0.01–2 | 0.03–500 | 0.1–8 |
| Thermal Diffusivity (mm²/s) | 0.01–300 | Up to 0.5 | 0.01–300 | Not applicable |
| Volumetric Heat Capacity (MJ/m³·K) | Up to 5 | Up to 5 | Up to 5 | Not applicable |
| Thermal Effusivity (W·s½/m²·K) | 20–40000 | Not applicable | 20–40000 | Not applicable |
| Sample Size (mm | mL) | Ø10 or square | 20 mL | Ø25 or square |
| Sample Thickness (mm) | ≥0.05 | Not applicable | ≥0.1 | Probe length 100 |
| Maximum Sample Size | Unlimited | Unlimited | Unlimited | Unlimited |
| Test Time (s) | 2–160 | 1 | 2–160 | 180 |
| Accuracy (Thermal Conductivity) | 5% | 2% | 5% | 5% |
| Repeatability (Thermal Conductivity) | 2% | 1% | 2% | 2% |
| Temperature Range (°C) | 0–300 / −75–300 | −50–200 | 0–100 / −50–200 | −40–100 |
| Sample Configuration | Symmetric / asymmetric | Insert type | Asymmetric (single-sided) | Insert type |
| Supported Standards | ISO 22007-2. ISO 22007-7. GB/T 32064. ASTM E3088 | ASTM D7896 | ISO 22007-7 | ASTM D5334. ASTM D5930 |
Features
Absolute measurement methods with no calibration materials required
Multiple transient techniques integrated on a single platform
Direct measurement of thermal conductivity, thermal diffusivity, specific heat, and thermal effusivity
Suitable for solids, liquids, pastes, powders, and soil
Raw data–based calculation improves traceability and measurement reliability
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Nonwovens liquid loss tester | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The Nonwovens Liquid Loss Tester is a precision instrument designed to evaluate th... | |
| Cross Hatch Cutting and Adhesion Tester | ASTM ISO Testing Machine | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The Cross Hatch Cutting and Adhesion Testing provides a relative movement of the s... | |
| Dynamic footwear water penetration tester | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Application: Dynamic Footwear Water Resistance Tester is designed to determine th... | |
| Circular Locus Pilling Tester | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The instrument is used to test the pilling conditions ofwool fabric, chemical fibe... | |
| Four-Ball Tribometer(Value Engineered Tribometer) | Get a quote: Web: qinsun-lab.com Email:info@qinsun-lab。com The Four-Ball Tribometer is a high-precision laboratory instrument designed to evalua... |
Похожие товары
| PanEVAP & MVR system | Продавец: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | A multiple-effect evaporator is a device that efficiently uses steam heat to evaporate water. Wat... | |
| PanGAP wide gap welded plate heat exchanger | Продавец: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanGAP wide gap welded plate heat exchangerconsists of a welded plate pack with different channel... | |
| PanBloc welded plate heat exchanger | Продавец: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanBloc welded plate heat exchangeris compact and efficient, although fully welded, is totally ac... | |
| PanBox welded plate heat exchanger | Продавец: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanBox welded plate heat exchangerconsists of a laser welded plate pack with optimized corrugated... | |
| PanPHE gasketed plate heat exchangers | Продавец: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanPHE gasketed plate heat exchangersare designed with easy access for regular servicing and for ... |