Air Conditioner Thermal Comfort Environment Test Chamber
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Application
HVAC and Thermal Comfort Research: Study human thermal comfort and conduct experimental teaching in controlled climate environments.
Textile and Apparel Testing: Test and optimize textile and garment performance under varying temperature and humidity conditions to ensure comfort, durability, and compliance with standards.
Electronics and Components Reliability: Perform high/low temperature, constant and cyclic, and humid-heat testing for electronics, components, and materials to evaluate environmental reliability.
Automotive Battery Testing: Simulate different environmental conditions to verify safety, reliability, and performance of power batteries.
Pharmaceutical and Life Sciences: Evaluate drug stability, degradation, and efficacy under controlled temperature and humidity conditions.
Medical and Sports Science: Measure human oxygen consumption, CO₂ production, and energy metabolism; customized chambers can serve as human metabolism test units for medical and sports research.
Standards
Internal compliance with laboratory safety and electrical standards.
Temperature and humidity control performance aligned with industrial environmental simulation requirements.
Customization may include air exchange compliance per client specifications.
Parameters
| No. | Item | Technical Specifications |
|---|---|---|
| 1 | Chamber Dimensions | External: 4 m (L) × 4 m (W) × 3.2 m (H) Internal: 3.8 m (L) × 3.8 m (W) × 2.6 m (H) Standard insulated door: 0.8 m × 2.0 m with double-glass observation window Internal lighting: 1 daylight lamp; power outlet: 2.5 kW Digital display panel for temperature and humidity readings Optional window installation available upon request |
| 2 | Temperature Range | 10–43°C ±0.5°C adjustable |
| 3 | Humidity Range | 35–90% ±5% adjustable |
| 4 | Air Change Rate | 4–12 ACH; optional single-pass fresh air supply available (additional installation required) |
| 5 | Electrical Control System | Centralized control panel; Supply: AC 380V/50Hz, max power ≤15 kW; Equipped with short-circuit and over-temperature protection |
| 6 | Working Environment | Standard laboratory conditions |
| 7 | Other Requirements | Refrigeration unit piping and electrical lines default 5 m; site preparation including leveling, wall openings, rain shelter, water supply, drainage, and main power line to control box to be provided by user; chamber panels: 100 mm PU double-color steel |
| 8 | Special Notes | Default specifications are factory standards; custom requirements exceeding these parameters require additional consultation and pricing |
Accessories
Digital display panel for temperature and humidity monitoring.
Standard insulated chamber door with double-glass observation window.
Internal lighting system (daylight lamp).
Optional fresh air supply system.
Test Procedures
Chamber Preparation: Verify power, water, and drainage connections; ensure refrigeration system is operational (~10 min).
Set Environmental Conditions: Program desired temperature (10–43°C) and humidity (35–90%) on control panel or software interface (~5 min).
Load Samples/Subjects: Place equipment, test materials, or participants inside the chamber; ensure proper positioning and spacing (~10 min).
Run Test: Start test program; monitor chamber conditions in real-time via display panel or software interface; adjust parameters if needed (~duration dependent on experiment).
Data Recording and Export: Temperature, humidity, and other environmental data can be recorded, saved, and exported for analysis (~5 min).
Completion and Retrieval: End program, allow conditions to return to safe levels, and remove samples or subjects safely (~10 min).
Maintenance Information
Regularly clean observation windows, internal lighting, and control panels.
Inspect refrigeration unit, piping, and electrical connections for leaks, damage, or wear.
Verify sensor calibration periodically to ensure accurate temperature and humidity readings.
Maintain chamber in a clean, dust-free, and temperature-stable environment.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Laboratory Particle Strength Measurement Machine ISO Standard | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards (1) ASTM D4179 — Standard Test Method for Single-Pellet Pres... | |
| Torque - to - Failure Tester for Metal Bone - connecting Screws | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard YY/T 0662-2008(Chinese standard for orthopedic implant testing) ISO 5832-1(Metal... | |
| PV Hail Impact Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The PV Hail Impact Tester is a precision instrument designed to evaluate the mechanical res... | |
| Aluminum Foil Pinhole Detector for lab use | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards - YBB00152002 - 2015 Pharmaceutical Aluminum Foil - GB/T 3198 - 2010 Aluminum a... | |
| UV curing light box | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard ISO 10977: Adheres to industrial standards for UV curing of adhesives and coating... |
Похожие товары
| MMA-120 Handheld Arc Welder | Продавец: 871183 | The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con... | |
| SHX Series Circulating Fluidized Bed Steam Boiler | Продавец: Hebei Genjux Boiler Co.,Ltd | Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi... | |
| YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler | Продавец: Hebei Genjux Boiler Co.,Ltd | Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ... | |
| DHL Series Coal-Fired Steam Boilers | Продавец: Hebei Genjux Boiler Co.,Ltd | Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b... | |
| SZL Series Biomass Steam Boiler | Продавец: Hebei Genjux Boiler Co.,Ltd | Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi... |













