ISO/ASTM Compliant FTIR Smoke Toxicity Test Apparatus
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Standards
The system supports smoke toxicity testing and gas analysis in accordance with the following international and industry standards:
(1) DIN 5510-2 – Fire Behaviour and Smoke Toxicity of Materials Used in Railway Vehicles
(2) ISO 19702 – Guidelines for Sampling and Analysis of Toxic Gases and Vapours in Fire Effluents Using Fourier Transform Infrared (FTIR) Spectroscopy
(3) ISO 5659-2 – Plastics — Smoke Generation — Part 2: Determination of Optical Density by a Single-Chamber Test
(4) EN 45545-2 – Railway Applications — Fire Protection on Railway Vehicles — Requirements for Fire Behaviour of Materials and Components
Parameters
| Item | Specification |
|---|---|
| Quantifiable Gas Species | More than 300 compounds |
| Spectral Range | 4500–800 cm⁻¹ |
| Spectral Resolution | Better than 1 cm⁻¹ |
| Gas Analysis System | Multi-pass gas cell with 5 m optical path |
| Working Pressure | 0–15 bar |
| Maximum Working Temperature | Up to 191 °C |
| Dedicated Filter | Filters dust particles ≥ 2 μm |
| System Integration | 19-inch standard industrial chassis |
Features
Wide application flexibility, enabling gas measurements under different pressure and temperature conditions through appropriate accessories.
Optimized high-throughput optical design of the gas cell allows quantitative analysis of mixed gases even at concentrations as low as the ppb level.
No gas calibration is required; the system software automatically retrieves target gas concentrations using nonlinear fitting algorithms.
Effects caused by interfering gases and temperature variations are automatically compensated, ensuring accurate real-time qualitative and quantitative results.
Optical system employs a thermoelectrically cooled detector, CenterGlow™ infrared light source for stable high emission, and a RockSolid interferometer to ensure permanent optical alignment.
Equipped with dedicated sampling probes for gas extraction from pipelines or sealed chambers.
Independent and complete gas analysis software package with an intuitive graphical user interface.
Enables fast, continuous, and fully automated gas identification and quantification without requiring specialized user expertise.
Accessories
(1) Multi-pass gas cell with 5 m optical path
(2) Dedicated gas sampling probe
(3) Dust filtration unit (≥ 2 μm)
(4) Integrated interferometer module
(5) Infrared light source and detector assembly
(6) Industrial control and analysis software package
(7) 19-inch industrial chassis and mounting components
Test Procedures
System Preparation
Install the FTIR system in a stable environment and ensure the gas cell, filter unit, and sampling probe are correctly connected.
Sampling Setup
Insert the dedicated sampling probe into the pipeline, test chamber, or smoke outlet where gas collection is required.
Software Configuration
Launch the gas analysis software and select the corresponding measurement or monitoring mode according to the test objective.
Gas Measurement
Gas samples are continuously introduced into the multi-pass gas cell, where infrared spectra are collected and processed in real time.
Data Analysis and Output
The software automatically performs qualitative identification and quantitative analysis of gas components and displays real-time concentration results, which can be stored or exported for further evaluation.
Maintenance Information
Routine inspection of the gas sampling probe, filtration unit, and gas cell is recommended to ensure stable sampling and optical performance. Dust filters should be replaced periodically based on operating conditions. Optical components such as the interferometer and infrared source are designed for long-term stability and require minimal adjustment. Regular software updates and data backups are advised to maintain reliable system operation and data integrity.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| High Accuracy Scratch Resistance Tester KK-02 for Tribology Research | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ISO 19252 — Plastics — Determination of scratch resist... | |
| Universal Abrasion Resistance Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com TheUniversal Abrasion Resistance Testercan be used to flat grinding, mill grinding, edge gr... | |
| ISO 17707 footwear bending resistance and crack test equipment laboratory use | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications (1)Testing finished athletic shoes such as running shoes, baske... | |
| EN 1822-3 HEPA and ULPA filter testing System | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application (1) Small HEPA Filter Element Efficiency Testing: Verification of overall effi... | |
| Rail transit car wire abrasion testing machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Rail Transit Car Wire Abrasion Testing Machine is designed to evaluate the abrasion res... |