Equipment for Overcharge, Short Circuit, and Thermal Runaway
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Standards
The pressure vessel complies with the following standards:
(1) UL 9540A:2025 – Standard for Testing Thermal Runaway Fire Propagation in Battery Energy Storage Systems
(2) PV8450 – Battery Thermal Runaway Test Method
Parameters
| Item | Specification |
|---|---|
| Working Pressure | ≥ 3 MPa, equipped with safety valve for automatic pressure relief |
| Vessel Temperature Resistance | > 1200 °C |
| View Window | Diameter 5–25 cm |
| Thomas Sampling Pump | Adjustable manual exhaust, capable of achieving -90 kPa vacuum |
| Control Cabinet | Standard 19-inch touchscreen, metal frame |
| Environmental Configuration | External nitrogen achieves oxygen concentration <1% |
| Backup Gas Source | Nitrogen ≥ 99.99% purity |
| Power Supply | AC 220 V, 50/60 Hz, 10 A |
Features
Customizable Stainless Steel Vessel
Sealed chamber made of 304 stainless steel; test volume and dimensions can be tailored to specific applications.
Multi-Functional Interfaces
Flanged connection plates with specialized fittings allow for temperature, voltage, heating, and overcurrent connections.
Vacuum and Nitrogen Filling Capability
Achieves oxygen concentration below 1% to simulate inert test environments.
Weighing Platform Integration
Optional platform with load sensors enables mass loss monitoring during thermal events.
Safe and Easy Cell Handling
Swing door with locking screws ensures airtight seal; movable metal cell holder allows stable sample placement.
Pressure Monitoring
Customizable range via high-precision sensors to capture vessel internal pressure dynamics.
Multi-Channel Data Acquisition
12 temperature channels (expandable), 2 voltage channels for real-time battery voltage monitoring.
Gas Flow Control
Manual ball valves and solenoid valves protect sensors and prevent gas leakage.
Advanced Control Cabinet
19-inch touchscreen in a metal frame with electrostatic spray coating, high-temperature baking process for durability, easy cleaning, and aesthetic appearance.
Automated Data Monitoring
Siemens PLC and analog modules, integrated with LabVIEW software, monitor temperature, pressure, and oxygen concentration in real time, and store data for later analysis.
Report Generation
Test data can be exported as Excel, Word, or PDF files for documentation and further analysis.
Accessories
(1) Thomas sampling pump
(2) Safety valves and pressure sensors
(3) Temperature and voltage sensor interfaces
(4) Nitrogen filling system
(5) Weighing platform with load sensors
(6) Film heating interface
(7) Overcurrent protection interface
(8) Standard electrical control cabinet with touchscreen and PLC
Test Procedures
Cell Installation: Place battery cells in the vessel on the movable holder and lock the chamber door.
System Preparation: Connect external nitrogen supply and set oxygen concentration below 1% if required.
Parameter Setup: Configure temperature, pressure, and voltage monitoring channels via the touchscreen.
Initiate Test: Activate PLC control system to begin thermal runaway simulation.
Data Monitoring: Record pressure, temperature, oxygen levels, and cell voltage in real time; optional mass loss measurement.
Data Storage and Report Generation: Export all test data and results in Excel, Word, or PDF format.
Post-Test Procedures: Vent the vessel, safely remove battery cells, and inspect the chamber and sensors for next use.
Maintenance Information
Regularly inspect all valves, fittings, and flanged connections for tightness and integrity.
Calibrate temperature and pressure sensors periodically to ensure accurate measurements.
Clean the interior vessel and viewing window to maintain visibility and prevent contamination.
Verify nitrogen supply system and vacuum pump operation before each test.
Backup all test data and system logs to secure storage for traceability and compliance verification.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Strength Tester for Lead - end of Photovoltaic Modules | The Strength Tester for Lead-End of Photovoltaic Modules is designed to evaluate the mechanical integrity and tensile strength of PV module connect... | |
| Bone Screw Pull-out Tester | Standard YY/T 1504. ASTM F543: standard specifies a test method for measuring the axial force required to extract or fail a metallic bone screw f... | |
| Test for Flammability of Materials ,AS1530.2,Fire reaction test apparatus | Whats/App: +86 156 1874 6768 Web: standard-groups.com Introduction Thistester is developed base on thestandard AS1530.2. test for flammability o... | |
| Helmet Wearing Height Testing Machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com Main Purposes Measure the wearing height of helmets to ensure the accuracy and safety of h... | |
| Stain resistance tester for architectural coatings | Product Introduction The interior wall coating in architectural coatings is often polluted by some pollution from daily necessities, people often ... |
Похожие товары
| ISO 29463 HEPA/ULPA filter performance testing System | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system supports and compli... | |
| High-Precision ISO 16890 Filter Media Test Rig for R&D and QC | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system can execute and com... | |
| Mobile Floor Scrubber Aging Life Tester IEC 60312 | Продавец: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com TheMobile Floor Scrubber Aging L... | |
| ISO 12103 Cleanable Filter Media Test System | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system complies with: (1)... | |
| Robotic Vacuum Cleaners Edge-Following Tester | Продавец: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com TheEdge-Following Test Equipment... |