Adiabatic Calorimeter for Batteries
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Battery adiabatic calorimeters play a crucial role in battery research and development, providing essential thermodynamic data for safety assessment, performance optimization, energy efficiency analysis, and lifespan prediction.
Application
Battery adiabatic calorimeters are widely used in the research, testing, and safety evaluation of batteries and battery packs. They can provide thermal characteristic data of batteries during charging and discharging processes, offering crucial support for battery design and optimization. These instruments play a key role in battery thermal safety assessment, thermal management system performance evaluation, and material thermal safety testing.
Standards
(1)GB/T 36276 - 2023:Lithium-ion Batteries for Electric Power Energy Storage
(2)UL 9540A:Test Method for Evaluating Thermal Runaway Fire Propagation in Battery Energy Storage Systems
(3)ASTM E1981 - 98(2012):Standard Test Method for Thermal Stability of Chemicals by Differential Scanning Calorimetry (DSC)
(4)SN/T 3078.1 - 2012:Guidelines for the Evaluation of Thermal Stability of Chemicals - Part 1: Accelerated Calorimetry Method
(5)USABC SAND99 - 0497:This is a specific test protocol document from the United States Advanced Battery Consortium (USABC), and it doesn't have a widely recognized single "English name" in the same sense as formal standards. It could be referred to as "USABC Thermal Stability Test Protocol SAND99 - 0497"
(6)SAE J2464 - R2009:Electric and Hybrid Electric Vehicle Rechargeable Energy Storage System (RESS) Safety and Abuse Testing
(7)Freedom CAR SAND 2005 - 3123:Similar to USABC SAND99 - 0497. it is a specific technical document from the Freedom CAR program. It could be called "Freedom CAR Thermal Stability Test Document SAND 2005 - 3123"
(8)UL 1973:Batteries for Use In Stationary and Vehicle Auxiliary Power Applications
(9)GB 38031 - 2020:Safety Requirements for Power Batteries of Electric Vehicles
Features
(1)Precision: The self - heating detection sensitivity is far better than the standard detection threshold of 0.02°C/min. It has high thermal insulation performance and a small temperature difference between the wall and the sample.
(2)Efficiency: With an innovative heating wire assisted heating solution, the experimental efficiency can be increased by up to 5 times.
(3)Safety: It is equipped with safety protection measures such as burst discs, pressure relief valves, and explosion - proof boxes. The professional alarm system design comprehensively ensures the safety of personnel and equipment.
(4)Innovation: It has the innovative function of adiabatic thermal runaway - gas production combined analysis, enabling a comprehensive acquisition of the characteristic parameters of battery thermal runaway.
Parameters
| Description | Details |
|---|---|
| Adiabatic chamber effective size | Diameter: 800mm, Depth: 520mm |
| Self-exothermic detection sensitivity | Better than 0.02℃/min |
| Constant temperature wall sample temperature difference | ≤ 1℃ |
| Temperature control range | RT ~ 300℃, with low temperature module up to -25℃ |
| Working pressure range | 0 ~ 2MPa |
| Temperature tracking rate | 0.02 ~ 15℃/min |
| Needle maximum stroke | Stroke can be set up by software |
| Charge and discharge electrode column overcurrent capacity | -1000A ~ 1000A |
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Face Mask Airflow Resistance Measurement tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards: GB19083-2010 technical requirements for medical protective masks Applications:... | |
| Scratch Scuff Mar Finish Tester ,ISO 1518 ,Scratch Resistance Testing Machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Scratch Scuff Mar Finish Tester is designed to evaluate the scratch, scuff, and mar res... | |
| Degradation Testing chamber for PV Modules | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Light Decay Test Chamber is a high-precision indoor exposure system speci... | |
| Water-cooled xenon aging chamber | Whats/App: +86 156 1874 6768 Web: standard-groups.com Introduction SI4000Xenon Arc Weather Ometer utilizes a xenon lamp to simulate ideal natura... | |
| ASTM C518 High-Precision Heat Flow Measurement System | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ASTM C518: Standard Test Method for Steady-State Thermal Transmission Properties... |
Похожие товары
| MMA-120 Handheld Arc Welder | Продавец: 871183 | The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con... | |
| SHX Series Circulating Fluidized Bed Steam Boiler | Продавец: Hebei Genjux Boiler Co.,Ltd | Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi... | |
| YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler | Продавец: Hebei Genjux Boiler Co.,Ltd | Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ... | |
| DHL Series Coal-Fired Steam Boilers | Продавец: Hebei Genjux Boiler Co.,Ltd | Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b... | |
| SZL Series Biomass Steam Boiler | Продавец: Hebei Genjux Boiler Co.,Ltd | Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi... |