Roof-Mounted Photovoltaic Module Fire Test Apparatus
Get a quote:
Whats/App: +86 181 0160 0864
Web: gellowen.co.uk
The Roof-Mounted Photovoltaic Module Fire Test Apparatus is a specialized testing system developed in accordance with GB/T 30735-2014 for evaluating the external fire performance of roof-mounted photovoltaic modules and roofing products. Based on test principles derived from ENV 1187 (t1 method) and ISO 12468-1. the apparatus simulates different fire exposure conditions such as wind influence and thermal radiation. It provides standardized test methods for assessing the external reaction to fire of roof systems and roof coverings, supporting fire safety evaluation of photovoltaic installations on roofs.
Application
The test apparatus is suitable for fire performance evaluation of roofing systems and photovoltaic installations under external fire exposure conditions. Typical applications include:
External fire reaction testing of roof-mounted photovoltaic modules
Fire performance evaluation of roof coverings and roofing assemblies
Assessment of building-integrated photovoltaic (BIPV) systems
Combustion behavior testing of roof construction materials
Fire safety research related to renewable energy installations
Type testing and compliance verification in certification and testing laboratories
Standards
The apparatus is designed to meet the requirements of the following standards:
(1) GB/T 30735-2014 – Test Method for Reaction to External Fire of Roofs and Roof Coverings
(2) ENV 1187: t1 – Test Methods for External Fire Exposure to Roofs
(3) ISO 12468-1:2013 (Method B) – Fire Performance of External Roofs and Roof Coverings — Part 1: Test Methods
(4) ISO 12468-1:2013 (Method C) – Fire Performance of External Roofs and Roof Coverings — Part 1: Test Methods
(5) UL 1703: multi-family and hotel room individual dwelling unit smoke detection monitors: electric signal detection of house dust;
(6)UL 790: standard method of fire test for roof covering materials;
(7)ASTM e 108-04: standard method of fire test for roof covering materials;
(8)NFPA 256: fire test of roof deck.
(9)IEC 61730-2 Appendix b: fire tests on PV modules.
Parameters
| Item | Specification |
|---|---|
| Radiant Panel Radiation Surface | 600 mm × 600 mm |
| Wood Crib Fire Gas Combustion Device | 1 set |
| Test Specimen Rack Angle | Adjustable, 0–50° |
| Air Duct Material | SUS304 stainless steel |
| Air Duct Thickness | 2 mm |
| Fan Airflow Capacity | Max. 250 m³/min |
| Fan Power | 5.5 kW |
| Fan Frequency Control | 3-phase 380 V, 5.5 kW |
| Air Duct Adjustable Angle | 0–35° |
| Impeller Anemometer | 3 units |
| Wind Speed Accuracy | 0.1 m/s |
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Computer controlled memory impact testing machine | Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk Computer controlled memory impact testing machine is mainly used for hard plastics... | |
| Particle Strength Tester | Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk The Particle Strength Tester is a high-precision instrument designed to measure th... | |
| Metal Bone Screws Torque Tester | Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk The Metal Bone Screws Torque Tester is a precision testing device designed to eval... | |
| Intelligent Sample Cutting Machine | Get a quote: Whats/App: +86 181 0160 0864 The Intelligent Sample Cutting Machine is a high-efficiency automated cutting device integrating automa... | |
| Qinsun UV-master | In response to the climate resistance testing requirements for outdoor textiles, this equipment can simulate outdoor climate conditions and accel... |