CE Certified Thermal Constants Analyzer for R&D Laboratory
Get a quote:
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Standards
The analyzer supports multiple internationally recognized test methods and standards, including:
(1) ISO 22007-2: Plastics — Determination of thermal conductivity and thermal diffusivity — Transient plane heat source method
(2) ISO 22007-7: Plastics — Determination of thermal conductivity and thermal diffusivity using transient plane heat source
(3) GB/T 32064: Transient plane heat source method for thermal conductivity and thermal diffusivity of building materials
(4) ASTM E3088: Standard test method for determination of thermal conductivity and thermal diffusivity using the transient plane source method
(5) ASTM D7896: Transient hot-wire method for thermal conductivity, thermal diffusivity, and volumetric heat capacity of liquids
(6) ASTM D5334: Transient line-source probe method
(7) ASTM D5930: Determination of thermal conductivity of plastics by transient line-source technique
(8) IEEE 442: Soil thermal resistivity measurement
Parameters
| Method | TPS | THW | MTPS | THS | TLS |
|---|---|---|---|---|---|
| Applicable Materials | Solids, pastes, powders | Liquids, phase-change materials | Solids, pastes, powders | Solid rectangular samples | Soil, pastes, polymers |
| Measurement Mode | 3D bulk, anisotropic, plate, thin film, 1D | Bulk | 3D bulk, anisotropic, plate, 1D | Bulk, anisotropic | Bulk |
| Thermal Conductivity (W/m·K) | 0.005–2000 | 0.01–2 | 0.03–500 | 0.01–2 | — |
| Thermal Diffusivity (mm²/s) | 0.01–1200 | Up to 0.5 | 0.01–300 | Up to 0.5 | — |
| Volumetric Heat Capacity (MJ/m³·K) | Up to 5 | Up to 5 | Up to 5 | Up to 5 | — |
| Thermal Effusivity (W·s½/m²·K) | 5–60000 | Not applicable | 20–40000 | Not applicable | — |
| Contact Thermal Resistance (m²·K/W) | Measured | Not applicable | Measured | Not applicable | Not applicable |
| Sample Thickness (mm)* | ≥0.01 | — | ≥0.1 | — | — |
| Test Time (s) | 0.25–2560 | 1 | 0.25–2560 | 0.25–2560 | 180 |
| Accuracy (Thermal Conductivity) | 3% | 2% | 5% | 5% | 5% |
| Repeatability (Thermal Conductivity) | 1% | 1% | 2% | 2% | 2% |
| Temperature Range (°C)** | 0 to 300 / up to 750 or 1000 | 10 to 200 | 0 to 100 / −50 to 200 | −75 to 300 | −40 to 100 |
| Sample Configuration | Symmetric / asymmetric | Insert type | Asymmetric (single-sided) | Symmetric / asymmetric | Insert type |
Features
Supports multiple transient methods within one integrated system
Measures absolute thermal conductivity, thermal diffusivity, specific heat, and thermal effusivity
Suitable for solids, liquids, pastes, powders, and soil samples
Wide thermal conductivity and temperature measurement ranges
Direct measurement of sensor–sample contact thermal resistance for improved accuracy
Accessories
(1) Transient plane heat source (TPS) sensors
(2) Transient hot-wire (THW) sensors
(3) Modified transient plane source (MTPS) sensors
(4) Transient hot strip (THS) sensors
(5) Transient line source (TLS) probes
(6) Sample holders for solid, liquid, and soil configurations
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Anti-drill tester (Friction method) | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Anti-Drill Tester (Friction Method) is designed to evaluate the drill and friction resi... | |
| ASTM D1238 melt flow indexer | Whats/App: +86 156 1874 6768 Web: standard-groups.com Introduction Melt flow indexer(MFI) are used for military uniforms, canvas, canvas, labor ... | |
| Safety Helmet Anti-static Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Safety Helmet Anti-static Tester is designed to evaluate the antistatic performance of ... | |
| Catheter Flexibility Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Catheter Flexibility Tester utilizes a control system combining a PLC and an industrial... | |
| European Standard Washer | Whats/App: +86 156 1874 6768 Web: standard-groups.com The European Standard Washer (EN 14399-compliant) is a high-performance fastening component... |
Похожие товары
| Высокоскоростная экструзионная линия для производства гофрированных труб с двойными стенками из ПЭВП с водяным охлаждением | Продавец: Shandong HUASU Plastic Technology Co.,Ltd. | Формы имеют структуру с двойным каналом потока и фильерную головку, обработанную азотированием и ... | |
| PanEVAP & MVR system | Продавец: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | A multiple-effect evaporator is a device that efficiently uses steam heat to evaporate water. Wat... | |
| PanGAP wide gap welded plate heat exchanger | Продавец: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanGAP wide gap welded plate heat exchangerconsists of a welded plate pack with different channel... | |
| PanBloc welded plate heat exchanger | Продавец: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanBloc welded plate heat exchangeris compact and efficient, although fully welded, is totally ac... | |
| PanBox welded plate heat exchanger | Продавец: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanBox welded plate heat exchangerconsists of a laser welded plate pack with optimized corrugated... |