SAE J1756 Fogging Test Equipment Manufacturer China
Get a quote:
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Features
Dual-Bath System:
High-Temperature Bath: 670×490×540mm, 3kW heating power (up to 150°C).
Low-Temperature Bath: 400×220×520mm, 500W cooling capacity (0–100°C).
Automated Controls:
Digital thermoregulator with microprocessor for precise temperature programming.
Programmable timer (1–9999 min) with auto-stop and end-test buzzer.
Modular Accessories:
18/8 stainless steel test cups, flat beakers, and chrome steel rings for sample mounting.
Six interchangeable cooling plates and haze/gloss measurement kits.
Safety Compliance:
CE-certified with anti-acid epoxy coating, emergency stop, and overpressure relief.
Parameters
| Parameter | Specification |
|---|---|
| High-Temperature Range | Room temperature – 150°C (280°C optional) |
| Low-Temperature Range | 0–100°C |
| Temperature Stability | ±0.1°C (at 200°C) |
| Heat-Up Time | <45 min (to 150°C) |
| Cooling Capacity | 500W (low bath) |
| Power Supply | AC 220V, 50Hz, 3.5kW |
| Dimensions | 500 (W) × 650 (D) × 600 (H) mm |
| Net Weight | 50 kg (excluding thermal media) |
| Data Interface | USB 2.0. remote sensor compatibility |
| Safety Systems | Magnetic switch, thermostat, audible alerts |
Test Procedures
1.First of all , get the accessories and test samp.
2.Prepare an aluminum foil,place it in the scale to weigh it, and record the value.
3.Place aluminum foil and glass plate over the fog cup.
4.Set the cycle parameters of the low temperature control box, set host temperature and time parameters.
5.Start the instrument,the sample is heated inithe fog cup.
is started.When the timing is reached, remove.
the aluminum paper fZrom the station.
6.Put it into the scale again and weigh it, and record the value.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Metal Bone Screws Self - tapping Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard ISO 6475: Implants for surgery – Wear of total hip-joint prostheses ASTM F... | |
| Super Xenon Weather Meter | Whats/App: +86 156 1874 6768 Web: standard-groups.com SX75 accelerates the degradation of materials by exposing them to simulated outdoor and ind... | |
| Gas Hazard Property Analyzer | Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Introduction This tester is used to test the flammable concentration range of gase... | |
| HEPA ULPA Filter Scanning Test System, EN 1822 Filter Integrity Tester Manufacturer | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com E-mail:info@standard-groups。com Parameters ParameterUnitValue Te... | |