Building Material Non-Combustibility Test Furnace Factory
Get a quote:
Whats/App: +86 156 1874 6768
Web: standard-groups.com
E-mail:info@standard-groups。com
Control System
1. High degree of automation, test procedure safe and reliable, easy to operate;
2. To use of high-quality strip heater,furnace temperature was raised to 900 ºC;
3. PLC control system + SSR temperature control system extending the life of furnace;
4. PLC output signal to control the heating voltage is 0-110 VAC. Eliminate the influence of voltage fluctuation on temperature;
5. Temperature control: 750 ºC±2 ºC;Resolution:0.1ºC;
6. The samplies move up-down into the furnace automatically by motor;
7. 7 "touch screen for control parameter setting and display / test data acquisition and preservation / screen monitoring / real-time temperature curve shows / historical curve and data query;
8. With an audible alarm and alarm display functions accidents;
9. To equipped with printer, to print the temperature curve;
Parameters
| Item | Specification |
|---|---|
| Gas used - Methane flow rate | (35 ± 0.5) L/min, purity > 95% |
| Gas used - Air flow rate | (17 ± 0.2) L/min |
| Specimen size | 4 specimens per test group |
| Thermocouple type | Nickel-chromium-nickel-silicon, wire diameter 0.5mm, outer diameter ≤ 3mm |
| Furnace wall temperature range | Room temperature to 100°C, ±1°C |
| Intake temperature range | 0 to (50 ± 0.5)°C |
| Pressure difference range | 0 to 30Pa, ±1Pa |
| Pressure difference measurement range | 0-100Pa, accuracy 0.2% |
| Temperature recorder and thermostat | Multi-channel continuous temperature recording and curve display |
| Constant temperature | (23 ± 2)°C |
| Constant current | (10 ± 1) m³/min |
| Ambient temperature range | 19 to 30°C |
| Power supply | 380VAC 50HZ |
| Dimensions of combustion shaft furnace (outer) | 1020mm x 1020mm x 3930mm |
| Dimensions of combustion shaft furnace (inner) | 800mm x 800mm x 2000mm |
Accessoriess
Complete set includes:
01. European standard indoor furnishings flammability testing kit
02. No. 4 wooden spacers (10 pieces/pack)
03. No. 5 wooden spacers (10 pieces/pack)
04. No. 6 wooden spacers (10 pieces/pack)
05. No. 7 wooden spacers (10 pieces/pack)
06. Non-flame retardant polyurethane foam 450×450
07. Non-flame retardant polyurethane foam 450×300
08. Non-flame retardant polyurethane foam 450×150
09. Flame retardant polyurethane foam 450×450
10. Flame retardant polyurethane foam 450×300
11. Flame retardant polyurethane foam 450×150
12. Flame retardant polyurethane foam 450×450
13. Flame retardant polyurethane foam 450×300
14. Flame retardant polyurethane foam 450×150
15. Standard cigarettes (10 packs)
Test Procedures
1. So that the furnace temperature equilibrium, if the logger can not be calculated in real time, the final temperature should be checked whether the balance.
2. Before the test should ensure that the entire device is in good working condition, such as a steady flow clean air flow, the device can be smoothly inserted into the slide, the sample holder can be accurately located in a predetermined position in the furnace.
3. Prepared according to a predetermined and regulated by the state of the sample into the sample holder, the sample racks suspended from the support member. The sample holder into a predetermined position in the furnace, the operation time should not exceed 5s. When the sample is located in a predetermined position in the furnace, immediately start the timer. Recorded during the test furnace thermocouple temperature measurement, such as the requirement to measure the surface temperature of the sample and the center temperature, corresponding to the temperature it should also be recorded.
4. Carried 30min test, if the furnace temperature reaches the final equilibrium temperature in 30min, that is measured by a thermocouple temperature drift (linear regression) within 10min of not more than 2 ℃, you can stop the test. If unable to reach equilibrium within 30min, the test should be continued, while every 5min check whether the final temperature equilibrium, when the furnace temperature reaches a final equilibrium temperature or testing time reaches 60min end of the trial should be. Recording duration of the test, the sample holder and then remove from the heating furnace, the end of the time trial for the end time of the last 5min or 60min. Temperature should be checked after the end of the test record if the logger can not be recorded in real time, test. If it can not meet the above requirements, it should be re-tested. If an additional test using a thermocouple, the thermocouple should all have reached the final temperature equilibrium or when the test time was 60min when the end of the trial.
5. The collection and after the test specimen cracked or falling all carbides, ash and other debris, together with the sample into the drying vessel was cooled to ambient temperature, weigh the residual mass of the sample. The quality of each sample were recorded before and after the test and observing the combustion behavior recorded during the test specimen. Sustained fire occurrence and duration records, accurate to the second. Sample shows a continuing 5s or longer continuous flame on the surface it should be regarded as sustained fire.
6. The following furnace thermocouple to measure the temperature, in degrees Celsius, the initial furnace temperature T1. average temperature last 10min predetermined temperature balance of the furnace; furnace maximum temperature Tm, the maximum temperature throughout the test discrete value; the final furnace temperature Tf ,. The temperature during the test last 1min average.
Fourth, the end of the trial, finishing the test furnace wipe clean for the next use.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Dental Implants Fatigue Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard ISO 14801:2016: Specifies dynamic fatigue testing protocols for endosseous dental... | |
| Walk In Pharmaceutical Stability Chamber | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications Pharmaceutical Stability Testing Laboratory is designed for conducting accele... | |
| Solar Cell Spread of Flame & Burning Brand Test Machine, IEC 61730 | Whats/App: +86 156 1874 6768 Web: standard-groups.com Productintroduction: This apparatus is based on UL 1730. IEC 61730-2 design and developmen... | |
| Plastic Biodegradation Testing System,ISO 16929 Biodegradable Plastic Testing Instruments | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Plastic Biodegradation Testing System is a laboratory system used to evaluate the ultim... | |
| Automatic freezing point pour point cold tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Introduction: The automatic freezing point pouring point Freezing point tester is ... |
Похожие товары
| PanEVAP & MVR system | Продавец: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | A multiple-effect evaporator is a device that efficiently uses steam heat to evaporate water. Wat... | |
| PanGAP wide gap welded plate heat exchanger | Продавец: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanGAP wide gap welded plate heat exchangerconsists of a welded plate pack with different channel... | |
| PanBloc welded plate heat exchanger | Продавец: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanBloc welded plate heat exchangeris compact and efficient, although fully welded, is totally ac... | |
| PanBox welded plate heat exchanger | Продавец: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanBox welded plate heat exchangerconsists of a laser welded plate pack with optimized corrugated... | |
| PanPHE gasketed plate heat exchangers | Продавец: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanPHE gasketed plate heat exchangersare designed with easy access for regular servicing and for ... |