Polypectomy Snares (Hot)
This device indicated for use endoscopically for the removal of polyps.
Features of Polypectomy Snares (Hot)
Snares are available in multiple shapes, stiffness ranging from 'soft' to 'Hard', as well as full range snare open width to meet different polyps cutting requirement.
Braided wires for excellent coagulation and bleeding control.
360° 1:1 rotation for precise adjustment.
Specification of Polypectomy Snares (Hot)
Rgeular items
|
REF |
Catheter |
Snare |
Stiffness |
Units/Box |
|||
|
Fixed |
Rotatable |
Catheter Diam. (mm) |
Working length (mm) |
Opening Width (mm) |
Configuration |
||
|
L16CA241815A0 |
L16RA241815A0 |
1800 |
15 |
Oval |
Soft |
10 |
|
|
L16CA241825A0 |
L16RA241825A0 |
1800 |
25 |
||||
|
L16CA241832A0 |
L16RA241832A0 |
1800 |
32 |
||||
|
L16CA242415A0 |
L16RA242415A0 |
2400 |
15 |
||||
|
L16CA242425A0 |
L16RA242425A0 |
2400 |
25 |
||||
|
L16CA242432A0 |
L16RA242432A0 |
2400 |
32 |
||||
|
L16CB241822A0 |
L16RB241822A0 |
1800 |
22 |
Hexagon |
|||
|
L16CB241832A0 |
L16RB241832A0 |
1800 |
32 |
||||
|
L16CB242422A0 |
L16RB242422A0 |
2400 |
22 |
||||
|
L16CB242432A0 |
L16RB242432A0 |
2400 |
32 |
||||
|
L16CC241825A0 |
L16RC241825A0 |
1800 |
25 |
Half Moon |
|||
|
L16CC241832A0 |
L16RC241832A0 |
1800 |
32 |
||||
|
L16CC242425A0 |
L16RC242425A0 |
2400 |
25 |
||||
|
L16CC242432A0 |
L16RC242432A0 |
2400 |
32 |
||||
|
L16CA241815B0 |
L16RA241815B0 |
1800 |
15 |
Oval |
Hard |
||
|
L16CA241825B0 |
L16RA241825B0 |
1800 |
25 |
||||
|
L16CA241832B0 |
L16RA241832B0 |
1800 |
32 |
||||
|
L16CA242415B0 |
L16RA242415B0 |
2400 |
15 |
||||
|
L16CA242425B0 |
L16RA242425B0 |
2400 |
25 |
||||
|
L16CA242432B0 |
L16RA242432B0 |
2400 |
32 |
||||
|
L16CB241822B0 |
L16RB241822B0 |
1800 |
22 |
Hexagon |
|||
|
L16CB241832B0 |
L16RB241832B0 |
1800 |
32 |
||||
|
L16CB242422B0 |
L16RB242422B0 |
2400 |
22 |
||||
|
L16CB242432B0 |
L16RB242432B0 |
2400 |
32 |
||||
|
L16CC241825B0 |
L16RC241825B0 |
1800 |
25 |
Half Moon |
|||
|
L16CC241832B0 |
L16RC241832B0 |
1800 |
32 |
||||
|
L16CC242425B0 |
L16RC242425B0 |
2400 |
25 |
||||
|
L16CC242432B0 |
L16RC242432B0 |
2400 |
32 |
||||
What is a Hot Snare Polyp
Hot polypectomy, the endoscopist advances the snare sheath, opens the snare and encircles the polyp. The snare is then slowly and progressively closed, with the aim of capturing 1-2 mm of normal tissue around the polyp,then use Electrocoagulation until complete closure is achieved and the polyp is guillotined. Best used for polyps 10-19 mm in diameter.
Hot Snare Polypectomy Technique
Hot polyp snare, which is using electrocoagulation on the basis of using cold snare. After hot snare polypectomy, another independent endoscopic surgeon judged whether the endoscopic eradication was successful. Afterward, additional EMR was performed at the polypectomy site to evaluate for the presence of residual polyp tissue,including an additional 1 to 2 mm clear margin, was resected by the snare and Endocut current after submucosal injection of a mixed solution.
Snare Polypectomy Procedure
In endoscopic snare polypectomy, doctor will capture around the bottom of the polyp and use current to cut the growth off. Any remaining tissue or stalk is then cauterized.
Endoscopic mucosal resection (EMR) or endoscopic submucosal dissection (ESD) techniques could be used on some polyps are considered more technically challenging or are associated with an increased risk of complications.
Leo Medical Co., Ltd. Is a professional endoscopy accessories manufacturer, we provide endoscope accessories, pulmonary products, endoscopic snare, emr polyp, polyp emrand etc. Want to know more ? Please contact us.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Ligation Device | Ligation deviceis used for endoscopic therapy of gastrointestinal perforation, ESD/EMR assistance, bleeding control and the ligation of polyps. ... | |
| Pulmonology Products | LeoMed Pulmonology equipmentcover pulmonology guide wire, pulmonology dilatation balloon, airway retrieval basket, and BAL catheter. Under the C... | |
| Single-use Injection Therapy Needle Catheter | Endoscopic injection needleis used for endoscopic submucosal injection and hemostasis. Features of Single-use Injection Therapy Needle Catheter ... | |
| Ligation Device | Ligation devicesis used for endoscopic therapy of gastrointestinal perforation, ESD/EMR assistance, bleeding control and the ligation of polyps. ... | |
| Single-Use Pulmonary Balloon Dilatation Catheter | Used for endoscopic dilate strictures of the airway tree Features of Single-Use Pulmonary Balloon Dilatation CatheterCatheter Three distinct di... |
Похожие товары
| R404a Scroll Compressor for Cold Chain Transportation | Продавец: Scroll Air Compressor,Electric Scroll Compressor | Optimized for Cold Chain Vehicles & Containers The34cc R404a scroll compressor for cold chai... | |
| Electric scroll compressor with R404a Refrigerant | Продавец: Scroll Air Compressor,Electric Scroll Compressor | Introduction Leling's compact refrigeration scroll compressor (18CC) is specially engineered for... | |
| Vapor Injection Compressor With Enhanced Enthalpy | Продавец: Scroll Air Compressor,Electric Scroll Compressor | The vapor injection compressor with enhanced enthalpy is a new type of compressor improved on the... | |
| R404a Refrigeration Compressor | Продавец: Scroll Air Compressor,Electric Scroll Compressor | R404a Refrigeration Compressor The refrigeration and freezing scroll compressor is a type of com... | |
| DC variable frequency electric scroll compressor | Продавец: Scroll Air Compressor,Electric Scroll Compressor | The electric scroll compressoris mainly composed of moving scroll plate, stationary scroll plate,... |
















