Malaria (p.f/p.v) Antibody Rapid Test
Malaria is caused by a protozoan that invades human red blood cells.
Malaria is one of the world's most prevalent diseases. According to the WHO, the worldwide prevalence of the disease is estimated to be 300-500 million cases and over 1 million deaths each year. Most of these victims are infants, young children. Over half of the world's population lives in malarious areas. Microscopic analysis of appropriately stained thick and thin blood smears has been the standard diagnostic technique for identifying malaria infections for more than a century.
The technique is capable of accurate and reliable diagnosis when performed by skilled microscopists using defined protocols. The skill of the microscopist and the use of proven and defined procedures, frequently present the greatest obstacles to fully achieving the potential accuracy of microscopic diagnosis. Although there is a logistical burden associated with performing a time-intensive, labor-intensive, and equipment-intensive procedure such as diagnostic microscopy, it is the training required to establish and sustain the competent performance of microscopy that poses the greatest difficulty in employing this diagnostic technology.
Malaria Is Caused By A Protozoan Which Invades Human Red Blood Cells
Malaria is one of the world's most prevalent diseases. According to the WHO, the worldwide prevalence of the disease is estimated to be 300-500 million cases and over 1 million deaths each year. Most of these victims are infants, young children. Over half of the world's population lives in malarious areas. Microscopic analysis of appropriately stained thick and thin blood smears has been the standard diagnostic technique for identifying malaria infections for more than a century.
The technique is capable of accurate and reliable diagnosis when performed by skilled microscopists using defined protocols. The skill of the microscopist and use of proven and defined procedures, frequently present the greatest obstacles to fully achieving the potential accuracy of microscopic diagnosis. Although there is a logistical burden associated with performing a time-intensive, labor-intensive, and equipment-intensive procedure such as diagnostic microscopy, it is the training required to establish and sustain competent performance of microscopy that poses the greatest difficulty in employing this diagnostic technology.
Intended Use of malaria pf pvAntibody Rapid Test
For the rapid qualitative determination of Malaria lactate dehydrogenase (LDH) and Malaria histidine rich protein-2 (HRP-2) in human blood as an aid in the diagnosis of Malaria infection.
Introduction of Malaria (pv pf) Antibody Rapid Test
Malaria is a serious parasitic disease characterized by fever, chills, and anemia and is caused by a parasite that is transmitted from one human to another by the bite of infected Anopheles mosquitoes. There are four kinds of malaria that can infect humans: Plasmodium falciparum, P. vivax, P. ovale, and P. malariae. In humans, the parasites (called sporozoites) migrate to the liver where they mature and release another form, the merozoites. The disease now occurs in more than 90 countries worldwide, and it is estimated that there are over 500 million clinical cases and 2.7 million malaria-caused deaths per year. At the present, malaria is diagnosed by looking for the parasites in a drop of blood. Blood will be put onto a microscope slide and stained so that the parasites will be visible under a microscope.
The malaria pf pv test kitcontains a membrane strip, which is pre_x005fcoated with two monoclonal antibodies as two separate lines across a test strip. One monoclonal antibody (test line 1) is specific to Histidine rich protein-2 of P. falciparum and another monoclonal antibody (test line 2) is pan specific to the lactate dehydrogenase of P.vivax. Conjugate pad is dispensed with monoclonal antibody, which is pan specific to the lactate dehydrogenase of Plasmodium species. So the Malaria Antigen Test is designed for the differential diagnosis between Plasmodium falciparum and the other Plasmodium species.
As a monoclonal antibody manufacturer,we provide pf pv antigen, pf pv antigen test, in vitro diagnostic reagents, etc. Want to know pv pf test costor more, contact us.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
Chicken IgY | The IgY isotype control could be used in FC, ELISA and Flisa experiments. Each batch of the product has been FC, ELISA, Flisa testing to ensure tha... | |
Filariasis IgG/IgM Rapid Test | The Filariasis IgG/IgM Rapid Test Chinais a lateral flow immunoassay for the simultaneous detection and differentiation of IgG and IgM anti-lymphat... | |
Filariasis IgG/IgM Rapid Test | The filariasis rapid testis a lateral flow immunoassay for the simultaneous detection and differentiation of IgG and IgM anti-lymphatic filarial pa... | |
Malaria (p.f/p.v) Antibody Rapid Test | Malaria is caused by a protozoan that invades human red blood cells. Malaria is one of the world's most prevalent diseases. According to the WHO... | |
Strep A Antigen Rapid Test | Instant strep testutilizes two-site sandwich immunoassay technology for the detection of Group A Streptococcal antigen. The test consists of a memb... |
Похожие товары
Blue Non-Woven Fabric Silicone Gel Tape Roll for Scar Treatment | Продавец: Zhejiang Hangbiao Medical Supplies Co., Ltd. | Surgical Tape Factory() Blue Non-Woven Fabric Silicone Gel Tape Roll is a premium scar repair pro... | |
Электронная окулярная камера MECHANIC MEC 4K 2K HD для стереомикроскопа | Продавец: ШЭНЬЧЖЭНЬСКАЯ ТЕХНОЛОГИЯ PHONEFIX, LTD (КИТАЙСКИЙ PHONEFIX) | Описание Электронная окулярная камера Mechanic MEC 2K/2K PRO/4K HD может превратить бинокулярный ... | |
Цифровой мультиметр Fluke 15B+ 17B+ 18B+, тестер напряжения и частоты | Продавец: Шэньчжэнь Weike Repair Technology Co., Ltd. | Полупрозрачная/полностью прозрачная/молочно-белая/светло-желтая паяльная паста iFixes 10CC, не со... | |
Grey Rubber Stopper For Blood Collection Tube | Продавец: Taizhou KangLong Medical Treatment Technology Co., Ltd. | Medical Grey Rubber Stopper For Blood Collection Tube Good formulation technology guarantees... | |
HTT-02 Hot Tack Tester | Продавец: Cell Instruments Co., Ltd | The HTT-02 Hot Tack Testeris specifically designed to assess this property by measuring the stren... |