ANESTHESIA MACHINE MODEL:DA2000
Medical Anesthesia Machine, Open Anesthesia Machine, Touch Screen Anesthesia Machine Supplier
Feature:
More convenient operating and display systems for clinical operations,suitable for a wide range of anesthesia at adult,pediatric
Comprehensive Safety&Alarm system,make sure the operation accuracy and stability
8inch TFT display with touch screen,shuttle knob design, quick and efficient operation
Integrated absorber design with good cable management solution,convenient to discharge and install timely..
Powerful ventilation mode meet all complex clinical requirement
Three levels alarm system, visual and sound alarm information.
The core components are imported from top international and original, and the industrial control chip is chosen
High precious sensor and valve technology make sure the pressure ,flow and volume monitor and control at high safety, stability and precision
High precious anesthesia vaporizer with temperature,flow and pressure compensation
Top-light system design provide more good vision
Built-in backup battery provide the emergency power supply to the unit.
Low O2 pressure alarm and N2O cut-off protection.
Technical Specifications
Display:8" TFT, with touch screen.
Working Mode:Closed,Semi-closed,,semi-open system,Open
Ventilation Mode:VCV,PCV,SIMV-VC,SIMV-PC,PSV,Manual/SPONT.
Optional: SIMV-PRVC, PRVC
Waveform:Pressure,Flow-rate,Volume
Loop:PV loop, PF loop,FV loop
Safety Pressure:Does not exceed 6KPa.
Battery Type:Li-ion,work time more than 2 hours
Parameter Setting Range:
Tidal Volume:Range: 20-1500ml;
Respiratory rate::1~100bpm;
Inspiratory time:0.1~10.0s;
Respiratory ratio: 9.9:1to1:9.9;
Percentage of inspiratory pause:0to50%;
PEEP:OFF,3~20 cmH2O
Pressure Support:0~60 cmH2O
Pressure Control:5~60 cmH2O
Flow trigger:0.5 ~ 20L/min
Pressure Trigger:-1~-20 cmH2O
PSV Insp Termination Level:25%
Monitoring Parameter
Inspiratory tidal volume,Expiratory tidal volume,Minute ventilation,Spontaneous minute ventilation,Respiratory rate,Spontaneous breathing frequency,Respiratory ratio,Peak airway pressure,Mean airway pressure,PEEP,Inspiratory plateau pressure,FiO2(optional)
Alarm Setting:
Tidal volume:High 0~ 2000mL,OFF;Low 0~ 1500 mL
Minute ventilation:High 1~ 99 L;Low 0~ 98 L
Respiratory rate:High 1~ 100bpm;Low 0~ 99 bpm
FiO2(optional):High 19~ 100%;Low 18 ~99%
Airway pressure:High 6~ 99 cmH2O,Low 0~98 cmH2O
FiCO2(optional):High 0.1to13.3%; Low 0to13.2%
Continuous Positive Airway Pressure:Greater than (PEEP+15) cmH2O,
15 s sustainedwhen an alarm is triggered.
Negative pressure alarm:Airway pressure is less than(-10)cmH2O.
Apnea alarm:Setting time is 10~ 60s
Gas deficiency alarm:less than 280 kPa.
AC power failure alarm:The mains breaks down or the power cord disconnects
Low battery alarm: Time is 20min.
Alarm battery is exhausted: time is 10min.
Silent Alarm:≤ 120 s
O2 sensor failure:FIO2 <15% Vol;
Driving gas:O2 or Air,Inlet pressure,280-600kPa.Max flow ≤120 L /min.
Anesthesia Vaporizer:Dvapo200plus Selectatec bar mounting type
CO2 Absorber:Twins canister,2 L volume for sadalime,wth no-return respiration valve and inspiraition valve,avoid gas back flowing.
Flow meter:O2,N2O TWO TUBES FLOWMETE
1*O2 tubes:0-1L/min, 1-10L/min 1*N2O tubes:0-1L/min, 1-10L/min
Mechanical flowmeter O2,N2O and air (Optioanl)
N2O will be auto cut when O2 supply failure
O2 and N2O linkage device,keep O2 not low than 25%
Bellow:Adult bellow(300-1800ml) and pediatric bellow(0-300ml).
Gauge: Two gas supply pressure gaugage( O2,N2O )
Three gas working prssure gauage (O2,N2O and air)(optioanal)
One gas airway pressure gauge
Gas supply pressure:0.27-0.55Mpa
O2 Flush:25-75LPM
Gas switch:Control gas source with starting or stopping
Optional:
Yoke system:Pin index O2 and N2O Yokes System,
backup gas will auto working when central gas supply fail
AGSS:(Anesthesia Gas Scavenging System)
ETCO2:End-Tidal Carbon Dioxide
Dolphinmed is one professonal producer of ICU ventilator, anesthesia machine, medical air compressor, anesthesia vaporizer, Anesthesia Workstation, veterinary anesthesia machine, etc. Dolphinmed are committed to provide the more perfect products and service for clients, to be the most valued medical equipment enterprise.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
DP315 Pediatric bellow | DP315 Pediatric bellow OEM ODM Anesthesia Ventilator, ICU Ventilator, Anesthesia Vaporizer Price 1- Pediatric cover、 2- Pediatric foldable bag 3-Co... | |
DP309 flowmeter | DP309 flowmeter Flowmeter for anesthesia machine O2 0-1,1-10L/min N2O 0-1,1-10L/min Air 0-1,1-10L/min O2 Single tube flowmeter O2 two tube fl... | |
ICU Ventilator(W/O compressor) | ICU Ventilator(W/O compressor) Technical Specifications Ventilation mode for adult,pediatric&infant VCV, VC-SIMV,PCV,PC-SIMV,PSV/CPAP with a... | |
ANESTHESIA MACHINE MODEL:DA1000 | OEM ODM Anesthesia Ventilator, ICU Ventilator, Anesthesia Vaporizer Price Feature: Suitable for a range of anesthesia at adult&pediatric Int... | |
ANESTHESIA MACHINE MODEL:DA1000 | OEM ODM Anesthesia Ventilator, ICU Ventilator, Anesthesia Vaporizer Price Feature: Suitable for a range of anesthesia at adult&pediatric Integr... |
Похожие товары
PCR Tube Strips Supplier | Продавец: Zhejiang Songhai Medical Device Co., Ltd. | The most common application of PCR tubes includes various molecular biology biochemistry experime... | |
Biopharmaceutical Equipment and Devices | Продавец: Jiangsu Hanbon Science&Technology Co., LTD | Hanbon is a manufacturer of liquid ssmb chromatographyseries products with a large production sca... | |
SFC-Dynamic Axial Compression Column | Продавец: Jiangsu Hanbon Science&Technology Co., LTD | SFC-Dynamic Axial Compression Column (DAC) has the most mature loading technology in the field of... | |
Preparative Liquid Chromatography System | Продавец: Jiangsu Hanbon Science&Technology Co., LTD | Hanbon preparative liquid chromatography system has the characteristics of high efficiency, high ... | |
Preparative HPLC | Продавец: Jiangsu Hanbon Science&Technology Co., LTD | Hanbon offers Hanbon preparative HPLCand MPLC from laboratory to industrial level, which are esse... |