HYGK-306 Circuit Breaker Analyzer
Circuit breakeranalyzer functions:
|
1 |
wuhan huaying electric power company OEM service |
|
2 |
Closing and opening time measurement of 12 channels |
|
3 |
Max difference of closing or opening time measurement of three phases |
|
4 |
C-O and O-C time measurement |
|
5 |
Rated operation sequence test |
|
6 |
Bounce time and frequency measurement of breaker closing |
|
7 |
Circuit breaker closing and opening speed measurement |
|
8 |
Travel-time, Coil current-time curve of circuit breaker operation measurement |
|
9 |
Travel and clearance of circuit breaker measurement |
|
10 |
Variable DC circuit breaker operation power supply |
|
11 |
Closing arc resistance value and connected time measurement |
|
12 |
Closing time and opening time of graphite circuit breaker measurement |
|
13 |
Print test results by internal micro printers |
Circuit breaker analyzer technical index:
|
1 |
Time measurement range: 6000ms, resolution 0.1ms Time measurement error <1%RDG+0.2ms |
|
2 |
Speed measurement: Range 2m/s resolution 0.01m/s max error<0.1m/s Range 20m/s resolution 0.01m/s max error<0.2m/s |
|
3 |
Travel measurement: Range 50.0mm resolution 0.1mm max error<1%RDG+0.1%FS Range 300.0mm resolution 1mm max error<1%RDG+0.1%FS Range 600.0mm resolution 1mm max error<1%RDG+0.1%FS |
|
4 |
Coil current measurement range 20.00A, resolution 0.01A, error 2%+0.2%FS |
|
5 |
Closing resistance value measurement range: 100~10000ohm, error: 5%RDG |
|
6 |
DC Power out: DC30V~250V/20A (instantaneous) |
|
7 |
Power supply: AC220V±10% 50Hz±10% |
|
8 |
Temperature:-10~40°Chumidity: <80% |
|
9 |
Size: 360mm*280mm*300mm Weight: 10kg |
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| HYBC-901 Transformer Ratio Meter | Transformer ratio meter Itistotestvoltageratio,vector,polarity,ratioerrorofcurrenttransformerandvoltagetransformer. Transformer turns ratio met... | |
| HYGS Tan Delta Tester | 1PowerFactor Testerapplication HYGS automatic tangent delta tester is applied to measure the dielectric loss and capacitor value of insulation mat... | |
| HYKC-2000 On Load Tap Changer Ohmmeter Analyzer | 1.Introduction On load tap changer analyzer HYKC-2000 is mainly applied to test transient time, transition waveform, transition resistance, sync... | |
| Dry Type Hipot Tester | Introduction HIPOT tester is applied to test the insulation ability of electric power equipments and insulation materials at power frequency high v... | |
| SLQ с первичный ток испытаний инъекции установить | Введение: SLQ с первичным током комплект испытания впрыски высокого текущего инструмента генератор. Он применяется в трансформатор тока, испытание ... |
Похожие товары
| Air Permeability Tester STD- F8 | Продавец: Standard International Group (HK) Limited | The Air Permeability Tester is designed to quickly and accurately measure the breathability and p... | |
| Surface Performance Tester STD-FB4 - A | Продавец: Standard International Group (HK) Limited | Introduction TheSurface Tester analyzes finger movements-particularly, strokes-performed by arti... | |
| Compression Tester STD - FB3 - A | Продавец: Standard International Group (HK) Limited | TheCompression Tester analyzes hand movements-particularly, pushing with a finger-performed by ar... | |
| Single - Strand Bending Tester STD - FB2 - SH | Продавец: Standard International Group (HK) Limited | Standards ASTM A370. ASTM A416. ISO6934.4 The Single Fiber Bending Tester makes it possible to ... | |
| Bending Tester STD- FB2 - S | Продавец: Standard International Group (HK) Limited | Compliance Standards ASTM D790 (Plastics Flexural Properties) ISO 178 (Flexural Strength of Rig... |