High Precision Spectroradiometer Integrating Sphere System

LPCE-2 Integrating Sphere Spectroradiometer LED Testing System is for single LEDs and LED lighting products light measurement. LED's quality should be tested by checking its photometric, colorimetric and electrical parameters. According toCIE 177,CIE84,CIE-13.3,IES LM-79-19,Optical-Engineering,COMMISSION DELEGATED REGULATION (EU) 2019/2015,IESNA LM-63-2,IES-LM-80andANSI-C78.377,it recommends to using an array spectroradiometer with an integrating sphere to test SSL products. The LPCE-2 system is applied with LMS-9000C High Precision CCD Spectroradiometer or LMS-9500C Scientific Grade CCD Spectroradiometer, and A molding integrating sphere with holder base. This sphere is more round and the test result is more accruacy than the traditional integrating sphere.

Measures:
• Colorimetric: Chromaticity coordinates, CCT, Color Ratio, Peak Wavelength, Half Bandwidth, Dominant Wavelength, Color Purity, CRI, CQS, TM-30 (Rf, Rg), Spectrum Test
• Photometric: Luminous Flux, Luminous Efficiency, Radiant Power, EEI, Energy Efficiency Class, Pupil Flux, Pupil Flux Efficiency, Pupil Factor, Cirtopic Flux, Plant Growth Lamp PAR and PPF
• Electrical: Voltage, Current, Power, Power Factor, Displacement Factor, Harmonic
• LED Light Decay Test according to LM-80: Flux VS time, CCT VS time, CRI VS time, Power VS time, Power Factor VS time, Current VS time and Flux Efficiency VS time.

Option: The LPCE-2(LMS-9000C) or LPCE-2(LMS-9500C) work with a IS-1.5MTConstant Temperature Integrating SphereandTMP-8 Multiplex Temperature Testercan fully meetIES LM-82

High Precision LPCE-2(LMS-9000C) System Configuration (It is suitable for the Middle & Small Manufactory or General Test Lab):
High Precision CCD Spectroradiometer(LMS-9000C),Optical Fiber(CFO-1.5M),Digital Power Meter(LS2050B/LS2050C/LS2012),DC Power Source(DC Series),AC Power Source(LSP-500VARC or LSP-500VARC-Pst),Integrating Sphere(IS-1.5MA and IS-0.3M),Standard Light Source(SLS-50W and SLS-10W),19 Inch Cabinet(CASE-19IN). You can download the detail PDF here:LPCE-2 (LMS-9000C) High Precision CCD Spectroradiometer Integrating Sphere System Brochure

Specification:
• Spectral Wavelength Accuracy: ±0.3nm, Wavelength Reproducibility: ±0.1nm
• Sample Scanning Steps: ±0.1nm
• Accuracy of Chromaticity Coordinate (Δx, Δy): ±0.002 (under Standard A Lamp)
• Correlated Color Temperature CCT: 1,500K~100,000K, CCT Accuracy: ±0.3%
• Color Rendering Index Range: 0~100.0, Accuracy: ±(0.3%rd±0.3)
• Luminous Flux Range: 0.01-200,000lm; Photometric linear Accuracy: ±0.5%
• Stray light: <0.015%(600nm) and <0.03%(435nm)
• Integration Time: 0.1~10,000ms
• It can measure the temperatures inside and outside of integrating sphere
• Flux testing method: spectrum, photometric and spectrum with photometric revision
• The system includes the auxiliary lamp device and the software includes self-absorption function
• It can measure the temperatures inside and outside of integrating sphere
• Connect with PC via USB cable. The English version software can be run in Win7, Win8, Win10 and Win11 (The driver was Certificated by Microsoft)
• The LM-79 Photometric, Colorimetric and Electricity report can be exported PDF and LED Optical Maintenance test report can be exported Excel or PDF

LISUN Model LMS-9000C LMS-9000CUV-VIS LMS-9000CVIS-NIR
Wavelength 350-800nm 200-800nm 350-1050nm

Scientific Grade LPCE-2(LMS-9500C) System Configuration (It is suitable for the Big & Middle Manufactory or Third Party Test Lab):
Scientific Grade CCD Spectroradiometer(LMS-9500C),Optical Fiber(CFO-1.5M),Digital Power Meter(LS2050C),DC Power Source(DC Series),AC Power Source(LSP-500VARC or LSP-500VARC-Pst),Integrating Sphere(IS-1.5MA and IS-0.3M),Standard Light Source(SLS-50W and SLS-10W),19 Inch Cabinet(CASE-19IN). You can download the detail PDF here:LPCE-2 (LMS-9500C) Scientific Grade CCD Spectroradiometer Integrating Sphere System Brochure

Specification:
• CCD detector: Hamamatsu TE-cooled (Temp: -10°C ±0.05°C) high sensitivity back-thinned detector
• Spectral wavelength accuracy: ±0.2nm, Resolution: ±0.1nm, Sample scanning steps: ±0.1nm
• Accuracy of chromaticity coordinate (Δx, Δy): ±0.0015 (under Standard A Lamp)
• Correlated color temperature CCT: 1, 500K~100, 000K, CCT accuracy: ±0.2%
• Color rendering index range: 0~100.0, Accuracy: ±(0.3%rd±0.3)
• Photometric linear Accuracy: ±0.2%
• Stray light: <0.015%(600nm) and <0.03% (435nm)
• Integration time: 0.1ms-60s
• It can measure the temperatures inside and outside of integrating sphere
• Flux testing method: spectrum, photometric and spectrum with photometric revision
• The system includes the auxiliary lamp device and the software includes self-absorption function
• It can measure the temperatures inside and outside of integrating sphere
• Connect with PC via USB cable. The English version software can be run in Win7, Win8, Win10 and Win11 (The driver was Certificated by Microsoft)
• The LM-79 Photometric, Colorimetric and Electricity report can be exported PDF and LED Optical Maintenance test report can be exported Excel or PDF

LISUN Model LMS-9500C LMS-9500CUV-VIS LMS-9500CVIS-NIR
Wavelength 350-800nm 200-800nm 350-1050nm


Отправить запрос, связаться с поставщиком

Кому: Lisun Instruments Limited
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

CCD Spectroradiometer Integrating Sphere Compact System
CCD Spectroradiometer Integrating Sphere Compact System LPCE-3 is a CCD Spectroradiometer Integrating Sphere Compact System for LED Testing. It is suitable for single LED and LED luminaires’ photom...
Waterproof Test Machine for IPX1 to IPX8
Waterproof Test Machine for IPX1 to IPX8 JL-X waterproof test machine is according toIEC60529:1989 +A1:1999 +A2:2013 Degrees of protection provided by enclosures(IP Code),IEC60598, IEC6033...
Dustproof Testing Machine for IP5X and IP6X
Dustproof Testing Machine for IP5X and IP6X SC-015Dust-proof Test Chamber(Sand Dust Chamber) is applied to physical and other related performance tests for electronic and electrical products,...
Electrodynamic Vibration Generator Test Table
Electrodynamic Vibration Generator Test Table LVD-100KG/LVD-100KG-6DElectrodynamic Vibration Generator Test Table is according toIEC 60068, IEC68-2-6,JJG189-97,GB/T13309-91, GB2423 and other re...
EMI Receiver System
EMI Receiver System EMI receiver system for EMI (Electromagnetic Interference) radiation conduction or conducted emissions testing. The EMI-9KB EMI receiver is produce...
Все товары поставщика

Похожие товары

Электронная окулярная камера MECHANIC MEC 4K 2K HD для стереомикроскопа
Электронная окулярная камера MECHANIC MEC 4K 2K HD для стереомикроскопа Продавец: ШЭНЬЧЖЭНЬСКАЯ ТЕХНОЛОГИЯ PHONEFIX, LTD (КИТАЙСКИЙ PHONEFIX) Описание Электронная окулярная камера Mechanic MEC 2K/2K PRO/4K HD может превратить бинокулярный ...
Цифровой мультиметр Fluke 15B+ 17B+ 18B+, тестер напряжения и частоты
Цифровой мультиметр Fluke 15B+ 17B+ 18B+, тестер напряжения и частоты Продавец: Шэньчжэнь Weike Repair Technology Co., Ltd. Полупрозрачная/полностью прозрачная/молочно-белая/светло-желтая паяльная паста iFixes 10CC, не со...
HTT-02 Hot Tack Tester
HTT-02 Hot Tack Tester Продавец: Cell Instruments Co., Ltd The HTT-02 Hot Tack Testeris specifically designed to assess this property by measuring the stren...
SPC-01 Stretch Film Peeling Cling Tester
SPC-01 Stretch Film Peeling Cling Tester Продавец: Cell Instruments Co., Ltd The SPC-01 Stretch Film Peeling Cling Testermeasures the adhesion between two layers of stretch f...
FTT-01 Film Thickness Tester
FTT-01 Film Thickness Tester Продавец: Cell Instruments Co., Ltd The FTT-01 FilmThickness Testerutilizes a mechanical scanning technique to measure the thickness ...