Bettersizer ST
The Bettersizer ST is an automated laser diffraction laser scattering particle size distribution analyzerdesigned for industrial quality control. Its patented DLOS (Dual Lens Optical System) guarantees the instrument to provide consistent and reliable particle size distribution results. The SOP (Standard Operating Procedure) and automated analysis procedures are designed to help you save valuable time for quality inspection. Skip complex operations with Bettersizer ST: Simply click "Start", add the sample, and Bettersizer ST will provide the particle size distribution analysis for you.
Measurement: Particle size
Particle size range: 0.1 to 1000µm
Dispersion type: Wet
Technology: Laser diffraction
Analysis: Mie scattering theory and Fraunhofer diffraction theory
Detector: 86 high-speed photodetectors (forward, lateral and backward arrangements)
Measuring angle: 0.031-159°
Download Brochure Request Demo Self-Installation
Application Notes
Measuring Particle Size Distribution of Gypsum Using Laser Diffraction
03 Sep 2021
Application of Laser Particle Size Analyzer in Quality Inspection of Silicon Carbide Abrasive Grains
07 Sep 2021
Analysis of Particle Size Distribution of Ceramic Powder Based on Laser Diffraction
10 Sep 2021
Measuring Particle Size Distribution of Calcium Carbonate Powders with Laser Diffraction Method
14 Sep 2021
Inspect the Quality of Pesticides with Laser Diffraction Particle Size Analyzer
16 Sep 2021
FeaturesSOPDLOSTechnologySpecificationCustomer StoryInquiry
EXCELLENT ACCURACY
Accuracy Verification of Standards
Duke standard samples were measured separately by the Bettersizer ST laser particle sizer, showing the distribution peak in the correct position and narrow distribution with high accuracy.
The red line is the nominal size range of standards ± 1.0%, and the black dots are the measured sizes. As shown in the figure, the measurement accuracy of Bettersizer ST laser particle sizer for standards is within 1%.
OUTSTANDING REPEATABILITY
Exceptional repeatability provided by Bettersizer ST laser particle sizer ensures the reliability of the results. Rapid measurements with consistent and reliable results can ease your workload on quality control.
Excellent Repeatability From: - Stability of signal transmission systems - Efficient dispersion system - Automatic alignment keeps the instrument always in optimum condition - Signal acquiring rate up to 3500 times/second
Repeatability Tests
The outstanding repeatability of Bettersizer ST, demonstrated by the following two consecutive tests.
Legendary Ease-of-Use
The Bettersize software provides various functions that greatly reduce your workload.
Ⅰ . Intuitive Software
Ⅱ . Intelligent Data Evaluation for Quality Control
Ⅲ . Performance Validation
Ⅳ . System Inspection
Cost-Efficiency & Robustness
Outstanding Robustness
- Integrated casting of the bottom plate to protect the instrument
- Accurate measurements can be achieved even after a robustness test
- Long-life fiber semiconductor laser source
- Durable circulation tank with casted stainless steel
- Power-adjustable ultrasonic disperser with dry run protection
Compact Design
- Save valuable workspace for factories and laboratories with an internal wet dispersion system
- The DLOS ensures result accuracy and reliability, while avoiding folding optics that are susceptible to misalignment
Simple Maintenance
- Simple disassembly of sample cells allows a quick cleaning, which can be easily accessed without professional tools and excessive clean formulations
- Auto-cleaning function for the circulation tank eases the maintenance work greatly
- Auto-cleaning process can be easily customized in the software
Low Cost of Ownership
- Entry-level price for laser particle size measurement units
- A measurement range that covers most applications can be achieved with DLOS without additional cost for a second laser source
If you want to know more details of granulometry test, please visit our website.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
BeDensi T Series | Tapped Density Meter BeDensi T series Tapped Density Meter Apparatus includes BeDensi T1 (one cylinder), BeDensi T2 (two cylinders) and BeDensi T3 ... | |
BeDensi T Series | TapDensity Meter BeDensi T series tapped bulk density apparatusincludes BeDensi T1 (one cylinder), BeDensi T2 (two cylinders) and BeDensi T3 (thre... | |
Bettersizer ST | Bettersizer ST The Bettersizer ST is an automated laser scattering particle size distribution analyzerdesigned for industrial quality control. I... | |
Nanoptic 90 Plus | The Nanoptic 90 Plus (nanoparticle sizer) is an optical detection system newly designed to measure the particle size and size distribution of nanop... | |
Dynamic Image Analysis | Most particle size measurement techniquesare based on the assumption of spherical shaped particles. This hypothesis leads to significant errors in ... |
Похожие товары
FNAC-28 2 IN 1 Type-C USB Tester Voltage Current Power Meter | Продавец: Phonefix | FNIRSI FNAC-28 Multifunctional 2 in 1 Type-C USB Tester Digital Voltmeter Ammeter Amperimetor Vol... | |
WF-EDU-02 Motor & Propeller Test Kit | Продавец: Wing Flying Technologies Co., Ltd | WF-EDU-02 Motor & Propeller Test Kit Product Description Motor & Propeller Test Kitsare... | |
WF-EDU-01 Motor and Propeller Test Kit | Продавец: Wing Flying Technologies Co., Ltd | WF-EDU-01 Motor and Propeller Test Kit Product Description Suggested Propulsion system ... | |
WF-EN-50 Engine Test Bench | Продавец: Wing Flying Technologies Co., Ltd | Suggested Engine 110cc-350cc Engine Max Hanging Type Engine 20kg ... | |
WF-EN-15 Engine Test Bench | Продавец: Wing Flying Technologies Co., Ltd | WF-EN-15 Engine Test Bench Product Description Suggested Engine 110cc Engine ... |